Measurements of fetal dose with Mevion S250i proton therapy system with HYPERSCAN

被引:3
|
作者
Hopfensperger, Karolyn M. [1 ,3 ]
Li, Xing [2 ]
Paxton, Adam [2 ]
Sarkar, Vikren [2 ]
Su, Fan-Chi Frances [2 ]
Price, Ryan G. [2 ]
Salter, Bill [2 ]
St. James, Sara [2 ]
机构
[1] Univ Kansas Med Ctr, Dept Radiat Oncol, Kansas City, KS USA
[2] Univ Utah, Huntsman Canc Inst, Dept Radiat Oncol, Salt Lake City, UT USA
[3] Univ KansasMed Ctr, Dept Radiat Oncol, 4001 Rainbow Blvd, RmRO1126, Kansas City, KS 66160 USA
来源
关键词
fetal dose; scanning beam proton therapy; NEUTRON; RADIOTHERAPY; PATIENT;
D O I
10.1002/acm2.13957
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize potential dose to the fetus for all modes of delivery (dynamic adaptive aperture, static adaptive aperture, and no adaptive aperture) for the Mevion S250i Proton Therapy System with HYPERSCAN and compare the findings with those of other available proton systems. Materials and Methods: Fetal dose measurements were performed for all three modes of dose delivery on the Mevion S250i Proton therapy system with HYPERSCAN (static aperture, dynamic aperture and uncollimated). Standard treatment plans were created in RayStation for a left-sided brain lesion treated with a vertex field, a left lateral field, and a posterior field. Measurements were performed using WENDI and the RANDO with the detector placed at representative locations to mimic the growth and movement of the fetus at different gestational stages. Results: The fetal dose measurements varied with fetus position and the largest measured dose was 64.7 mu Sv per 2 Gy (RBE) fraction using the dynamic aperture. The smallest estimated fetal dose was 45.0 mu Sv per 2 Gy (RBE) at the base of the RANDO abdomen (47 cm from isocenter to the outer width of WENDI and 58.5 cm from the center of the WENDI detector) for the static aperture delivery. The vertex fields at all depths had larger contributions to the total dose than the other two and the dynamic aperture plans resulted in the highest dose measured for all depths. Conclusion: The reported doses are lower than reported doses using a double-scattering system. This work suggests that avoiding vertex fields and using the static aperture will help minimize dose to the fetus.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Neutron spectrum measurements from 250-MeV passively scattered proton therapy
    Howell, R. M.
    Burgett, E. A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S103 - S104
  • [42] A Monte Carlo-Based Analytic Model of Neutron Dose Equivalent for a Mevion Gantry-Mounted Passively Scattered Proton System
    BaradaranGhahfarokhi, M.
    Reynoso, F.
    Sun, B.
    Darafsheh, A.
    Prusator, M.
    Mutic, S.
    Zhao, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E682 - E682
  • [43] Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation
    Howell, Rebecca M.
    Burgett, Eric A.
    Isaacs, Daniel
    Hedrick, Samantha G. Price
    Reilly, Michael P.
    Rankine, Leith J.
    Grantham, Kevin K.
    Perkins, Stephanie
    Klein, Eric E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 249 - 257
  • [44] Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations
    Lin, Yung-Chieh
    Lee, Chung-Chi
    Chao, Tsi-Chian
    Tsai, Hui-Yu
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 290 - 294
  • [45] Prompt gamma measurements for locating the dose falloff region in the proton therapy
    Min, Chul-Hee
    Kim, Chan Hyeong
    Youn, Min-Young
    Kim, Jong-Won
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (18)
  • [46] Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams
    Zheng, Yuanshui
    Liu, Yaxi
    Zeidan, Omar
    Schreuder, Andries Niek
    Keole, Sameer
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3484 - 3492
  • [47] 迈胜S250i型质子治疗系统的束流性能及机械精度验收测试
    吴韦清
    卢晓光
    郑仁超
    刘飞
    胡广原
    袁响林
    [J]. 中国医学装备, 2024, 21 (09) : 13 - 17
  • [48] A simple proton-radiography system for accurate RSP measurements in proton therapy
    Olivari, F.
    van der Graaf, E.
    van Goethem, M.
    Brandenburg, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1372 - S1373
  • [49] Independent Dose Verification System for Spot Scanning Proton Therapy
    Li, Y.
    Lii, M.
    Li, H.
    Taylor, M.
    Li, X.
    Zhu, X.
    Sahoo, N.
    Gillin, M.
    Zhang, X.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3714 - 3714
  • [50] A Monte Carlo-based analytic model of neutron dose equivalent for a mevion gantry-mounted passively scattered proton system for craniospinal irradiation
    Baradaran-Ghahfarokhi, Milad
    Reynoso, Francisco
    Sun, Baozhou
    Darafsheh, Arash
    Prusator, Michael T.
    Mutic, Sasa
    Zhao, Tianyu
    [J]. MEDICAL PHYSICS, 2020, 47 (09) : 4509 - 4521