Conventional Prostheses versus Sutureless Perceval for Aortic Valve Replacement: A Meta-Analysis

被引:3
|
作者
Colarossi, Giorgia [1 ,2 ]
Migliorini, Filippo [3 ]
Becker, Michael [2 ]
Arias, Jessica P. [1 ]
Autschbach, Ruediger [1 ]
Moza, Ajay [1 ]
Aljalloud, Ali [1 ,2 ]
机构
[1] RWTH Univ Hosp Aachen, Dept Thorac & Cardiovasc Surg, Pauwelsstr 30, D-52074 Aachen, Germany
[2] Rhein Maas Klinikum, Dept Cardiol, Wurselen, Germany
[3] RWTH Univ Hosp Aachen, Dept Orthopaed Trauma & Reconstruct Surg, Aachen, Germany
关键词
Perceval; bioprothesis; sutureless; aortic valve; conventional; BYPASS TIME; INDEPENDENT PREDICTOR; CONDUCTION DISORDERS; MORTALITY; OUTCOMES; SURGERY; BIOPROSTHESIS; TECHNOLOGY; MORBIDITY; DISEASE;
D O I
10.5761/atcs.ra.22-00125
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR).Methods: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were accessed: PubMed, Google Scholar, Web of Science, Scopus, and EMBASE. All clinical investigations comparing Perceval versus the conventional prostheses for AVR were considered.Results: The Perceval group demonstrated higher rate of pacemaker implantation (P <0.00001). Aortic cross-clamp (ACC) time (P <0.00001) and cardiopulmonary bypass (CPB) time (P <0.00001) were shorter in the Perceval group. Similarity was found in mean and peak pressure gradient (P = 0.8 and P = 0.2, respectively), mean aortic valve area (P = 0.3), length of intensive care unit (P = 0.4) and hospital stay (P = 0.2), rate of revision (P = 0.11), hemorrhages (P = 0.05), paravalvular leak (P = 0.3), cerebrovascular complication (P = 0.7), and early mortality (P = 0.06).Conclusion: Given the shorter ACC time and CPB time, Perceval AVR can be an alternative in high-risk patients. The higher rate of pacemaker implantation following Perceval may limit its routine implantation.
引用
收藏
页码:107 / 124
页数:18
相关论文
共 50 条
  • [1] Sutureless Perceval Aortic Valve Versus Conventional Stented Bioprostheses: Meta-Analysis of Postoperative and Midterm Results in Isolated Aortic Valve Replacement
    Meco, Massimo
    Montisci, Andrea
    Miceli, Antonio
    Panisi, Paolo
    Donatelli, Francesco
    Cirri, Silvia
    Ferrarini, Matteo
    Lio, Antonio
    Glauber, Mattia
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (04):
  • [2] Rapid deployment or sutureless versus conventional bioprosthetic aortic valve replacement: A meta-analysis
    Sohn, Suk Ho
    Jang, Myoung-jin
    Hwang, Ho Young
    Kim, Kyung Hwan
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (06): : 2402 - +
  • [3] Outcomes of sutureless aortic valve replacement versus conventional aortic valve replacement and transcatheter aortic valve replacement, updated systematic review, and meta-analysis
    Kim, Kevin S.
    Makhdoum, Ahmad
    Koziarz, Alex
    Gupta, Saurabh
    Alsagheir, Ali
    Pandey, Arjun
    Reza, Seleman
    Um, Kevin
    Teoh, Kevin
    Alhazzani, Waleed
    Lamy, Andre
    Yanagawa, Bobby
    Belley-Cote, Emilie P.
    Whitlock, Richard P.
    [J]. JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4734 - 4742
  • [4] Conventional Biological versus Sutureless Aortic Valve Prostheses in Combined Aortic and Mitral Valve Replacement
    Zubarevich, Alina
    Szczechowicz, Marcin
    Arjomandi Rad, Arian
    Amanov, Lukman
    Ruhparwar, Arjang
    Weymann, Alexander
    [J]. LIFE-BASEL, 2023, 13 (03):
  • [5] Meta-analysis of sutureless technology versus standard aortic valve replacement and transcatheter aortic valve replacement
    Qureshi, Saqib H.
    Boulemden, Anas
    Szafranek, Adam
    Vohra, Hunaid
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (02) : 463 - 471
  • [6] Sutureless Perceval aortic valve implantation compared with conventional Mitroflow valve replacement
    Casha A.R.
    Manché A.
    Camilleri L.
    Yamagata K.
    Santucci S.
    Gauci M.
    Galea J.
    [J]. Indian Journal of Thoracic and Cardiovascular Surgery, 2018, 34 (2) : 109 - 115
  • [7] Sutureless Perceval Aortic Valve Replacement in Aortic Homograft
    Folliguet, Thierry A.
    Laborde, Francois
    [J]. ANNALS OF THORACIC SURGERY, 2013, 96 (05): : 1866 - 1868
  • [8] A Systemic Review and Meta-Analysis of Sutureless Aortic Valve Replacement Versus Transcatheter Aortic Valve Implantation
    Shinn, Sung Ho
    Altarabsheh, Salah E.
    Deo, Salil V.
    Sabik, Joseph H.
    Markowitz, Alan H.
    Park, Soon J.
    [J]. ANNALS OF THORACIC SURGERY, 2018, 106 (03): : 924 - 929
  • [9] Perceval sutureless aortic valve replacement after ascending aortic replacement
    Yajima, Shin
    Satoh, Ayaka
    Sekiya, Naosumi
    Yamazaki, Sachiko
    Uemura, Hisashi
    Tanaka, Hiroe
    Yamamura, Mitsuhiro
    Sakaguchi, Taichi
    [J]. CLINICAL CASE REPORTS, 2021, 9 (12):
  • [10] Transcatheter Aortic Valve Replacement for Perceval Sutureless Aortic Valve Failure
    Kalra, Ankur
    Reyes, Manuel
    Yang, Eric Y.
    Little, Stephen H.
    Nabi, Faisal
    Barker, Colin M.
    Ramchandani, Mahesh
    Reul, Ross M.
    Reardon, Michael J.
    Kleiman, Neal S.
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2017, 29 (06): : E65 - E66