Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T

被引:4
|
作者
McElroy, Sarah [1 ]
Ferrazzi, Giulio [2 ]
Nazir, Muhummad Sohaib [1 ]
Evans, Carl [1 ]
Ferreira, Joana [1 ]
Bosio, Filippo [1 ]
Mughal, Nabila [1 ]
Kunze, Karl P. [3 ]
Neji, Radhouene [1 ,3 ]
Speier, Peter [4 ]
Stab, Daniel [5 ]
Ismail, Tevfik F. [1 ]
Masci, Pier Giorgio [1 ]
Villa, Adriana D. M. [1 ]
Razavi, Reza [1 ]
Chiribiri, Amedeo [1 ]
Roujol, Sebastien [1 ]
机构
[1] Kings Coll London, Fac Life Sci & Med, Sch Biomed Engn & Imaging Sci, London, England
[2] IRCCS San Camillo Hosp, Venice, Italy
[3] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[4] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[5] Siemens Healthcare Ltd, MR Res Collaborat, Melbourne, Vic, Australia
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
compressed sensing; myocardial perfusion; simultaneous multi-slice; CORONARY-ARTERY-DISEASE; ISCHEMIC BURDEN; NONINVASIVE DETECTION; STRESS PERFUSION; HEART; ECHO; MRI; CMR;
D O I
10.1002/mrm.29229
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 x 1.4 mm(2)) at 1.5T. Methods A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 x 1.4 mm(2)) and a conventional three-slice sequence with conventional spatial resolution (1.9 x 1.9 mm(2)) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. Results Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 +/- 0.6 vs. 2.7 +/- 0.2, p = 0.8) or perceived SNR (2.8 +/- 0.3 vs. 2.7 +/- 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 +/- 0.08 vs 0.32 +/- 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 +/- 0.04 vs. 0.11 +/- 0.03, p = 0.84). Conclusion SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.
引用
收藏
页码:663 / 675
页数:13
相关论文
共 50 条
  • [41] Comparison of wideband steady-state free precession and T2-weighted fast spin echo in spine disorder assessment at 1.5 and 3 T
    Danagoulian, Giovanna S.
    Qin, Lei
    Nayak, Krishna S.
    Colen, Rivka R.
    Mukundan, Srinivasan, Jr.
    Harris, Mitchell B.
    Jolesz, Ferenc A.
    Shankaranarayanan, Ajit
    Copen, William A.
    Schmidt, Ehud J.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1527 - 1535
  • [42] Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    Alfakih, K
    Plein, S
    Thiele, H
    Jones, T
    Ridgway, JP
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 323 - 329
  • [43] T2-prepared balanced steady-state free precession (bSSFP) for quantifying whole-blood oxygen saturation at 1.5T
    Rodriguez-Soto, Ana E.
    Abdulmalik, Osheiza
    Langham, Michael C.
    Schwartz, Nadav
    Lee, Hyunyeol
    Wehrli, Felix W.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1893 - 1900
  • [44] Ultrahigh-Resolution Imaging of the Human Brain with Phase-Cycled Balanced Steady-State Free Precession at 7 T
    Zeineh, Michael M.
    Parekh, Mansi B.
    Zaharchuk, Greg
    Su, Jason H.
    Rosenberg, Jarrett
    Fischbein, Nancy J.
    Rutt, Brian K.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 278 - 289
  • [45] Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences
    Kunz, RP
    Oellig, F
    Krummenauer, F
    Oberholzer, K
    Romaneehsen, B
    Vomweg, TW
    Horstick, G
    Hayes, C
    Thelen, M
    Kreitner, KF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) : 140 - 148
  • [46] Cardiovascular magnetic resonance evaluation of left ventricular peak filling rate using steady-state free precession and phase contrast sequences
    Komi, Shotaro
    Inoue, Yusuke
    Hata, Hirofumi
    Nakajima, Ai
    Miyatake, Hiroki
    SPRINGERPLUS, 2016, 5
  • [48] Assessment of myocardial perfusion for detection of coronary artery stenoses by steady-state, free-precession magnetic resonance first-pass imaging
    Merkle, Nico
    Woehrle, Jochen
    Grebe, Olaf
    Nusser, Thorsten
    Kunze, Markus
    Kestler, Hans A.
    Kochs, Matthias
    Hombach, Vinzenz
    HEART, 2007, 93 (11) : 1381 - 1385
  • [49] Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance
    Buechel, Emanuela Valsangiacomo
    Kaiser, Thomas
    Jackson, Clare
    Schmitz, Achim
    Kellenberger, Christian J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
  • [50] MR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence
    Germain, D
    Vahala, E
    Ehnholm, GJ
    Vaara, T
    Ylihautala, M
    Savart, M
    Laurent, A
    Tanttu, J
    Saint-Jalmes, H
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 940 - 947