Contrast-Enhanced Ultrasound (CEUS) Identifies Perfusion Differences Between Tibial Fracture Unions and Non-Unions

被引:13
|
作者
Fischer, Christian [1 ]
Haug, Tabea [1 ]
Weber, Marc-Andre [2 ,3 ]
Kauczor, Hans-Ulrich [2 ]
Bruckner, Thomas [4 ]
Schmidmaier, Gerhard [1 ]
机构
[1] Heidelberg Univ Hosp, HTRG, Ctr Orthoped Trauma Surg & Spinal Cord Injury, Schlierbacher Landstr 200a, D-69118 Heidelberg, Germany
[2] Heidelberg Univ Hosp, Diagnost & Intervent Radiol, Heidelberg, Germany
[3] Univ Med Ctr Rostock, Inst Diagnost & Intervent Radiol, Rostock, Germany
[4] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2020年 / 41卷 / 01期
关键词
CEUS; fracture; non-union; tibia; osseus perfusion; NONUNION; RISK;
D O I
10.1055/a-0637-1679
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose To assess the value of CEUS in the evaluation of tibial fracture perfusion and its ability to differentiate between physiologic and abnormal fracture healing. Materials and Methods From 2014 to 2017, 107 patients with tibial fractures or tibial non- unions underwent CEUS examination. CEUS was performed at the regular follow-up examination 26 weeks after osteosynthesis or before nonunion surgery. Time-intensity curves (TICs) of the contrast enhancement in the fracture gap were generated, and volume parameters such as wash-in rate (WiR), peak enhancement (PE) and wash-in perfusion index ( WiPI) were quantified. Results A total of 34 patientsmet the inclusion criteria of this study, including 14 consolidated fractures, 12 aseptic non-unions and 8 infected non-unions. WiR, PE and WiPI showed significantly lower values in aseptic non-unions compared to unions (p = 0.009, 0.009, 0.012, resp.). In contrast, infected non-unions showed higher values of WiR, PE and WiPI when compared to unions (p = 0.034, 0.056, 0.029, resp.). Conclusion CEUS represents a feasible method in the assessment of tibial fracture perfusion. Perfusion differences between aseptic and infected tibial non-unions as well as healing tibial fractures could be detected. The deviation of physiologic fracture perfusion seems to be associated with disturbed osseous regeneration leading to non-union.
引用
收藏
页码:44 / 51
页数:8
相关论文
共 50 条
  • [31] The Value of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Perfusion Disturbances in Abdominal Wall Hernias Compared with Surgical and Histological Assessment
    Zadeh, Ehsan Safai
    Goerg, Christian
    Kuttkat, Phillip
    Dietrich, Christoph Frank
    Westhoff, Christina Carolin
    Rodepeter, Fiona
    Trenker, Corinna
    Goerg, Marvin
    Kirschbaum, Andreas
    Alhyari, Amjad
    DIAGNOSTICS, 2022, 12 (02)
  • [32] EFSUMB Technical Review - Update 2023: Dynamic Contrast-Enhanced Ultrasound (DCE-CEUS) for the Quantification of Tumor Perfusion
    Dietrich, Christoph F.
    Correas, Jean-Michel
    Cui, Xin-Wu
    Dong, Yi
    Havre, Roald Flesland
    Jenssen, Christian
    Jung, Ernst Michael
    Krix, Martin
    Lim, Adrian
    Lassau, Nathalie
    Piscaglia, Fabio
    ULTRASCHALL IN DER MEDIZIN, 2024, 45 (01): : 36 - 46
  • [33] The role of Bone Morphogenetic Protein-7 (Osteogenic Protein-1®) in the treatment of tibial fracture non-unions -: An overview of the use in Belgium
    Desmyter, Stefan
    Goubau, Yannick
    Benahmed, Nadia
    De Wever, Alain
    Verdonk, Rene
    ACTA ORTHOPAEDICA BELGICA, 2008, 74 (04): : 534 - 537
  • [34] Contrast-Enhanced Ultrasound Identifies Reduced Overall and Regional Renal Perfusion During Global Hypoxia in Piglets
    Brabrand, Knut
    de Lange, Charlotte
    Emblem, Kyrre E.
    Reinholt, Finn P.
    Saugstad, Ola Didrik
    Stokke, Eirik Schram
    Munkeby, Berit H.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (08) : 540 - 546
  • [35] Experience of an isolated use of low-intensity pulsed ultrasound therapy on fracture healing in established non-unions: a prospective case series
    Bawale, Rajesh
    Segmeister, Markus
    Sinha, Sanjay
    Shariff, Sajid
    Singh, Bijayendra
    JOURNAL OF ULTRASOUND, 2021, 24 (03) : 249 - 252
  • [36] Experience of an isolated use of low-intensity pulsed ultrasound therapy on fracture healing in established non-unions: a prospective case series
    Rajesh Bawale
    Markus Segmeister
    Sanjay Sinha
    Sajid Shariff
    Bijayendra Singh
    Journal of Ultrasound, 2021, 24 : 249 - 252
  • [37] Perfusion Patterns of Peripheral Pulmonary Granulomatous Lesions Using Contrast-Enhanced Ultrasound (CEUS) and Their Correlation with Immunohistochemically Detected Vascularization Patterns
    Safai Zadeh, Ehsan
    Keber, Corinna U.
    Dietrich, Christoph F.
    Westhoff, Christina C.
    Guenter, Christina
    Beutel, Bjoern
    Alhyari, Amjad
    Trenker, Corinna
    Goerg, Christian
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (03) : 565 - 574
  • [38] VueBox® perfusion analysis of contrast-enhanced ultrasound (CEUS) examinations in patients with primary hyperparathyroidism for preoperative detection of parathyroid gland adenoma
    da Silva, Natascha Platz Batista
    Jung, Ernst Michael
    Jung, Friedrich
    Schlitt, Hans J.
    Hornung, Matthias
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2018, 70 (04) : 423 - 431
  • [39] Perfusion Patterns of Peripheral Organizing Pneumonia (POP) Using Contrast-Enhanced Ultrasound (CEUS) and Their Correlation with Immunohistochemically Detected Vascularization Patterns
    Zadeh, Ehsan Safai
    Westhoff, Christina Carolin
    Keber, Corinna Ulrike
    Trenker, Corinna
    Dietrich, Christoph Frank
    Alhyari, Amjad
    Mohr, Charlotte Gabriele Luise
    Goerg, Christian
    DIAGNOSTICS, 2021, 11 (09)
  • [40] Perfusion patterns of peripheral pulmonary lesions in COVID-19 patients using contrast-enhanced ultrasound (CEUS) A case series
    Zadeh, Ehsan Safai
    Beutel, Bjoern
    Dietrich, Christoph Frank
    Keber, Corinna Ulrike
    Huber, Katharina Paulina
    Goerg, Christian
    Trenker, Corinna
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (11) : 2403 - 2411