Accuracy of manual entry of drug administration data into an anesthesia information management system

被引:2
|
作者
Avidan, Alexander [1 ]
Dotan, Koren [1 ]
Weissman, Charles [1 ]
Cohen, Matan J. [2 ,3 ]
Levin, Phillip D. [1 ]
机构
[1] Hadassah Hebrew Univ Med Ctr, Dept Anesthesiol & Crit Care Med, IL-91120 Jerusalem, Israel
[2] Hadassah Hebrew Univ Med Ctr, Ctr Qual & Clin Safety, IL-91120 Jerusalem, Israel
[3] Hadassah Hebrew Univ Med Ctr, Dept Clin Microbiol & Infect Dis, IL-91120 Jerusalem, Israel
关键词
COMPLETENESS; FUTURE;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Data on drug administration are entered manually into anesthesia information management systems (AIMS). This study examined whether these data are accurate regarding drug name, dose administered, and time of administration, and whether the stage of anesthesia influences data accuracy. Real-time observational data on drug administration during elective operations were compared with computerized information on drug administration entered by anesthesiologists. A trained observer (K.D.) performed the observations. Data were collected during 57 operations which included 596 separate occasions of drug administration by 22 anesthesiologists. No AIMS records were found for 90 (15.1%) occasions of drug administration (omissions), while there were 11 (1.8%) AIMS records where drug administration was not observed. The AIMS and observer data matched for drug name on 495 of 596 (83.1%) occasions, for dose on 439 of 495 (92.5%) occasions, and for time on 476 of 495 (96.2%) occasions. Amongst the 90 omitted records, 34 (37.8%) were for vasoactive drugs with 24 (27.7%) for small doses of hypnotics. Omissions occurred mostly during maintenance: 50 of 153 (24.6%), followed by induction: 30 of 325 (9.2%) and emergence: 10 of 57 (17.5%) (P < 0.001). Time and dose inaccuracies occurred mainly during induction, followed by maintenance and emergence; time inaccuracies were 7/325 (8.3%), 10/203 (4.9%), and 0/57 (0%), respectively (P = 0.07), and dose inaccuracies were 15/325 (4.6%), 3/203 (1.5%), and 1/57 (1.7%), respectively (P = 0.11). The range of accuracy varies when anesthesiologists manually enter drug administration data into an AIMS. Charting omissions represent the largest cause of inaccuracy, principally by omissions of records for vasopressors and small doses of hypnotic drugs. Manually entered drug administration data are not without errors. Accuracy of entering drug administration data remains the responsibility of the anesthesiologist.
引用
收藏
页码:979 / 985
页数:7
相关论文
共 50 条
  • [31] Database Quality and Access Issues Relevant to Research Using Anesthesia Information Management System Data
    Epstein, Richard H.
    Dexter, Franklin
    ANESTHESIA AND ANALGESIA, 2018, 127 (01): : 105 - 114
  • [32] Numbers of Simultaneous Turnovers Calculated from Anesthesia or Operating Room Information Management System Data
    Dexter, Franklin
    Marcon, Eric
    Aker, John
    Epstein, Richard H.
    ANESTHESIA AND ANALGESIA, 2009, 109 (03): : 900 - 905
  • [33] An observational study of anesthesia record completeness using an anesthesia information management system
    Driscoll, William D.
    Columbia, Mary Ann
    Peterfreund, Robert A.
    ANESTHESIA AND ANALGESIA, 2007, 104 (06): : 1454 - 1461
  • [34] A System for Anesthesia Drug Administration Using Barcode Technology: The Codonics Safe Label System and Smart Anesthesia Manager™
    Jelacic, Srdjan
    Bowdle, Andrew
    Nair, Bala G.
    Kusulos, Dolly
    Bower, Lynnette
    Togashi, Kei
    ANESTHESIA AND ANALGESIA, 2015, 121 (02): : 410 - 421
  • [35] Completeness of manual data recording in the anaesthesia information management system: A retrospective audit of 1000 neurosurgical cases
    Palaniswamy, Sangeetha R.
    Jain, Vikyath
    Chakrabarti, Dhritiman
    Bharadwaj, Supama
    Sriganesh, Kamath
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (10) : 797 - +
  • [36] EZ-Entry: A clinical data management system
    Gao, Qing-Bin
    Kong, Yu
    Fu, Zheng
    Lu, Han
    Wu, Cheng
    Jin, Zhi-Chao
    He, Jia
    COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (09) : 1042 - 1044
  • [37] INCORPORATING DIAGNOSIS INFORMATION INTO A MANUAL DRUG-USE REVIEW SYSTEM
    KNAPP, DA
    BRANDON, BM
    KNAPP, DE
    KLEIN, LS
    PALUMBO, FB
    SHAH, R
    JOURNAL OF THE AMERICAN PHARMACEUTICAL ASSOCIATION, 1977, 17 (02): : 103 - 106
  • [39] A chromatography data system for information management
    Schibler, JA
    AMERICAN LABORATORY, 2000, 32 (06) : 52 - +
  • [40] Incidence of Artifacts and Deviating Values in Research Data Obtained from an Anesthesia Information Management System in Children
    Hoorweg, Anne-lee J.
    Pasma, Wietze
    van Wolfswinkel, Leo
    de Graaff, Jurgen C.
    ANESTHESIOLOGY, 2018, 128 (02) : 293 - 304