Importance of long-term ground-loop temperature variation in performance optimization of Ground Source Heat Pump system

被引:13
|
作者
Cai, Wanlong [1 ,2 ]
Wang, Fenghao [1 ]
Chen, Shuang [2 ,3 ]
Chen, Chaofan [2 ,3 ]
Zhang, Yuping [4 ]
Kolditz, Olaf [2 ,3 ]
Shao, Haibing [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[2] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[3] Tech Univ Dresden, Fac Environm Sci, Dresden, Germany
[4] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Shallow geothermal energy utilization; Borehole heat exchanger array; Ground-loop temperature; Soil thermal balance; System optimization; GSHP; FEASIBILITY; EFFICIENCY; ENERGY;
D O I
10.1016/j.applthermaleng.2021.117945
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a recent article published in this journal, a series of design optimization was executed for a ground source heat pump system. The optimization was conducted based on a COPall index, which considers both the hydraulic loss on the buried pipe network, as well as the soil thermal balance over a one-year period. In that article, it was concluded that a borehole spacing of 4m is the optimal value. In this short communication, the comprehensive COPall index is re-evaluated with the same system setup with both the TRNSYS and OpenGeoSys-TESPy software, but over a 20-year period. The results show that the borehole heat exchanger array with a spacing of 4m will suffer severe heat accumulation over a 20-year operation. This causes the soil temperature to rise by 5.68 degrees C, along with a decrease of COPall from 4.59 to 4.18. Due to the smaller increase of ground-loop temperature and lower electricity consumption from heat pumps, a larger spacing of 6m will bring better COPall value over the long term, and thus should be recommended. The extended numerical study in this work suggests that when evaluating the performance of a ground source heat pump system, different time duration will lead to different results. Therefore, the variation of long-term ground-loop temperature needs to be quantitatively evaluated in advance, and the system optimization is recommended to be conducted over the entire life cycle of the system.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Case study of the long-term stability and strategy optimization of a ground source heat pump system
    Guo H.
    Wang T.
    Cheng X.
    Guan W.
    Zhao Y.
    Yang J.
    Li J.
    Liu Z.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2024, 64 (05): : 801 - 809
  • [2] Forecast and analysis of long-term operation of ground source heat pump system
    Qi, Zi-Shu
    Gao, Qing
    Yu, Ming
    Liu, Yan
    Bai, Li
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2012, 42 (04): : 877 - 881
  • [3] A Simulink®-Based Building Load-Ground Source Heat Pump Model Used to Assess Short-and Long-Term Heat Pump and Ground Loop Performance
    Gaspredes, Jonathan L.
    Masada, Glenn. Y.
    Moon, Tess. J.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2014, 6 (02)
  • [4] Long-Term Performance Measurement and Analysis of a Small-Scale Ground Source Heat Pump System
    Liu, Hao
    Zhang, Hongyi
    Javed, Saqib
    ENERGIES, 2020, 13 (17)
  • [5] Effect of long-term nanofluid usage on horizontal ground source heat pump performance
    Kapıcıoğlu, Abdullah
    Esen, Hikmet
    Renewable Energy, 2024, 237
  • [6] DEVELOPMENT OF AN INTEGRATED BUILDING LOAD-GROUND SOURCE HEAT PUMP MODEL AS A TEST BED TO ASSESS SHORT- AND LONG-TERM HEAT PUMP AND GROUND LOOP PERFORMANCE
    Gaspredes, Jonathan L.
    Masada, Glenn Y.
    Moon, Tess J.
    PROCEEDINGS OF THE ASME 6TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2012, PTS A AND B, 2012, : 815 - 825
  • [7] Optimization method for multiple heat source operation including ground source heat pump considering dynamic variation in ground temperature
    Ikeda, Shintaro
    Choi, Wonjun
    Ooka, Ryozo
    APPLIED ENERGY, 2017, 193 : 466 - 478
  • [8] Long-Term Monitoring of the Effectiveness of a Ground Source Heat Pump Borehole
    Rubinova, Olga
    Ambrozova, Iva
    Horak, Petr
    ENVIBUILD 2014, 2014, 1041 : 125 - 128
  • [9] Optimization of thermal performance of a building with ground source heat pump system
    Zogou, Olympia
    Stamatelos, Anastassios
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (11) : 2853 - 2863
  • [10] Fast fluid and ground temperature computation for geothermal ground-loop heat exchanger systems
    Marcotte, Denis