Towards a hygroscopic growth calibration for low-cost PM2.5 sensors

被引:0
|
作者
Patel, Milan Y. [1 ]
Vannucci, Pietro F. [1 ]
Kim, Jinsol [2 ]
Berelson, William M. [2 ]
Cohen, Ronald C. [1 ,3 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Univ Southern Calif, Dept Earth Sci, Los Angeles, CA 90089 USA
[3] Univ Calif Berkeley, Dept Earth & Planetary Sci, Berkeley, CA 94720 USA
关键词
AEROSOL; AMBIENT; TRENDS; LINK; PART;
D O I
10.5194/amt-17-1051-2024
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Low-cost particulate matter (PM) sensors continue to grow in popularity, but issues such as aerosol-size-dependent sensitivity drive the need for effective calibration schemes. Here we devise a time-evolving calibration method for the Plantower PMS5003 PM2.5 mass concentration measurements. We use 2 years of measurements from the Berkeley Environmental Air-quality and CO2 Network sensors deployed in San Francisco and Los Angeles in our analysis. The calibration uses a hygroscopic growth correction factor derived from kappa-K & ouml;hler theory, where the calibration parameters are determined empirically using US Environmental Protection Agency Air Quality System (EPA AQS) reference data at co-location sites during the period from 2021-2022. The parameters are found to vary cyclically through the seasons, and the seasonal cycles match changes in sulfate and elemental carbon PM composition fractions throughout the year. In both regions, the seasonal RH dependence calibration performs better than the uncalibrated data and data calibrated with the EPA's national Plantower calibration algorithm. In the San Francisco Bay Area, the seasonal RH dependence calibration reduces the root mean square error (RMSE) by similar to 40 % from the uncalibrated data and maintains a mean bias much smaller than the EPA national calibration scheme (-0.90 vs -2.73 mu g m(-3)). We also find that calibration parameters forecasted beyond those fit with the EPA reference data continue to outperform the uncalibrated data and EPA calibration data, enabling real-time application of the calibration scheme even in the absence of reference data. While the correction greatly improves the data accuracy, non-Gaussian distribution of the residuals suggests that other processes besides hygroscopic growth can be parameterized for future improvement of this calibration.
引用
下载
收藏
页码:1051 / 1060
页数:10
相关论文
共 50 条
  • [41] An efficient spatiotemporal data calibration approach for the low-cost PM2.5 sensing network: A case study in Taiwan
    Lee, Chieh-Han
    Wang, Yeuh-Bin
    Yu, Hwa-Lung
    ENVIRONMENT INTERNATIONAL, 2019, 130
  • [42] Calibration of DustTrak and Low-Cost Sensors and Their Application for Assessment of Inhalation Exposures to Traffic-Related PM2.5 and PM1 in Ho Chi Minh City
    Chi, Nguyen Doan Thien
    Ngan, Tran Anh
    Cong-Thanh, Tran
    Huy, Duong Huu
    Lung, Shih-Chun Candice
    Hien, To Thi
    ATMOSPHERE, 2023, 14 (10)
  • [43] A distributed network of low-cost continuous reading sensors to measure spatiotemporal variations of PM2.5 in Xi'an, China
    Gao, Meiling
    Cao, Junji
    Seto, Edmund
    ENVIRONMENTAL POLLUTION, 2015, 199 : 56 - 65
  • [44] Environmental justice analysis of wildfire-related PM2.5 exposure using low-cost sensors in California
    Kramer, Amber L.
    Liu, Jonathan
    Li, Liqiao
    Connolly, Rachel
    Barbato, Michele
    Zhu, Yifang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 856
  • [45] Measuring Spatial and Temporal PM2.5 Variations in Sacramento, California, Communities Using a Network of Low-Cost Sensors
    Mukherjee, Anondo
    Brown, Steven G.
    McCarthy, Michael C.
    Pavlovic, Nathan R.
    Stanton, Levi G.
    Snyder, Janice Lam
    D'Andrea, Stephen
    Hafner, Hilary R.
    SENSORS, 2019, 19 (21)
  • [46] Development of a PM2.5 Forecasting System Integrating Low-cost Sensors for Ho Chi Minh City, Vietnam
    Nguyen Ky Phung
    Nguyen Quang Long
    Nguyen Van Tin
    Dang Thi Thanh Le
    AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (06) : 1454 - 1468
  • [47] Calibrating low-cost sensors using MERRA-2 reconstructed PM2.5 mass concentration as a proxy
    Malyan, Vasudev
    Kumar, Vikas
    Sahu, Manoranjan
    Prakash, Jai
    Choudhary, Shruti
    Raliya, Ramesh
    Chadha, Tandeep S.
    Fang, Jiaxi
    Biswas, Pratim
    ATMOSPHERIC POLLUTION RESEARCH, 2024, 15 (03)
  • [48] Evaluations of Low-cost Air Quality Sensors for Particulate Matter (PM2.5) under Indoor and Outdoor Conditions
    Rabuan, Utbah
    Nadzir, Mohd Shahrul Mohd
    Sham, Siti Zahanah Abdullah
    Bahri, Sharifah Batrisyia Izzati Wan Shaiful
    Borah, Jintu
    Majumdar, Shubhankar
    Lei, Thomas M. T.
    Ali, Sawal Hamid Md
    Wahab, Muhammad Ikram A.
    Yunus, Noor Hidayah Mohd
    SENSORS AND MATERIALS, 2023, 35 (08) : 2881 - 2895
  • [49] Traffic exhaust to wildfires: PM2.5 measurements with fixed and portable, low-cost LoRaWAN-connected sensors
    Forehead, Hugh
    Barthelemy, Johan
    Arshad, Bilal
    Verstaevel, Nicolas
    Price, Owen
    Perez, Pascal
    PLOS ONE, 2020, 15 (04):