Different impact factors for accurate oscillometric blood pressure measurement between sinus rhythm and atrial fibrillation

被引:8
|
作者
Xie, Feng [1 ]
Xu, Jinsong [2 ]
Liu, Huan [2 ]
Li, Xiaozhong [2 ]
Wu, Yanqing [2 ]
Su, Hai [2 ]
机构
[1] JiangXi Pingxiang Peoples Hosp, Dept Cardiovasc Med, Pingxiang, Peoples R China
[2] Nanchang Univ, Affiliated Hosp 2, Dept Cardiovasc Med, Nanchang, Jiangxi, Peoples R China
关键词
AGE;
D O I
10.1038/s41371-021-00512-9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This study was conducted to evaluate whether the impact factor on the accuracy of oscillometric blood pressure (BP) is different between the patients with atrial affiliation (AF) and sinus rhythm (SR). This study included 124 AF patients and 98 SR patients who underwent coronary arteriography. Upper arm oscillometric and intro-aortic BP were simultaneously measured three times, and the averages were recorded as final values, respectively. The difference between oscillometric and intro-aortic BP was recorded as delta BP. For reducing the influence of baseline BP on delta BP, a percentage difference (PD-BP) was calculated with the formula: PD-BP = delta BP/intro-aortic BP x 100%. The oscillometric SBP and DBP levels slightly underestimated intro-aortic BP (by 2.2/1.6 mmHg) in the SR group, but significantly underestimated (by 5.8/4.8 mmHg) in the AF group. Age was negatively correlated with delta SBP and positively with delta DBP in SR patients, but not correlated in AF patients. Otherwise, ventricular rate (VR) was negatively correlated with delta SBP or delta DBP in AF, which indicated that the accuracy of oscillometric BP declined as the VR increased. With intro-aortic BP as reference, the accuracy of oscillometric BP in AF patients is lower than SR patients. Meanwhile, age may impact the oscillometric BP accuracy in SR patients, but VR may impact that in AF patients.
引用
收藏
页码:785 / 790
页数:6
相关论文
共 50 条
  • [31] The impact of atrial defibrillators on the natural history of persistent atrial fibrillation. Does sinus rhythm beget more sinus rhythm?
    Spurrell, PAR
    Mitchell, ARJ
    Kamalvand, K
    Topham, A
    Sulke, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 95A - 96A
  • [32] Restoring Sinus Rhythm Results in Blood Pressure Reduction in Patients with Persistent Atrial Fibrillation and a History of Hypertension
    Sanders, Natalie A.
    Bertolone, Cristina
    Jetter, Tawni L.
    Wasmund, Stephen L.
    Croci, Francesco
    Solano, Alberto
    Brignole, Michele
    Hamdan, Mohamed H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (07) : 722 - 726
  • [33] Systolic blood pressure increases in patients with atrial fibrillation regaining sinus rhythm after electrical cardioversion
    Olbers, Joakim
    Jacobson, Ellen
    Viberg, Fredrik
    Witt, Nils
    Ljungman, Petter
    Rosenqvist, Marten
    Ostergren, Jan
    JOURNAL OF CLINICAL HYPERTENSION, 2019, 21 (03): : 363 - 368
  • [34] The Impact of Elevated Left Atrial Pressure in Sinus Rhythm After Cardioversion on Outcomes After Catheter Ablation for Atrial Fibrillation
    Kishima, Hideyuki
    Mine, Takanao
    Takahashi, Satoshi
    Ashida, Kenki
    Ishihara, Masaharu
    Masuyama, Tohru
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (07) : 813 - 819
  • [35] Accuracy of oscillometric blood pressure monitors for the detection of atrial fibrillation: a systematic review
    Verberk, Willem J.
    de Leeuw, Peter W.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (06) : 635 - 640
  • [36] A trial of three non-invasive blood pressure monitors compared with invasive blood pressure assessment in atrial fibrillation and sinus rhythm
    Eysenck, William
    Ammar, Ahmed
    Kanthasamy, Vijaya
    Freemantle, Nick
    Veasey, Rick A.
    Patel, Nikhil R.
    Furniss, Stephen S.
    Sulke, Neil
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2019, 73 (12)
  • [37] Measurement of blood pressure in people with atrial fibrillation
    Clark, Christopher E.
    McDonagh, Sinead T. J.
    McManus, Richard J.
    Chapman, N.
    Chowienczyk, P.
    Denver, E.
    Lacy, P.
    Lewis, P.
    Martin, U.
    Neary, A.
    Sheppard, J.
    JOURNAL OF HUMAN HYPERTENSION, 2019, 33 (11) : 763 - 765
  • [38] Measurement of blood pressure in people with atrial fibrillation
    Christopher E. Clark
    Sinead T. J. McDonagh
    Richard J. McManus
    Journal of Human Hypertension, 2019, 33 : 763 - 765
  • [39] BLOOD PRESSURE IN ATRIAL FIBRILLATION AND IN SINUS RHYTHM DURING 24 HOUR AMBULATORY BLOOD PRESSURE MONITORING: DATA FROM THE TEMPLAR PROJECT
    Lundwall, Kristina
    Kahan, Thomas
    Omboni, Stefano
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E9 - E9
  • [40] Comparison of voltages between atria: differences in sinus rhythm and atrial fibrillation
    Bates, Alexander P.
    Paisey, John
    Yue, Arthur
    Banks, Phil
    Roberts, Paul R.
    Ullah, Waqas
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) : 649 - 656