Visual Field Testing with Head-Mounted Perimeter 'imo'

被引:54
|
作者
Matsumoto, Chota [1 ]
Yamao, Sayaka [1 ]
Nomoto, Hiroki [1 ]
Takada, Sonoko [1 ]
Okuyama, Sachiko [1 ]
Kimura, Shinji [2 ]
Yamanaka, Kenzo [2 ]
Aihara, Makoto [3 ,4 ]
Shimomura, Yoshikazu [1 ]
机构
[1] Kindai Univ, Fac Med Osaka Sayama City, Dept Ophthalmol, Osaka, Japan
[2] CREWT Med Syst Inc, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[4] Univ Tokyo, Fac Med, Tokyo, Japan
来源
PLOS ONE | 2016年 / 11卷 / 08期
关键词
FREQUENCY-DOUBLING TECHNOLOGY; ADAPTATION;
D O I
10.1371/journal.pone.0161974
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose We developed a new portable head-mounted perimeter, "imo", which performs visual field (VF) testing under flexible conditions without a dark room. Besides the monocular eye test, imo can present a test target randomly to either eye without occlusion (a binocular random single eye test). The performance of imo was evaluated. Methods Using full HD transmissive LCD and high intensity LED backlights, imo can display a test target under the same test conditions as the Humphrey Field Analyzer (HFA). The monocular and binocular random single eye tests by imo and the HFA test were performed on 40 eyes of 20 subjects with glaucoma. VF sensitivity results by the monocular and binocular random single eye tests were compared, and these test results were further compared to those by the HFA. The subjects were asked whether they noticed which eye was being tested during the test. Results The mean sensitivity (MS) obtained with the HFA highly correlated with the MS by the imo monocular test (R: r = 0.96, L: r = 0.94, P < 0.001) and the binocular random single eye test (R: r = 0.97, L: r = 0.98, P < 0.001). The MS values by the monocular and binocular random single eye tests also highly correlated (R: r = 0.96, L: r = 0.95, P < 0.001). No subject could detect which eye was being tested during the examination. Conclusions The perimeter imo can obtain VF sensitivity highly compatible to that by the standard automated perimeter. The binocular random single eye test provides a non-occlusion test condition without the examinee being aware of the tested eye.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Perception of the vertical with a head-mounted visual frame during head tilt
    Mars, F
    Vercher, JL
    Blouin, J
    [J]. ERGONOMICS, 2004, 47 (10) : 1116 - 1130
  • [42] The head-mounted microscope
    Chen, Ting
    Dailey, Seth H.
    Naze, Sawyer A.
    Jiang, Jack J.
    [J]. LARYNGOSCOPE, 2012, 122 (04): : 781 - 784
  • [43] Head-mounted displays
    Tomilin, MG
    [J]. JOURNAL OF OPTICAL TECHNOLOGY, 1999, 66 (06) : 528 - 533
  • [44] Low-cost, smartphone-based frequency doubling technology visual field testing using a head-mounted display
    Alawa, Karam AlRahman
    Nolan, Ryan P.
    Han, Elaine
    Arboleda, Alejandro
    Durkee, Heather
    Sayed, Mohamed S.
    Aguilar, Mariela C.
    Lee, Richard K.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (03) : 440 - 444
  • [45] Head-mounted displays
    King, D
    [J]. COMPUTER GRAPHICS WORLD, 1995, 18 (08) : 101 - 102
  • [46] EXTREME FIELD-OF-VIEW FOR HEAD-MOUNTED DISPLAYS
    Rakkolainen, Ismo
    Raisamo, Roope
    Turk, Matthew
    Hollerer, Tobias
    Palovuori, Karri
    [J]. 2017 3DTV CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO (3DTV-CON), 2017,
  • [47] Wide field of view catadioptrical head-mounted display
    Nagahara, H
    Yagi, Y
    Yachida, M
    [J]. IROS 2003: PROCEEDINGS OF THE 2003 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, 2003, : 3738 - 3743
  • [48] Evaluation of Pupil Fields Using a Newly Developed Head-mounted Perimeter in Healthy Subjects
    Asakawa, Ken
    Nanno, Mami
    Ishikawa, Hitoshi
    Shoji, Nobuyuki
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (09) : 807 - 815
  • [49] The Effect of a Head-mounted Low Vision Device on Visual Function
    Wittich, Walter
    Lorenzini, Marie-Celine
    Markowitz, Samuel N.
    Tolentino, Michael
    Gartner, Scott A.
    Goldstein, Judith E.
    Dagnelie, Gislin
    [J]. OPTOMETRY AND VISION SCIENCE, 2018, 95 (09) : 774 - 784
  • [50] STMA: A Fast Visual Field Defect Assessment Method Using Quadtree and Head-Mounted Display
    Ge, Chao
    Zhu, Zhenyang
    Kashiwagi, Kenji
    Toyoura, Masahiro
    Go, Kentaro
    Fujishiro, Issei
    Mao, Xiaoyang
    [J]. 2024 NICOGRAPH INTERNATIONAL, NICOINT 2024, 2024, : 1 - 8