Towards a hygroscopic growth calibration for low-cost PM2.5 sensors

被引:0
|
作者
Patel, Milan Y. [1 ]
Vannucci, Pietro F. [1 ]
Kim, Jinsol [2 ]
Berelson, William M. [2 ]
Cohen, Ronald C. [1 ,3 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Univ Southern Calif, Dept Earth Sci, Los Angeles, CA 90089 USA
[3] Univ Calif Berkeley, Dept Earth & Planetary Sci, Berkeley, CA 94720 USA
关键词
AEROSOL; AMBIENT; TRENDS; LINK; PART;
D O I
10.5194/amt-17-1051-2024
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Low-cost particulate matter (PM) sensors continue to grow in popularity, but issues such as aerosol-size-dependent sensitivity drive the need for effective calibration schemes. Here we devise a time-evolving calibration method for the Plantower PMS5003 PM2.5 mass concentration measurements. We use 2 years of measurements from the Berkeley Environmental Air-quality and CO2 Network sensors deployed in San Francisco and Los Angeles in our analysis. The calibration uses a hygroscopic growth correction factor derived from kappa-K & ouml;hler theory, where the calibration parameters are determined empirically using US Environmental Protection Agency Air Quality System (EPA AQS) reference data at co-location sites during the period from 2021-2022. The parameters are found to vary cyclically through the seasons, and the seasonal cycles match changes in sulfate and elemental carbon PM composition fractions throughout the year. In both regions, the seasonal RH dependence calibration performs better than the uncalibrated data and data calibrated with the EPA's national Plantower calibration algorithm. In the San Francisco Bay Area, the seasonal RH dependence calibration reduces the root mean square error (RMSE) by similar to 40 % from the uncalibrated data and maintains a mean bias much smaller than the EPA national calibration scheme (-0.90 vs -2.73 mu g m(-3)). We also find that calibration parameters forecasted beyond those fit with the EPA reference data continue to outperform the uncalibrated data and EPA calibration data, enabling real-time application of the calibration scheme even in the absence of reference data. While the correction greatly improves the data accuracy, non-Gaussian distribution of the residuals suggests that other processes besides hygroscopic growth can be parameterized for future improvement of this calibration.
引用
下载
收藏
页码:1051 / 1060
页数:10
相关论文
共 50 条
  • [1] Concentration-Temporal Multilevel Calibration of Low-Cost PM2.5 Sensors
    Day, Rong-Fuh
    Yin, Peng-Yeng
    Huang, Yuh-Chin T.
    Wang, Cheng-Yi
    Tsai, Chih-Chun
    Yu, Cheng-Hsien
    SUSTAINABILITY, 2022, 14 (16)
  • [2] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Chu, Hone-Jay
    Ali, Muhammad Zeeshan
    He, Yu-Chen
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Hone-Jay Chu
    Muhammad Zeeshan Ali
    Yu-Chen He
    Scientific Reports, 10
  • [4] LOW-PROCESSING DATA ENRICHMENT AND CALIBRATION FOR PM2.5 LOW-COST SENSORS
    Stojanovi, Danka B.
    Kleut, Duska N.
    Davidovi, Milos D.
    De Vito, Saverio
    Jovasevi-Stojanovi, Milena, V
    Bartonova, Alena
    Lepioufle, Jean-Marie
    THERMAL SCIENCE, 2023, 27 (3B): : 2229 - 2240
  • [5] A System Calibration Model for Mobile PM2.5 Sensing Using Low-Cost Sensors
    Liu, Hao-Min
    Wu, Hsuan-Cho
    Lee, Hu-Chen
    Ho, Yao-Hua
    Chen, Ling-Jyh
    2017 IEEE INTERNATIONAL CONFERENCE ON INTERNET OF THINGS (ITHINGS) AND IEEE GREEN COMPUTING AND COMMUNICATIONS (GREENCOM) AND IEEE CYBER, PHYSICAL AND SOCIAL COMPUTING (CPSCOM) AND IEEE SMART DATA (SMARTDATA), 2017, : 611 - 618
  • [6] Domain Adaptation-Based Deep Calibration of Low-Cost PM2.5 Sensors
    Jha, Sonu Kumar
    Kumar, Mohit
    Arora, Vipul
    Tripathi, Sachchida Nand
    Motghare, Vidyanand Motiram
    Shingare, A. A.
    Rajput, Karansingh A.
    Kamble, Sneha
    IEEE SENSORS JOURNAL, 2021, 21 (22) : 25941 - 25949
  • [7] Evaluation of Low-Cost Sensors for Ambient PM2.5 Monitoring
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    JOURNAL OF SENSORS, 2018, 2018
  • [8] Ensemble learning of model hyperparameters and spatiotemporal data for calibration of low-cost PM2.5 sensors
    Yin, Peng-Yeng
    Tsai, Chih-Chun
    Day, Rong-Fuh
    Tung, Ching-Ying
    Bhanu, Bir
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2019, 16 (06) : 6858 - 6873
  • [9] Low-cost PM2.5 Sensors: An Assessment of their Suitability for Various Applications
    Jayaratne, Rohan
    Liu, Xiaoting
    Ahn, Kang-Ho
    Asumadu-Sakyi, Akwasi
    Fisher, Gavin
    Gao, Jian
    Mabon, Adrian
    Mazaheri, Mandana
    Mullins, Benjamin
    Nyaku, Mawutorli
    Ristovski, Zoran
    Scorgie, Yvonne
    Phong Thai
    Dunbabin, Matthew
    Morawska, Lidia
    AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (03) : 520 - 532
  • [10] Evaluating the Performance of Low-Cost PM2.5 Sensors in Mobile Settings
    deSouza, Priyanka
    Wang, An
    Machida, Yuki
    Duhl, Tiffany
    Mora, Simone
    Kumar, Prashant
    Kahn, Ralph
    Ratti, Carlo
    Durant, John L.
    Hudda, Neelakshi
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (41) : 15401 - 15411