Prediction of patient-specific quality assurance for volumetric modulated arc therapy using radiomics-based machine learning with dose distribution

被引:0
|
作者
Ishizaka, Natsuki [1 ]
Kinoshita, Tomotaka [2 ]
Sakai, Madoka [3 ,4 ]
Tanabe, Shunpei [4 ]
Nakano, Hisashi [4 ]
Tanabe, Satoshi [4 ]
Nakamura, Sae [5 ]
Mayumi, Kazuki [2 ]
Akamatsu, Shinya [2 ,6 ]
Nishikata, Takayuki [2 ,7 ]
Takizawa, Takeshi [4 ,5 ]
Yamada, Takumi [8 ]
Sakai, Hironori [8 ]
Kaidu, Motoki [9 ]
Sasamoto, Ryuta [2 ]
Ishikawa, Hiroyuki [9 ]
Utsunomiya, Satoru [2 ]
机构
[1] Niigata Prefectural Shibata Hosp, Dept Radiol, Shibata, Niigata, Japan
[2] Niigata Univ, Grad Sch Hlth Sci, Dept Radiol Technol, 2-746 Asahimachi Dori,Chuo Ku, Niigata, Niigata 9518518, Japan
[3] Nagaoka Chuo Gen Hosp, Dept Radiol, Nagaoka, Niigata, Japan
[4] Niigata Univ, Med & Dent Hosp, Dept Radiat Oncol, Niigata, Niigata, Japan
[5] Niigata Neurosurg Hosp, Dept Radiat Oncol, Niigata, Niigata, Japan
[6] Takeda Gen Hosp, Dept Radiol, Aizu Wakamatsu, Fukushima, Japan
[7] Nagaoka Red Cross Hosp, Div Radiol, Nagaoka, Niigata, Japan
[8] Niigata Univ, Med & Dent Hosp, Dept Clin Support, Sect Radiol, Niigata, Niigata, Japan
[9] Niigata Univ, Grad Sch Med & Dent Sci, Dept Radiol & Radiat Oncol, Niigata, Niigata, Japan
来源
基金
日本学术振兴会;
关键词
machine learning; quality assurance; radiomics; volumetric modulated arc therapy; GAMMA PASSING RATE; PLAN COMPLEXITY; ERROR-DETECTION; TOOLS;
D O I
10.1002/acm2.14215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We sought to develop machine learning models to predict the results of patient-specific quality assurance (QA) for volumetric modulated arc therapy (VMAT), which were represented by several dose-evaluation metrics-including the gamma passing rates (GPRs)-and criteria based on the radiomic features of 3D dose distribution in a phantom.Methods A total of 4,250 radiomic features of 3D dose distribution in a cylindrical dummy phantom for 140 arcs from 106 clinical VMAT plans were extracted. We obtained the following dose-evaluation metrics: GPRs with global and local normalization, the dose difference (DD) in 1% and 2% passing rates (DD1% and DD2%) for 10% and 50% dose threshold, and the distance-to-agreement in 1-mm and 2-mm passing rates (DTA1 mm and DTA2 mm) for 0.5%/mm and 1.0%.mm dose gradient threshold determined by measurement using a diode array in patient-specific QA. The machine learning regression models for predicting the values of the dose-evaluation metrics using the radiomic features were developed based on the elastic net (EN) and extra trees (ET) models. The feature selection and tuning of hyperparameters were performed with nested cross-validation in which four-fold cross-validation is used within the inner loop, and the performance of each model was evaluated in terms of the root mean square error (RMSE), the mean absolute error (MAE), and Spearman's rank correlation coefficient.Results The RMSE and MAE for the developed machine learning models ranged from <1% to nearly <10% depending on the dose-evaluation metric, the criteria, and dose and dose gradient thresholds used for both machine learning models. It was advantageous to focus on high dose region for predicating global GPR, DDs, and DTAs. For certain metrics and criteria, it was possible to create models applicable for patients' heterogeneity by training only with dose distributions in phantom.Conclusions The developed machine learning models showed high performance for predicting dose-evaluation metrics especially for high dose region depending on the metric and criteria. Our results demonstrate that the radiomic features of dose distribution can be considered good indicators of the plan complexity and useful in predicting measured dose evaluation metrics.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [32] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786
  • [33] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [34] Evidence based quality assurance of volumetric modulated arc therapy
    Tuemmler, H.
    Bellmann, C.
    Schilling, P.
    Schreiber, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S117 - S117
  • [35] Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification Accuracy
    Li, J.
    Wang, L.
    Zhang, X.
    Liu, L.
    Li, J.
    Chan, M.
    Sui, J.
    Yang, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E497 - E497
  • [36] Prediction of Radiomics-Based Machine Learning for Specific Dosimetric Verification of Pelvic Intensity Modulated Radiotherapy
    Ni, Q.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E479 - E480
  • [37] Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification Accuracy
    Li, Jiaqi
    Wang, Le
    Zhang, Xile
    Liu, Lu
    Li, Jun
    Chan, Maria F.
    Sui, Jing
    Yang, Ruijie
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (04): : 893 - 902
  • [38] Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer
    Zamo, Francis C. Djoumessi
    Njeh, Christopher F.
    Colliaux, Anthony
    Blot-Lafond, Valerie
    Moyo, M. Ndontchueng
    MEDICAL DOSIMETRY, 2024, 49 (03) : 177 - 184
  • [39] Machine Learning Based Prediction for Patient-Specific Quality Assurance: Understand the Plan Complexity for VMAT
    Zhang, X.
    Zhang, Y.
    Liu, B.
    Yue, N.
    Nie, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Development of pretreatment 'truly' patient-specific quality assurance procedure for stereotactic body radiotherapy using volumetric modulated arc radiotherapy
    Tachiiri, S.
    Tanaka, K.
    Tanaka, K.
    Yanagawa, M.
    Kosuga, T.
    Onishi, Y.
    Miyai, A.
    Otsu, S.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S229 - S229