Contrast-Enhanced Ultrasound (CEUS) Identifies Perfusion Differences Between Tibial Fracture Unions and Non-Unions

被引:13
|
作者
Fischer, Christian [1 ]
Haug, Tabea [1 ]
Weber, Marc-Andre [2 ,3 ]
Kauczor, Hans-Ulrich [2 ]
Bruckner, Thomas [4 ]
Schmidmaier, Gerhard [1 ]
机构
[1] Heidelberg Univ Hosp, HTRG, Ctr Orthoped Trauma Surg & Spinal Cord Injury, Schlierbacher Landstr 200a, D-69118 Heidelberg, Germany
[2] Heidelberg Univ Hosp, Diagnost & Intervent Radiol, Heidelberg, Germany
[3] Univ Med Ctr Rostock, Inst Diagnost & Intervent Radiol, Rostock, Germany
[4] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2020年 / 41卷 / 01期
关键词
CEUS; fracture; non-union; tibia; osseus perfusion; NONUNION; RISK;
D O I
10.1055/a-0637-1679
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose To assess the value of CEUS in the evaluation of tibial fracture perfusion and its ability to differentiate between physiologic and abnormal fracture healing. Materials and Methods From 2014 to 2017, 107 patients with tibial fractures or tibial non- unions underwent CEUS examination. CEUS was performed at the regular follow-up examination 26 weeks after osteosynthesis or before nonunion surgery. Time-intensity curves (TICs) of the contrast enhancement in the fracture gap were generated, and volume parameters such as wash-in rate (WiR), peak enhancement (PE) and wash-in perfusion index ( WiPI) were quantified. Results A total of 34 patientsmet the inclusion criteria of this study, including 14 consolidated fractures, 12 aseptic non-unions and 8 infected non-unions. WiR, PE and WiPI showed significantly lower values in aseptic non-unions compared to unions (p = 0.009, 0.009, 0.012, resp.). In contrast, infected non-unions showed higher values of WiR, PE and WiPI when compared to unions (p = 0.034, 0.056, 0.029, resp.). Conclusion CEUS represents a feasible method in the assessment of tibial fracture perfusion. Perfusion differences between aseptic and infected tibial non-unions as well as healing tibial fractures could be detected. The deviation of physiologic fracture perfusion seems to be associated with disturbed osseous regeneration leading to non-union.
引用
收藏
页码:44 / 51
页数:8
相关论文
共 50 条
  • [21] Perivascular Perfusion on Contrast-Enhanced Ultrasound (CEUS) Is Associated with Inflammation in Patients with Acute Deep Vein Thrombosis
    Kaspar, Mathias
    Imfeld, Stephan
    Partovi, Sasan
    Aschwanden, Markus
    Baldi, Thomas
    Dikkes, Alexander
    Vogt, Deborah R.
    Tsakiris, Dimitrios A.
    Staub, Daniel
    THROMBOSIS AND HAEMOSTASIS, 2017, 117 (11) : 2146 - 2155
  • [22] Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS)
    Philipp Lamby
    Friedrich Jung
    Stefanie Graf
    Lotte Schellenberg
    Johannes Falter
    Natascha Platz-da-Silva
    Stephan Schreml
    Lukas Prantl
    Ralf P. Franke
    Ernst M. Jung
    Scientific Reports, 7
  • [23] Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS)
    Lamby, Philipp
    Jung, Friedrich
    Graf, Stefanie
    Schellenberg, Lotte
    Falter, Johannes
    Platz-da-Silva, Natascha
    Schreml, Stephan
    Prantl, Lukas
    Franke, Ralf P.
    Jung, Ernst M.
    SCIENTIFIC REPORTS, 2017, 7
  • [24] Percutaneous Treatment of Malignant Liver Lesions: Evaluation of Success Using Contrast-Enhanced Ultrasound (CEUS) and Perfusion Software
    Wiesinger, Isabel
    Wiggermann, Philipp
    Zausig, Nicola
    Beyer, Lukas P.
    Salzberger, Bernd
    Stroszczynski, Christian
    Jung, Ernst Michael
    ULTRASCHALL IN DER MEDIZIN, 2018, 39 (04): : 440 - 447
  • [25] Intramuscular Perfusion Response in Delayed Onset Muscle Soreness (DOMS): A Quantitative Analysis with Contrast-Enhanced Ultrasound (CEUS)
    Kellermann, Marion
    Heiss, Rafael
    Swoboda, Bernd
    Gelse, Kolja
    Freiwald, Juergen
    Grim, Casper
    Nagel, Armin
    Uder, Michael
    Wildner, Dane
    Hotfiel, Thilo
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (11) : 833 - 841
  • [26] Quantitative analysis of tissue perfusion using contrast-enhanced transabdominal ultrasound (CEUS) in the evaluation of the severity of acute pancreatitis
    Golea, Adela
    Badea, Radu
    Socaciu, Mihai
    Diaconu, Brindusa
    Iacob, Daniela
    MEDICAL ULTRASONOGRAPHY, 2010, 12 (03) : 198 - 204
  • [27] A Preliminary Study of Contrast-Enhanced Ultrasound (CEUS) and Cytokine Expression Analysis (CEA) as Early Predictors for the Outcome of Tibial Non-Union Therapy
    Haubruck, Patrick
    Heller, Raban
    Tanner, Michael C.
    Daniel, Volker
    Schmidmaier, Gerhard
    Bolourchi, Farhoud
    Moghaddam, Arash
    Fischer, Christian
    DIAGNOSTICS, 2018, 8 (03)
  • [28] Perfusionsanalyse von Parotistumoren mittels kontrastverstärkter Sonographie (CEUS)Perfusion analysis in parotid gland tumors using contrast-enhanced ultrasound (CEUS)
    Maria Agnes Albers
    Julian Küstermeyer
    Hans-Jürgen Welkoborsky
    HNO, 2022, 70 (1) : 51 - 59
  • [29] Age-related differences in skeletal muscle microvascular response to exercise as detected by contrast-enhanced ultrasound (CEUS)
    Hildebrandt, Wulf
    Schwarzbach, Hans
    Pardun, Anita
    Hannemann, Lena
    Bogs, Bjoern
    Koenig, Alexander M.
    Mahnken, Andreas H.
    Hildebrandt, Olaf
    Koehler, Ulrich
    Kinscherf, Ralf
    PLOS ONE, 2017, 12 (03):
  • [30] Perfusion Patterns of Peripheral Pulmonary Metastasis Using Contrast-Enhanced Ultrasound (CEUS) and Their Correlation with Immunohistochemically Detected Vascularization Pattern
    Kroenig, Johannes
    Goerg, Christian
    Prosch, Helmut
    Von Schumann, Lara
    Westhoff, Christina C.
    Alhyari, Amjad
    Koenig, Felix R. M.
    Findeisen, Hajo
    Zadeh, Ehsan Safai
    CANCERS, 2024, 16 (19)