Visual Field Testing with Head-Mounted Perimeter 'imo'

被引:54
|
作者
Matsumoto, Chota [1 ]
Yamao, Sayaka [1 ]
Nomoto, Hiroki [1 ]
Takada, Sonoko [1 ]
Okuyama, Sachiko [1 ]
Kimura, Shinji [2 ]
Yamanaka, Kenzo [2 ]
Aihara, Makoto [3 ,4 ]
Shimomura, Yoshikazu [1 ]
机构
[1] Kindai Univ, Fac Med Osaka Sayama City, Dept Ophthalmol, Osaka, Japan
[2] CREWT Med Syst Inc, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[4] Univ Tokyo, Fac Med, Tokyo, Japan
来源
PLOS ONE | 2016年 / 11卷 / 08期
关键词
FREQUENCY-DOUBLING TECHNOLOGY; ADAPTATION;
D O I
10.1371/journal.pone.0161974
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose We developed a new portable head-mounted perimeter, "imo", which performs visual field (VF) testing under flexible conditions without a dark room. Besides the monocular eye test, imo can present a test target randomly to either eye without occlusion (a binocular random single eye test). The performance of imo was evaluated. Methods Using full HD transmissive LCD and high intensity LED backlights, imo can display a test target under the same test conditions as the Humphrey Field Analyzer (HFA). The monocular and binocular random single eye tests by imo and the HFA test were performed on 40 eyes of 20 subjects with glaucoma. VF sensitivity results by the monocular and binocular random single eye tests were compared, and these test results were further compared to those by the HFA. The subjects were asked whether they noticed which eye was being tested during the test. Results The mean sensitivity (MS) obtained with the HFA highly correlated with the MS by the imo monocular test (R: r = 0.96, L: r = 0.94, P < 0.001) and the binocular random single eye test (R: r = 0.97, L: r = 0.98, P < 0.001). The MS values by the monocular and binocular random single eye tests also highly correlated (R: r = 0.96, L: r = 0.95, P < 0.001). No subject could detect which eye was being tested during the examination. Conclusions The perimeter imo can obtain VF sensitivity highly compatible to that by the standard automated perimeter. The binocular random single eye test provides a non-occlusion test condition without the examinee being aware of the tested eye.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effects of head tilt on visual field testing with a head-mounted perimeter imo
    Yamao, Sayaka
    Matsumoto, Chota
    Nomoto, Hiroki
    Numata, Takuya
    Eura, Mariko
    Yamashita, Marika
    Hashimoto, Shigeki
    Okuyama, Sachiko
    Kimura, Shinji
    Yamanaka, Kenzo
    Chiba, Yasutaka
    Aihara, Makoto
    Shimomura, Yoshikazu
    [J]. PLOS ONE, 2017, 12 (09):
  • [2] Comparison of head-mounted perimeter (imo®) and Humphrey Field Analyzer
    Kimura, Tairo
    Matsumoto, Chota
    Nomoto, Hiroki
    [J]. CLINICAL OPHTHALMOLOGY, 2019, 13 : 501 - 513
  • [3] Measurement of Fixational Eye MovementsWith the Head-Mounted Perimeter Imo
    Ishibashi, Takuya
    Matsumoto, Chota
    Nomoto, Hiroki
    Tanabe, Fumi
    Narita, Ikumi
    Ishibashi, Marika
    Okuyama, Sachiko
    Kayazawa, Tomoyasu
    Kimura, Shinji
    Yamanaka, Kenzo
    Kusaka, Shunji
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (08):
  • [4] Measurements of fixation eye movements with head-mounted perimeter "imo"
    Ishibashi, Takuya
    Matsumoto, Chota
    Nomoto, Hiroki
    Umebara, Ikumi
    Wakayama, Akemi
    Kimura, Shinji
    Shimomura, Yoshikazu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [5] A Novel Visual Field Screening Program for Glaucoma With a Head-Mounted Perimeter
    Arai, Kota
    Nishijima, Euido
    Ogawa, Shumpei
    Hosaka, Daisuke
    Itoh, Yoshinori
    Noro, Takahiko
    Okude, Sachiyo
    Okada, Satomi
    Yoshikawa, Keiji
    Nakano, Tadashi
    [J]. JOURNAL OF GLAUCOMA, 2023, 32 (06) : 520 - 525
  • [6] Measurements of fixational eye movements using the head-mounted perimeter "imo"
    Ishibashi, Takuya
    Matsumoto, Chota
    Nomoto, Hiroki
    Tanabe, Fumi
    Kimura, Shinji
    Kusaka, Shunji
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [7] A head mounted perimeter "imo": visual field test results in normal subjects.
    Nomoto, Hiroki
    Matsumoto, Chota
    Okuyama, Sachiko
    Minamino, Asami
    Kimura, Tairou
    Yoshikawa, Keiji
    Mizoue, Shiro
    Iwase, Aiko
    Aihara, Makoto
    Numata, Takuya
    Yamao, Sayaka
    Kimura, Shinji
    Shimomura, Yoshikazu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Head-mounted perimeter.
    Eizenman, M
    Chan, ADC
    Flanagan, JG
    Trope, GE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S85 - S85
  • [9] Comparing a head-mounted virtual reality perimeter and the Humphrey Field Analyzer for visual field testing in healthy and glaucoma patients
    Phu, Jack
    Wang, Henrietta
    Kalloniatis, Michael
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024, 44 (01) : 83 - 95
  • [10] Comparison of monocular sensitivities measured with and without occlusion using the head-mounted perimeter imo
    Wakayama, Akemi
    Matsumoto, Chota
    Ayato, Yoriko
    Shimomura, Yoshikazu
    [J]. PLOS ONE, 2019, 14 (01):