Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T

被引:4
|
作者
McElroy, Sarah [1 ]
Ferrazzi, Giulio [2 ]
Nazir, Muhummad Sohaib [1 ]
Evans, Carl [1 ]
Ferreira, Joana [1 ]
Bosio, Filippo [1 ]
Mughal, Nabila [1 ]
Kunze, Karl P. [3 ]
Neji, Radhouene [1 ,3 ]
Speier, Peter [4 ]
Stab, Daniel [5 ]
Ismail, Tevfik F. [1 ]
Masci, Pier Giorgio [1 ]
Villa, Adriana D. M. [1 ]
Razavi, Reza [1 ]
Chiribiri, Amedeo [1 ]
Roujol, Sebastien [1 ]
机构
[1] Kings Coll London, Fac Life Sci & Med, Sch Biomed Engn & Imaging Sci, London, England
[2] IRCCS San Camillo Hosp, Venice, Italy
[3] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[4] Siemens Healthcare GmbH, Magnet Resonance, Erlangen, Germany
[5] Siemens Healthcare Ltd, MR Res Collaborat, Melbourne, Vic, Australia
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
compressed sensing; myocardial perfusion; simultaneous multi-slice; CORONARY-ARTERY-DISEASE; ISCHEMIC BURDEN; NONINVASIVE DETECTION; STRESS PERFUSION; HEART; ECHO; MRI; CMR;
D O I
10.1002/mrm.29229
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 x 1.4 mm(2)) at 1.5T. Methods A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 x 1.4 mm(2)) and a conventional three-slice sequence with conventional spatial resolution (1.9 x 1.9 mm(2)) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. Results Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 +/- 0.6 vs. 2.7 +/- 0.2, p = 0.8) or perceived SNR (2.8 +/- 0.3 vs. 2.7 +/- 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 +/- 0.08 vs 0.32 +/- 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 +/- 0.04 vs. 0.11 +/- 0.03, p = 0.84). Conclusion SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.
引用
收藏
页码:663 / 675
页数:13
相关论文
共 50 条
  • [1] Combined simultaneous multislice bSSFP and compressed sensing for first-pass myocardial perfusion at 1.5 T with high spatial resolution and coverage
    McElroy, Sarah
    Ferrazzi, Giulio
    Nazir, Muhummad Sohaib
    Kunze, Karl P.
    Neji, Radhouene
    Speier, Peter
    Stab, Daniel
    Forman, Christoph
    Razavi, Reza
    Chiribiri, Amedeo
    Roujol, Sebastien
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3103 - 3116
  • [2] Simultaneous multi-slice steady-state free precession myocardial perfusion with iterative reconstruction and integrated motion compensation
    McElroy, Sarah
    Kunze, Karl P.
    Nazir, Muhummad Sohaib
    Speier, Peter
    Stab, Daniel
    Villa, Adriana D. M.
    Yazdani, Momina
    Vergani, Vittoria
    Roujol, Sebastien
    Neji, Radhouene
    Chiribiri, Amedeo
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [3] Fat in left ventricular myocardium assessed by steady-state free precession pulse sequences
    Giovanni Donato Aquaro
    Gaetano Nucifora
    Laura Pederzoli
    Elisabetta Strata
    Daniele De Marchi
    Giancarlo Todiere
    Barison Andrea
    Alessandro Pingitore
    Massimo Lombardi
    The International Journal of Cardiovascular Imaging, 2012, 28 : 813 - 821
  • [4] Fat in left ventricular myocardium assessed by steady-state free precession pulse sequences
    Aquaro, Giovanni Donato
    Nucifora, Gaetano
    Pederzoli, Laura
    Strata, Elisabetta
    De Marchi, Daniele
    Todiere, Giancarlo
    Andrea, Barison
    Pingitore, Alessandro
    Lombardi, Massimo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 813 - 821
  • [5] Cardiac balanced steady-state free precession MRI at 0.35 T: a comparison study with 1.5 T
    Rashid, Shams
    Han, Fei
    Gao, Yu
    Sung, Kyunghyun
    Cao, Minsong
    Yang, Yingli
    Hu, Peng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (07) : 627 - 636
  • [6] On the sensitivity of steady-state free precession myocardial blood-oxygen-level-dependent MRI at 1.5 T: theory and experiment
    Xiangzhi Zhou
    Richard Tang
    Rachel Klein
    Debiao Li
    Rohan Dharmakumar
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [7] Sensitivity and specificity of high-resolution balanced steady-state free precession fMRI at high field of 9.4 T
    Park, Sung-Hong
    Kim, Tae
    Wang, Ping
    Kim, Seong-Gi
    NEUROIMAGE, 2011, 58 (01) : 168 - 176
  • [8] Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T
    Muhummad Sohaib Nazir
    Radhouene Neji
    Peter Speier
    Fiona Reid
    Daniel Stäb
    Michaela Schmidt
    Christoph Forman
    Reza Razavi
    Sven Plein
    Tevfik F. Ismail
    Amedeo Chiribiri
    Sébastien Roujol
    Journal of Cardiovascular Magnetic Resonance, 20
  • [9] Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold
    Zwanenburg, JJM
    Kuijer, JPA
    Marcus, JT
    Heethaar, RM
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (04) : 722 - 730
  • [10] Validating the Gold-standard: Steady-State Free Precession Sequence for Assessment of Left Ventricular and Right Ventricular Mass
    Santos-Gallego, Carlos G.
    Njerve, Ida U.
    Ishikawa, Kiyotake
    Aguero, Jaime
    Vahl, Torsten
    Picatoste, Belen
    Hammoudi, Nadjib
    Najjar, Roger J.
    Fuster, Valentin
    Badimon, Juan
    Sanz, Javier
    CIRCULATION, 2014, 130