Validation of the Iowa Head-Mounted Open-Source Perimeter

被引:2
|
作者
Heinzman, Zachary [1 ]
Linton, Edward [1 ]
Marin-Franch, Ivan [2 ,3 ]
Turpin, Andrew [4 ]
Alawa, Karam [5 ]
Wijayagunaratne, Anushi [1 ]
Wall, Michael [1 ]
机构
[1] Univ Iowa, Carver Coll Med, Dept Ophthalmol & Visual Sci, Iowa City, IA 52242 USA
[2] Computat Optometry, Atarfe, Spain
[3] Southwest Eye Inst, Tavistock, England
[4] Curtin Univ, Curtin Sch Populat Hlth, Bentley, WA, Australia
[5] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, Boston, MA 02115 USA
来源
关键词
virtual reality; glaucoma; perimetry; visual field; STANDARD AUTOMATED PERIMETRY; VISUAL-FIELD PROGRESSION; EFFECTIVE DYNAMIC RANGES; STIMULUS SIZES III; MATRIX; MOTION;
D O I
10.1167/tvst.12.9.19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the validity of visual field (VF) results from the Iowa Head-Mounted Display (HMD) Open-Source Perimeter and to test the hypothesis that VF defects and test-retest repeatability are similar between the HMD and Octopus 900 perimeters. Methods: We tested 20 healthy and nine glaucoma patients on the HMD and Octopus 900 perimeters using the Open Perimetry Interface platform with size V stimuli, a custom grid spanning the central 26 degrees of the VF, and a ZEST thresholding algorithm. Historical data from the Humphrey Field Analyzer (HFA) were also analyzed. Repeatability was analyzed with the repeatability coefficient (RC), and VF defect detection was determined through side-by-side comparisons. Results: The pointwise RCs were 2.6 dB and 3.4 dB for the HMD and Octopus 900 perimeters in ocular healthy subjects, respectively. Likewise, the RCs were 4.2 dB and 3.5 dB, respectively, in glaucomatous patients. Limits of agreement between the HMD and Octopus 900 perimeters were +/- 4.6 dB (mean difference, 0.4 dB) for healthy patients and +/- 8.9 dB (mean difference, 0.1 dB) for glaucomatous patients. Retrospective analysis showed that pointwise RCs on the HFA2 perimeter were between 3.4 and 3.7 dB for healthy patients and between 3.9 and 4.7 dB for glaucoma patients. VF defects were similar between the HMD and Octopus 900 for glaucoma subjects. Conclusions: The Iowa Virtual Reality HMD Open-Source Perimeter is as repeatable as the Octopus 900 perimeter and is a more portable and less expensive alternative than traditional perimeters. Translational Relevance: This study demonstrates the validity of the visual field results from the Iowa HMD Open-Source Perimeter which may help expand perimetry access.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Head-mounted perimeter.
    Eizenman, M
    Chan, ADC
    Flanagan, JG
    Trope, GE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S85 - S85
  • [2] Validation of a Novel Head-Mounted Perimeter versus the Humphrey Field Analyzer
    Najdawi, Wisam
    Johnson, Chris
    Pouw, Andrew
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [3] CAVE: An Open-Source Tool for Combined Analysis of Head-Mounted Calcium Imaging and Behavior in MATLAB
    Tegtmeier, Jennifer
    Brosch, Marcel
    Janitzky, Kathrin
    Heinze, Hans-Jochen
    Ohl, Frank W.
    Lippert, Michael T.
    [J]. FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [4] EyeRecToo: Open-source Software for Real-time Pervasive Head-mounted Eye Tracking
    Santini, Thiago
    Fuhl, Wolfgang
    Geisler, David
    Kasneci, Enkelejda
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS (VISIGRAPP 2017), VOL 6, 2017, : 96 - 101
  • [5] Visual Field Testing with Head-Mounted Perimeter 'imo'
    Matsumoto, Chota
    Yamao, Sayaka
    Nomoto, Hiroki
    Takada, Sonoko
    Okuyama, Sachiko
    Kimura, Shinji
    Yamanaka, Kenzo
    Aihara, Makoto
    Shimomura, Yoshikazu
    [J]. PLOS ONE, 2016, 11 (08):
  • [6] Measurement of Fixational Eye MovementsWith the Head-Mounted Perimeter Imo
    Ishibashi, Takuya
    Matsumoto, Chota
    Nomoto, Hiroki
    Tanabe, Fumi
    Narita, Ikumi
    Ishibashi, Marika
    Okuyama, Sachiko
    Kayazawa, Tomoyasu
    Kimura, Shinji
    Yamanaka, Kenzo
    Kusaka, Shunji
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (08):
  • [7] Measurements of fixation eye movements with head-mounted perimeter "imo"
    Ishibashi, Takuya
    Matsumoto, Chota
    Nomoto, Hiroki
    Umebara, Ikumi
    Wakayama, Akemi
    Kimura, Shinji
    Shimomura, Yoshikazu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Comparison of head-mounted perimeter (imo®) and Humphrey Field Analyzer
    Kimura, Tairo
    Matsumoto, Chota
    Nomoto, Hiroki
    [J]. CLINICAL OPHTHALMOLOGY, 2019, 13 : 501 - 513
  • [9] Effects of head tilt on visual field testing with a head-mounted perimeter imo
    Yamao, Sayaka
    Matsumoto, Chota
    Nomoto, Hiroki
    Numata, Takuya
    Eura, Mariko
    Yamashita, Marika
    Hashimoto, Shigeki
    Okuyama, Sachiko
    Kimura, Shinji
    Yamanaka, Kenzo
    Chiba, Yasutaka
    Aihara, Makoto
    Shimomura, Yoshikazu
    [J]. PLOS ONE, 2017, 12 (09):
  • [10] Measurements of fixational eye movements using the head-mounted perimeter "imo"
    Ishibashi, Takuya
    Matsumoto, Chota
    Nomoto, Hiroki
    Tanabe, Fumi
    Kimura, Shinji
    Kusaka, Shunji
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)