Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T

被引:4
|
作者
McElroy, Sarah [1 ]
Ferrazzi, Giulio [2 ]
Nazir, Muhummad Sohaib [1 ]
Evans, Carl [1 ]
Ferreira, Joana [1 ]
Bosio, Filippo [1 ]
Mughal, Nabila [1 ]
Kunze, Karl P. [3 ]
Neji, Radhouene [1 ,3 ]
Speier, Peter [4 ]
Stab, Daniel [5 ]
Ismail, Tevfik F. [1 ]
Masci, Pier Giorgio [1 ]
Villa, Adriana D. M. [1 ]
Razavi, Reza [1 ]
Chiribiri, Amedeo [1 ]
Roujol, Sebastien [1 ]
机构
[1] Kings Coll London, Fac Life Sci & Med, Sch Biomed Engn & Imaging Sci, London, England
[2] IRCCS San Camillo Hosp, Venice, Italy
[3] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[4] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[5] Siemens Healthcare Ltd, MR Res Collaborat, Melbourne, Vic, Australia
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
compressed sensing; myocardial perfusion; simultaneous multi-slice; CORONARY-ARTERY-DISEASE; ISCHEMIC BURDEN; NONINVASIVE DETECTION; STRESS PERFUSION; HEART; ECHO; MRI; CMR;
D O I
10.1002/mrm.29229
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 x 1.4 mm(2)) at 1.5T. Methods A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 x 1.4 mm(2)) and a conventional three-slice sequence with conventional spatial resolution (1.9 x 1.9 mm(2)) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. Results Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 +/- 0.6 vs. 2.7 +/- 0.2, p = 0.8) or perceived SNR (2.8 +/- 0.3 vs. 2.7 +/- 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 +/- 0.08 vs 0.32 +/- 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 +/- 0.04 vs. 0.11 +/- 0.03, p = 0.84). Conclusion SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.
引用
收藏
页码:663 / 675
页数:13
相关论文
共 50 条
  • [21] Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging
    Peter Hunold
    Stefan Maderwald
    Holger Eggebrecht
    Florian M. Vogt
    Jörg Barkhausen
    European Radiology, 2004, 14 : 409 - 416
  • [22] HIGH-RESOLUTION RENAL DIFFUSION IMAGING USING A MODIFIED STEADY-STATE FREE PRECESSION SEQUENCE
    DING, SJ
    TRILLAUD, H
    YONGBI, M
    ROLETT, EL
    WEAVER, JB
    DUNN, JF
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 586 - 595
  • [23] Phase-Incremented Steady-State Free Precession as an Alternate Route to High-Resolution NMR
    He, Tian
    Zur, Yuval
    Montrazi, Elton T.
    Frydman, Lucio
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2024, 146 (06) : 3615 - 3621
  • [24] Dynamic and steady-state oxygen-dependent lung relaxometry using inversion recovery ultra-fast steady-state free precession imaging at 1.5 T
    Bauman, Grzegorz
    Pusterla, Orso
    Santini, Francesco
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 839 - 845
  • [25] Balanced steady-state free precession with parallel imaging gives distortion-free fMRI with high temporal resolution
    Chappell, Michael
    Haberg, Asta K.
    Kristoffersen, Anders
    MAGNETIC RESONANCE IMAGING, 2011, 29 (01) : 1 - 8
  • [26] Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession
    Thiele, H
    Paetsch, I
    Schnackenburg, B
    Bornstedt, A
    Grebe, O
    Wellnhofer, E
    Schuler, G
    Fleck, E
    Nagel, E
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (03) : 327 - 339
  • [27] Left Ventricular Scar Detection in Hypertrophic Cardiomyopathy: A Radiomic Analysis of Steady-state Free Precession Cine Cardiac MRI
    Mancio, Jennifer
    Pashakhanloo, Farhad
    El-Rewaidy, Hossam
    Rowen, Ethan
    Manning, Warren J.
    Maron, Martin S.
    Nezafat, Reza
    CIRCULATION, 2019, 140
  • [28] Myocardial first pass perfusion: Steady-state free precession versus spoiled gradient echo and segmented echo planar imaging
    Wang, Y
    Moin, K
    Akinboboye, O
    Reichek, N
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1123 - 1129
  • [29] Feasibility of balanced steady-state free precession sequence at 1.5T for the evaluation of hepatic steatosis in obese children and adolescents
    Zhang, Hong-xi
    Fu, Jun-fen
    Lai, Can
    Tian, Feng-yu
    Su, Xiao-li
    Huang, Ke
    EUROPEAN RADIOLOGY, 2018, 28 (11) : 4479 - 4487
  • [30] High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisitiona)
    Wu, Pei-Hsin
    Tsai, Ping-Huei
    Wu, Ming-Long
    Chuang, Tzu-Chao
    Shih, Yi-Yu
    Chung, Hsiao-Wen
    Huang, Teng-Yi
    MEDICAL PHYSICS, 2013, 40 (12)