Bovine jugular vein as right ventricle-to-pulmonary artery valved conduit

被引:1
|
作者
Corno, AF [1 ]
Hurni, M [1 ]
Griffin, H [1 ]
Galal, OM [1 ]
Payot, M [1 ]
Sekarski, N [1 ]
Tozzi, P [1 ]
von Segesser, LK [1 ]
机构
[1] CHU Vaudois, CH-1011 Lausanne, Switzerland
来源
JOURNAL OF HEART VALVE DISEASE | 2002年 / 11卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: The reduced availability of homografts and investigations into the ideal valved conduit have prompted a search for alternative options. This prospective study evaluated the Contegra((R)), a new biological valved conduit consisting of a glutaraldehyde-preserved heterologous bovine jugular vein having a trileaflet venous valve. Methods: Between April 1999 and May 2001, 26 patients (mean age 13.5 +/- 12.5 years; range: 4 months to 43 years), of mean body weight 33.9 +/- 26.7 kg (range: 4.0-91.0 kg), underwent implantation of a Contegra valved conduit for the following diagnoses: pulmonary valve replacement during Ross operation (n = 11), pulmonary atresia with ventricular septal defect (n = 6), tetralogy of Fallot (n = 3), truncus arteriosus (n = 3), Taussig-Bing syndrome (n = 2), and pulmonary valve regurgitation (n = 1). Conduit size was 14 mm in two patients, 16 mm in four, 18 mm in three, 20 mm in three, and 22 mm in 14. Mean cardiopulmonary bypass time was 156 +/- 33 min (range: 105-233 min), and mean aortic cross-clamp time 79 +/- 29 min (range: 0-128 min). Results: There were no hospital deaths. During a mean follow up of 14.7 +/- 6.9 months (range: 1-26 months) there was one late death (4% mortality) that was unrelated to the valved conduit. Three children underwent reoperation; in all cases this was non-conduit-related. All 25 late survivors are currently free from reoperation and complications due to presence of the conduit. Echocardiographically monitored valve regurgitation was absent in 12 cases, trivial in nine and mild in four. The discharge situation was maintained during systematic follow up. No difference was found between the pressure gradient at discharge and at the last follow up. Conclusion: The new conduit provided consistently good results during its first two years of use. The main advantages were: (i) excellent off-the-shelf availability; 60 large variety of available sizes (12 to 22 mm internal diameter); (iii) easy tailoring and suturing; (iv) adequate hemodynamics; (v) no need for proximal or distal extension; and (vi) reduced cost (half that of a conventional homograft).
引用
收藏
页码:242 / 247
页数:6
相关论文
共 50 条
  • [21] A Comparison of the Modified Blalock-Taussig Shunt With the Right Ventricle-to-Pulmonary Artery Conduit
    Fiore, Andrew C.
    Tobin, Courtney
    Jureidini, Saadeh
    Rahimi, Mohammad
    Kim, Eric S.
    Schowengerdt, Kenneth
    ANNALS OF THORACIC SURGERY, 2011, 91 (05): : 1479 - 1484
  • [22] Pentagalloyl glucose-stabilized decellularized bovine jugular vein valved conduits as pulmonary conduit replacement
    Sinha, Dipasha
    Nagy-Mehesz, Agnes
    Simionescu, Dan
    Mayer Jr, John E. Mayer
    Vyavahare, Naren
    ACTA BIOMATERIALIA, 2023, 170 : 97 - 110
  • [23] Heterotopically-placed right ventricle-to-pulmonary artery conduit does not negatively affect outcomes
    Khunthorn Kadeetham
    Piya Samankatiwat
    Journal of Cardiothoracic Surgery, 18
  • [24] Interstage management of pulmonary blood flow after the Norwood procedure with right ventricle-to-pulmonary artery conduit
    Yasukawa, Takashi
    Hoashi, Takaya
    Kitano, Masataka
    Shimada, Masatoshi
    Imai, Kenta
    Kurosaki, Kenichi
    Ichikawa, Hajime
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (03) : 551 - 558
  • [25] A Comparison of the Modified Blalock-Taussig Shunt With the Right Ventricle-to-Pulmonary Artery Conduit DISCUSSION
    Tweddell, James S.
    Dr Fiore
    Daicoff, George
    Gandy, Kimberly L.
    ANNALS OF THORACIC SURGERY, 2011, 91 (05): : 1484 - 1485
  • [26] Heterotopically-placed right ventricle-to-pulmonary artery conduit does not negatively affect outcomes
    Kadeetham, Khunthorn
    Samankatiwat, Piya
    JOURNAL OF CARDIOTHORACIC SURGERY, 2023, 18 (01)
  • [27] Right ventricle-to-pulmonary artery conduit versus Blalock-Taussig shunt: A hemodynamic comparison
    Ghanayem, Nancy S.
    Jaquiss, Robert D. B.
    Cava, Joseph R.
    Frommelt, Peter C.
    Mussatto, Kathleen A.
    Hoffman, George M.
    Tweddell, James S.
    ANNALS OF THORACIC SURGERY, 2006, 82 (05): : 1603 - 1610
  • [28] The Modified Blalock–Taussig Shunt Versus the Right Ventricle-to-Pulmonary Artery Conduit for the Norwood Procedure
    Richard G. Ohye
    Eric J. Devaney
    Jennifer C. Hirsch
    Edward L. Bove
    Pediatric Cardiology, 2007, 28 : 122 - 125
  • [29] CLINICAL-RESULTS OF CRYOPRESERVED VALVED CONDUITS IN THE PULMONARY VENTRICLE-TO-PULMONARY ARTERY POSITION
    SHARMA, S
    COBANOGLU, A
    DOBBS, J
    RICE, M
    AMERICAN JOURNAL OF SURGERY, 1993, 165 (05): : 587 - 591
  • [30] USE OF A VALVED CONDUIT FROM RIGHT ATRIUM TO PULMONARY-ARTERY FOR CORRECTION OF SINGLE VENTRICLE
    YACOUB, M
    RADLEYSMITH, R
    CIRCULATION, 1975, 52 (04) : 101 - 101