Interference of cardiac implantable electronic devices and computed tomography imaging in the current era with a phantom model

被引:0
|
作者
Ideishi, Akihito [1 ,2 ]
Yamagata, Kenichiro [1 ,5 ]
Nishii, Tatsuya [3 ]
Miyanooi, Hideto [3 ]
Miyazaki, Yuichiro [1 ]
Wakamiya, Akinori [1 ]
Shimamoto, Keiko [1 ]
Ueda, Nobuhiko [1 ]
Nakajima, Kenzaburo [1 ]
Wada, Mitsuru [1 ]
Kamakura, Tsukasa [1 ]
Ishibashi, Kohei [1 ]
Inoue, Yuko [1 ]
Miyamoto, Koji [1 ]
Noda, Takashi [1 ]
Nagase, Satoshi [1 ,4 ]
Aiba, Takeshi [1 ]
Kusano, Kengo [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Med, Suita, Japan
[2] Fukuoka Univ, Sch Med, Dept Cardiol, Fukuoka, Japan
[3] Natl Cerebral & Cardiovasc Ctr, Dept Radiol, Suita, Japan
[4] Natl Cerebral & Cardiovasc Ctr, Dept Adv Arrhythmia & Translat Med Sci, Suita, Japan
[5] Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Med, 6-1 Kishibe Shimmachi, Suita, Osaka 5648565, Japan
关键词
cardiac implantable electronic device; computed tomography; oversensing; IRRADIATION;
D O I
10.1002/joa3.12853
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionCardiac implantable electronic devices are used in patients with cardiac rhythm disorders. Computed tomography irradiation is not prohibited for patients with cardiac implantable electronic devices, despite adverse events being reported. Hence, appropriate preparation and knowledge are required before computed tomography irradiation can be carried out in these patients. Since there is limited knowledge or literature about the influence of computed tomography irradiation in cases with recent cardiac implantable electronic devices, we aimed to evaluate the adverse events and elucidate the necessary and sufficient safety measures associated with this therapy. Methods and ResultsWe placed cardiac implantable electronic devices on an anthropomorphic phantom model and observed their electrical activity in electrograms, while various protocols of computed tomography irradiation were implemented and adverse events evaluated. Oversensing with pauses of up to 3.2 s was observed in standard computed tomography protocols, but ventricular tachyarrhythmia or other clinically significant events could not be confirmed. Oversensing with pauses of up to 8.0 s was observed and ventricular tachyarrhythmia was detected in the maximum-dose protocols. However, treatments such as antitachycardia pacing or shock therapy for ventricular tachyarrhythmia were not observed because of their absence. ConclusionComputed tomography irradiation for patients using cardiac implantable electronic devices is highly unlikely to cause clinically significant adverse events with the device settings and computed tomography protocols currently being used. Changing or monitoring the device settings routinely before computed tomography irradiation is not necessarily required for most patients.
引用
收藏
页码:580 / 585
页数:6
相关论文
共 50 条
  • [41] Electromagnetic Interference and Cardiac Implantable Electronic Devices Is the Ride in Electric Cars Still Cool?
    Turagam, Mohit K.
    Deering, Thomas
    Chung, Mina
    Cheng, Jie
    Fisher, John
    Lakkireddy, Dhanunjaya
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (02) : 210 - 213
  • [42] Magnetic Interference on Cardiac Implantable Electronic Devices From Apple iPhone MagSafe Technology
    Nadeem, Fahd
    Nunez Garcia, Arismendy
    Thach Tran, Cao
    Wu, Michael
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (12):
  • [43] MRI and cardiac implantable electronic devices; current status and required safety conditions
    A. W. M. van der Graaf
    P. Bhagirath
    M. J. W. Götte
    Netherlands Heart Journal, 2014, 22 : 269 - 276
  • [44] Remote programming of cardiac implantable electronic devices: A novel approach to program cardiac devices for magnetic resonance imaging
    Siddamsetti, Sisir
    Shinn, Alexander
    Gautam, Sandeep
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (05) : 1005 - 1009
  • [45] Cardiac MRI for Patients With Cardiac Implantable Electronic Devices
    Stojanovska, Jadranka
    Runge, Mason
    Mahani, Maryam Ghadimi
    Cronin, Paul P.
    Sayyouh, Mohamed
    Bogun, Frank
    Ibrahim, El-Sayed H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 374 - 381
  • [46] MRI and cardiac implantable electronic devices; current status and required safety conditions
    van der Graaf, A. W. M.
    Bhagirath, P.
    Gotte, M. J. W.
    NETHERLANDS HEART JOURNAL, 2014, 22 (06) : 269 - 276
  • [47] Advances in implantable cardiac electronic devices and cardiac electrophysiology
    Denniss, Alan Robert
    Davis, Lloyd M.
    Sanders, Prashanthan
    HEART LUNG AND CIRCULATION, 2012, 21 (6-7): : 309 - 310
  • [48] Australian radiographers' awareness of cardiac implantable electronic devices (CIEDs) in mammographic imaging
    Fitzgerald, J.
    Spuur, K.
    Singh, C.
    Hayre, C.
    Al Mousa, D. S.
    RADIOGRAPHY, 2023, 29 (05) : 984 - 991
  • [49] Imaging for Infected Cardiac Implantable Electronic Devices A New Trick for Your Pet
    Brinker, Jeffrey
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (18) : 1626 - 1628
  • [50] Safety and utility of magnetic resonance imaging in patients with cardiac implantable electronic devices
    Strom, Jordan B.
    Whelan, Jill B.
    Shen, Changyu
    Zheng, Shuang Qi
    Mortele, Koenraad J.
    Kramer, Daniel B.
    HEART RHYTHM, 2017, 14 (08) : 1138 - 1144