Rapid on-site identification of hazardous organic compounds at fire scenes using person-portable gas chromatography-mass spectrometry (GC-MS)-part 2: water sampling and analysis

被引:2
|
作者
Lam, Rylee [1 ]
Lennard, Chris [1 ]
Kingsland, Graham [2 ]
Johnstone, Paul [3 ]
Symons, Andrew [4 ]
Wythes, Laura [5 ]
Fewtrell, Jeremy [6 ]
O'Brien, David [2 ]
Spikmans, Val [1 ]
机构
[1] Western Sydney Univ, Sch Sci & Hlth, Penrith, NSW, Australia
[2] Fire & Rescue NSW, Fire Invest & Res Unit, Greenacre, NSW, Australia
[3] Fire & Rescue NSW, Operat Capabil Directorate, Greenacre, NSW, Australia
[4] Off Environm & Heritage, Environm Protect Sci Branch, Lidcombe, NSW, Australia
[5] New South Wales Environm Protect Author, Hazardous Incidents & Environm Hlth Branch, Sydney, NSW, Australia
[6] Fire & Rescue NSW, Strateg Capabil, Greenacre, NSW, Australia
关键词
Forensic sciences; portable GC-MS; water pollution; field analysis; SPME; fire; VOCs; SVOCs; POLLUTANT EMISSIONS; TG-FTIR; PYROLYSIS; COMBUSTION; WOOD; VOLATILE; FIELD;
D O I
10.1080/20961790.2019.1662648
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Building and factory fires pose a great risk to human and environmental health, due to the release of hazardous by-products of combustion. These hazardous compounds can dissipate into the environment through fire water run-off, and the impact can be immediate or chronic. Current laboratory-based methods do not report hazardous compounds released from a fire scene at the time and location of the event. Reporting of results is often delayed due to the complexities and logistics of laboratory-based sampling and analysis. These delays pose a risk to the health and wellbeing of the environment and exposed community. Recent developments in person-portable instrumentation have the potential to provide rapid analysis of samples in the field. A portable gas chromatograph-mass spectrometer (GC-MS) was evaluated for the on-site analysis of water samples for the identification of hazardous organic compounds at fire scenes. The portable GC-MS was capable of detecting and identifying a range of volatile and semi-volatile organic compounds in fire water run-off, and can be used in conjunction with conventional laboratory analysis methods for a comprehensive understanding of hazardous organics released at fire scenes. Deployment of this portable instrumentation provides first responders with a rapid, on-site screening tool to appropriately manage the run-off water from firefighting activities. This ensures that environmental and human health is proactively protected.
引用
收藏
页码:150 / 164
页数:15
相关论文
共 50 条
  • [21] Biomarker Aroma Compounds of Monofloral Honey From Kazakhstan by Gas Chromatography-Mass Spectrometry (GC-MS) and Chemometric Analysis
    Ongalbek, Damira
    Sahin, Bihter
    Berdesh, Talshyn
    Tas-Kucukaydin, Meltem
    Tokul-Olmez, Ozge
    Yeskaliyeva, Balakyz
    Ozturk, Mehmet
    ANALYTICAL LETTERS, 2024,
  • [22] Gas Chromatography-mass Spectrometry (GC-MS) Analysis of Bioactive Compounds Extracted from Streptomyces antibioticus by Ethyl Acetate
    Sholkamy, Essam N.
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2014, 8 : 761 - 767
  • [23] Determination of Modified QuEChERS Method for Chlorothalonil Analysis in Agricultural Products Using Gas Chromatography-Mass Spectrometry (GC-MS/MS)
    Yun, Da-Young
    Bae, Ji-Yeon
    Park, Chan-Woong
    Jang, Gui-Hyun
    Choe, Won-Jo
    FOODS, 2023, 12 (20)
  • [24] ANALYSIS OF TAMOXIFEN AND ITS METABOLITES BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY (GC-MS) USING MULTIPLE ION DETECTION IN PLASMA
    ADLERCREUTZ, H
    FOTSIS, T
    MARTIN, F
    MURPHY, C
    PANTZAR, P
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 21 (05) : P601 - P602
  • [25] Comparison of measured and recommended acceptance criteria for the analysis of seized drugs using Gas Chromatography-Mass Spectrometry (GC-MS)
    Davidson, J. Tyler
    Lum, Benny J.
    Nano, Gina
    Jackson, Glen P.
    FORENSIC CHEMISTRY, 2018, 10 : 15 - 26
  • [26] Development of gas chromatography-mass spectrometry (GC-MS) and other rapid screening methods for the analysis of 16 'legal high' cathinone derivatives
    Daeid, Niamh Nic
    Savage, Kathleen A.
    Ramsay, Donna
    Holland, Ciara
    Sutcliffe, Oliver B.
    SCIENCE & JUSTICE, 2014, 54 (01) : 22 - 31
  • [27] Gas Chromatography-Mass Spectrometry (GC-MS) Combined with Retention Index Prediction for the Rapid Identification of Halogenated monoterpenes from a Namibian Plocamium species
    Louw, Stefan
    Kandjengo, Lineekela
    Knott, Michael G.
    NATURAL PRODUCT COMMUNICATIONS, 2017, 12 (02) : 207 - 211
  • [28] Analysis of volatile compounds in flesh, peel and seed parts of pumpkin (Cucurbita maxima) cultivated in Ethiopia using gas chromatography-mass spectrometry (GC-MS)
    Hagos, Mulu
    Yaya, Estifanos Ele
    Chandravanshi, Bhagwan Singh
    Redi-Abshiro, Mesfin
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2022, 25 (01) : 1498 - 1512
  • [29] Comparative Phtyochemical Analysis of Kanakasava, Kanakasava Distillate, and Kanakasava Nebulizer Solution using Gas Chromatography-mass Spectrometry (GC-MS)
    Shailesh, Deshpande, V
    Chojer, Rashmi
    Vaishali, Deshpande S.
    ORIENTAL JOURNAL OF CHEMISTRY, 2023, 39 (05) : 1351 - 1359
  • [30] Oil fingerprinting analysis using commercial solid phase extraction (SPE) cartridge and gas chromatography-mass spectrometry (GC-MS)
    Yang, Zeyu
    Yang, Chun
    Wang, Zhendi
    Hollebone, Bruce
    Landriault, Mike
    Brown, Carl E.
    ANALYTICAL METHODS, 2011, 3 (03) : 628 - 635