Bovine jugular vein as right ventricle-to-pulmonary artery valved conduit

被引:1
|
作者
Corno, AF [1 ]
Hurni, M [1 ]
Griffin, H [1 ]
Galal, OM [1 ]
Payot, M [1 ]
Sekarski, N [1 ]
Tozzi, P [1 ]
von Segesser, LK [1 ]
机构
[1] CHU Vaudois, CH-1011 Lausanne, Switzerland
来源
JOURNAL OF HEART VALVE DISEASE | 2002年 / 11卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: The reduced availability of homografts and investigations into the ideal valved conduit have prompted a search for alternative options. This prospective study evaluated the Contegra((R)), a new biological valved conduit consisting of a glutaraldehyde-preserved heterologous bovine jugular vein having a trileaflet venous valve. Methods: Between April 1999 and May 2001, 26 patients (mean age 13.5 +/- 12.5 years; range: 4 months to 43 years), of mean body weight 33.9 +/- 26.7 kg (range: 4.0-91.0 kg), underwent implantation of a Contegra valved conduit for the following diagnoses: pulmonary valve replacement during Ross operation (n = 11), pulmonary atresia with ventricular septal defect (n = 6), tetralogy of Fallot (n = 3), truncus arteriosus (n = 3), Taussig-Bing syndrome (n = 2), and pulmonary valve regurgitation (n = 1). Conduit size was 14 mm in two patients, 16 mm in four, 18 mm in three, 20 mm in three, and 22 mm in 14. Mean cardiopulmonary bypass time was 156 +/- 33 min (range: 105-233 min), and mean aortic cross-clamp time 79 +/- 29 min (range: 0-128 min). Results: There were no hospital deaths. During a mean follow up of 14.7 +/- 6.9 months (range: 1-26 months) there was one late death (4% mortality) that was unrelated to the valved conduit. Three children underwent reoperation; in all cases this was non-conduit-related. All 25 late survivors are currently free from reoperation and complications due to presence of the conduit. Echocardiographically monitored valve regurgitation was absent in 12 cases, trivial in nine and mild in four. The discharge situation was maintained during systematic follow up. No difference was found between the pressure gradient at discharge and at the last follow up. Conclusion: The new conduit provided consistently good results during its first two years of use. The main advantages were: (i) excellent off-the-shelf availability; 60 large variety of available sizes (12 to 22 mm internal diameter); (iii) easy tailoring and suturing; (iv) adequate hemodynamics; (v) no need for proximal or distal extension; and (vi) reduced cost (half that of a conventional homograft).
引用
收藏
页码:242 / 247
页数:6
相关论文
共 50 条
  • [41] Bovine jugular vein valved conduit: Up to 10 years follow-up
    Prior, Natasha
    Alphonso, Nelson
    Arnold, Philip
    Peart, Ian
    Thorburn, Kent
    Venugopal, Prem
    Corno, Antonio F.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04): : 983 - 987
  • [42] Multicenter Experience Evaluating Transcatheter Pulmonary Valve Replacement in Bovine Jugular Vein (Contegra) Right Ventricle to Pulmonary Artery Conduits
    Morray, Brian H.
    McElhinney, Doff B.
    Boudjemline, Younes
    Gewillig, Marc
    Kim, Dennis W.
    Grant, Elena K.
    Bocks, Martin L.
    Martin, Mary H.
    Armstrong, Aimee K.
    Berman, Darren
    Danon, Saar
    Hoyer, Mark
    Delaney, Jeffrey W.
    Justino, Henri
    Qureshi, Athar M.
    Meadows, Jeffery J.
    Jones, Thomas K.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (06)
  • [43] Novel Use of Intravascular Lithotripsy for Percutaneous Relief of Critical Right Ventricle-to-Pulmonary Artery Conduit Stenosis
    Lee, Melissa G. Y.
    Russo, Jeremy J.
    Norman, Samuel
    Binny, Simon D.
    Joshi, Subodh B.
    Eastaugh, Lucas
    Grigg, Leeanne E.
    Wilson, William M.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (21) : 2670 - 2672
  • [44] Cardiovascular Effects of Right Ventricle-Pulmonary Artery Valved Conduit Implantation in Experimental Pulmonic Stenosis
    Saida, Yuuto
    Tanaka, Ryou
    Fukushima, Ryuji
    Hoshi, Katsuichiro
    Hira, Satoshi
    Soda, Aiko
    Iizuka, Tomoya
    Ishikawa, Taisuke
    Nishimura, Taiki
    Yamane, Yoshihisa
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2009, 71 (04): : 477 - 483
  • [45] Early results of valved bovine jugular vein conduit versus bicuspid homograft for right ventricular outflow tract reconstruction
    Bové, T
    Demanet, H
    Wauthy, P
    Goldstein, JP
    Dessy, H
    Viart, P
    Devillé, A
    Deuvaert, FE
    ANNALS OF THORACIC SURGERY, 2002, 74 (02): : 541 - 541
  • [46] FAILURE OF THE HEMASHIELD EXTENSION IN RIGHT VENTRICLE-TO-PULMONARY ARTERY CONDUITS
    KOBAYASHI, J
    BACKER, CL
    ZALES, VR
    CRAWFORD, SE
    MUSTER, AJ
    MAVROUDIS, C
    ANNALS OF THORACIC SURGERY, 1993, 56 (02): : 277 - 281
  • [47] USE OF RIGHT ATRIUM TO PULMONARY-ARTERY VALVED CONDUIT FOR CORRECTION OF SINGLE VENTRICLE OF HYPOPLASTIC RIGHT HEART SYNDROME
    YACOUB, M
    AHMED, M
    RADLEYSMITH, R
    BRITISH HEART JOURNAL, 1975, 37 (07): : 782 - 782
  • [48] Selective Use of the Blalock-Taussig Shunt and Right Ventricle-to-Pulmonary Artery Conduit During the Norwood Procedure
    Murthy, Raghav
    Sebastian, Vinod A.
    Huang, Rong
    Guleserian, Kristine J.
    Forbess, Joseph M.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2016, 7 (03) : 329 - 333
  • [49] True aneurysmal dilatation of a valved bovine jugular vein conduit after right ventricular outflow tract reconstruction: a rare complication
    Yoldas, Tamer
    Orun, Utku A.
    Tak, Sercan
    CARDIOLOGY IN THE YOUNG, 2019, 29 (08) : 1097 - 1098
  • [50] Bovine valved jugular vein (Contegra™) to reconstruct the right ventricular outflow tract
    Carrel, T
    EXPERT REVIEW OF MEDICAL DEVICES, 2004, 1 (01) : 11 - 19