Importance of long-term ground-loop temperature variation in performance optimization of Ground Source Heat Pump system

被引:13
|
作者
Cai, Wanlong [1 ,2 ]
Wang, Fenghao [1 ]
Chen, Shuang [2 ,3 ]
Chen, Chaofan [2 ,3 ]
Zhang, Yuping [4 ]
Kolditz, Olaf [2 ,3 ]
Shao, Haibing [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[2] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[3] Tech Univ Dresden, Fac Environm Sci, Dresden, Germany
[4] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Shallow geothermal energy utilization; Borehole heat exchanger array; Ground-loop temperature; Soil thermal balance; System optimization; GSHP; FEASIBILITY; EFFICIENCY; ENERGY;
D O I
10.1016/j.applthermaleng.2021.117945
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a recent article published in this journal, a series of design optimization was executed for a ground source heat pump system. The optimization was conducted based on a COPall index, which considers both the hydraulic loss on the buried pipe network, as well as the soil thermal balance over a one-year period. In that article, it was concluded that a borehole spacing of 4m is the optimal value. In this short communication, the comprehensive COPall index is re-evaluated with the same system setup with both the TRNSYS and OpenGeoSys-TESPy software, but over a 20-year period. The results show that the borehole heat exchanger array with a spacing of 4m will suffer severe heat accumulation over a 20-year operation. This causes the soil temperature to rise by 5.68 degrees C, along with a decrease of COPall from 4.59 to 4.18. Due to the smaller increase of ground-loop temperature and lower electricity consumption from heat pumps, a larger spacing of 6m will bring better COPall value over the long term, and thus should be recommended. The extended numerical study in this work suggests that when evaluating the performance of a ground source heat pump system, different time duration will lead to different results. Therefore, the variation of long-term ground-loop temperature needs to be quantitatively evaluated in advance, and the system optimization is recommended to be conducted over the entire life cycle of the system.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Study on long-term operation characteristics of the medium-deep ground source heat pump system with solar heat storage
    Yuan, Tian
    Yu, Mingzhi
    Mao, Yudong
    Cui, Ping
    Zhang, Wenke
    Zhuang, Zhaoyi
    APPLIED THERMAL ENGINEERING, 2024, 241
  • [32] Integrated operation of PV assisted ground source heat pump and air source heat pump system: Performance analysis and economic optimization
    Zheng, Zhihang
    Zhou, Jin
    Xu, Feng
    Zhang, Rongpeng
    Deng, Guang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 269
  • [33] Experimental study of a closed loop vertical ground source heat pump system
    Hepbasli, A
    Akdemir, O
    Hancioglu, E
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (04) : 527 - 548
  • [34] Long term coupled simulation for ground source heat pump and underground heat exchangers
    Li, Shuhong
    Dong, Kefeng
    Wang, Jinyong
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2015, 106 : 13 - 22
  • [35] Study on the change of soil temperature in Ground Source Heat Pump System
    Han, Shili
    Su, Shunyu
    Liu, Lamei
    Zhou, Chuanhui
    Shi, Lei
    PROCEEDINGS OF THE 2015 INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS, 2015, 40 : 178 - 183
  • [36] The Influence of Dynamic Load on Ground Source Heat Pump System Performance
    Wang, Jingjing
    Zeng, Yunfan
    Tian, Huifang
    Wu, Zhou
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1470 - +
  • [37] Testing and Analysis of Thermal Performance of Ground Source Heat Pump System
    Qu Shilin
    Xu, Ge
    Liu Yimin
    Yu Qian
    2011 2ND INTERNATIONAL CONFERENCE ON CHALLENGES IN ENVIRONMENTAL SCIENCE AND COMPUTER ENGINEERING (CESCE 2011), VOL 11, PT B, 2011, 11 : 566 - 572
  • [38] Heating and cooling performance of a minitype ground source heat pump system
    Zhai, X. Q.
    Cheng, X. W.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 1366 - 1370
  • [39] Alternative refrigerants for the heat pump of a ground source heat pump system
    Sagia, Zoi
    Rakopoulos, Constantinos
    APPLIED THERMAL ENGINEERING, 2016, 100 : 768 - 774
  • [40] Evaluating Long-Term Performance of a Residential Ground-Source Heat Pump System under Climate Change in Cold and Warm Cities of Japan
    Sakata, Yoshitaka
    Akeyama, Yuma
    Katsura, Takao
    Nagano, Katsunori
    ENERGIES, 2023, 16 (06)