Low-cost PM2.5 Sensors: An Assessment of their Suitability for Various Applications

被引:55
|
作者
Jayaratne, Rohan [1 ]
Liu, Xiaoting [1 ]
Ahn, Kang-Ho [2 ]
Asumadu-Sakyi, Akwasi [1 ]
Fisher, Gavin [3 ]
Gao, Jian [4 ]
Mabon, Adrian [1 ,8 ]
Mazaheri, Mandana [1 ,9 ]
Mullins, Benjamin [6 ]
Nyaku, Mawutorli [1 ]
Ristovski, Zoran [1 ]
Scorgie, Yvonne [5 ]
Phong Thai [1 ,10 ]
Dunbabin, Matthew [7 ]
Morawska, Lidia [1 ]
机构
[1] Queensland Univ Technol, Int Lab Air Qual & Hlth, Brisbane, Qld 4001, Australia
[2] Hanyang Univ, Seoul 04763, South Korea
[3] Environm Protect Author, Carlton, Vic, Australia
[4] Chinese Res Inst Environm Sci, Beijing 100012, Peoples R China
[5] NSW Off Environm & Heritage, Sydney, NSW, Australia
[6] Curtin Univ, Sch Publ Hlth, Perth, WA, Australia
[7] Queensland Univ Technol, Inst Future Environm, Brisbane, Qld, Australia
[8] Ecole Mines Albi Carmaux, Albi, France
[9] NSW Dept Planning & Environm, Sydney, NSW, Australia
[10] Univ Queensland, Queensland Alliance Environm Hlth Sci, Brisbane, Qld, Australia
基金
澳大利亚研究理事会;
关键词
Low-cost sensors; PM sensors; Atmospheric aerosols; Air pollution; PARTICULATE MATTER SENSORS; AIR-QUALITY; LABORATORY EVALUATION; FIELD-EVALUATION; PERFORMANCE; PARTICLE; MONITORS; NETWORK; CALIBRATION; EMISSIONS;
D O I
10.4209/aaqr.2018.10.0390
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recently, there has been a substantial increase in the availability and use of low-cost particulate matter sensors in a wide range of air quality applications. They carry the promise of revolutionising air quality monitoring, yet considerable reservations exist regarding their performance and capabilities, thus hindering the broader-scale utilization of these devices. In order to address these concerns and assess their feasibility and accuracy for various applications, we evaluated six low-cost PM2.5 sensors (the Sharp GP2Y1010AU0F, Shinyei PPD42NS, Plantower PMS1003, Innociple PSM305, Nova SDS011 and Nova SDL607) in laboratory and field conditions using two combustion aerosols, concrete dust and ambient particles. In assessing the performance of these sensors, we focussed on indicators such as the linearity, accuracy and precision, critically differentiating between these qualities, and employed inter-comparison (the coefficient of determination, R-2). In the laboratory, all sensors responded well, with an R-2 > 0.91 when the PM2.5 concentration was > 50 mu g m(-3), as measured by the DustTrak. In particular, the PMS1003 demonstrated good accuracy and precision in both laboratory and ambient conditions. However, some limitations were noted for the tested sensors at lower concentrations. For example, the Sharp and Shinyei sensors showed poor correlations (R-2 < 0.1) with the DustTrak when the ambient PM2.5 concentration was < 20 mu g m(-3). These results suggest that the sensors should be calibrated individually for each source in the environment of their intended use. We demonstrate that when tested appropriately and used with a full understanding of their capabilities and limitations, low-cost sensors can serve as an unprecedented aid in a broad spectrum of air quality applications, including the emerging field of citizen science.
引用
收藏
页码:520 / 532
页数:13
相关论文
共 50 条
  • [1] Evaluation of Low-Cost Sensors for Ambient PM2.5 Monitoring
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    [J]. JOURNAL OF SENSORS, 2018, 2018
  • [2] Towards a hygroscopic growth calibration for low-cost PM2.5 sensors
    Patel, Milan Y.
    Vannucci, Pietro F.
    Kim, Jinsol
    Berelson, William M.
    Cohen, Ronald C.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (03) : 1051 - 1060
  • [3] Evaluating the Performance of Low-Cost PM2.5 Sensors in Mobile Settings
    deSouza, Priyanka
    Wang, An
    Machida, Yuki
    Duhl, Tiffany
    Mora, Simone
    Kumar, Prashant
    Kahn, Ralph
    Ratti, Carlo
    Durant, John L.
    Hudda, Neelakshi
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (41) : 15401 - 15411
  • [4] Analysis of spatiotemporal PM2.5 concentration patterns in Changwon, Korea, using low-cost PM2.5 sensors
    Song, Bonggeun
    Park, Kyunghun
    Kim, Taehyeung
    Seo, Gyeongho
    [J]. URBAN CLIMATE, 2022, 46
  • [5] Assessment of PM2.5 Exposure during Cycle Trips in The Netherlands Using Low-Cost Sensors
    Wesseling, Joost
    Hendricx, Wouter
    de Ruiter, Henri
    van Ratingen, Sjoerd
    Drukker, Derko
    Huitema, Maaike
    Schouwenaar, Claar
    Janssen, Geert
    van Aken, Stephen
    Smeenk, Jan Willem
    Hof, Arjen
    Tielemans, Erik
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (11)
  • [6] LOW-PROCESSING DATA ENRICHMENT AND CALIBRATION FOR PM2.5 LOW-COST SENSORS
    Stojanovi, Danka B.
    Kleut, Duska N.
    Davidovi, Milos D.
    De Vito, Saverio
    Jovasevi-Stojanovi, Milena, V
    Bartonova, Alena
    Lepioufle, Jean-Marie
    [J]. THERMAL SCIENCE, 2023, 27 (3B): : 2229 - 2240
  • [7] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Chu, Hone-Jay
    Ali, Muhammad Zeeshan
    He, Yu-Chen
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [8] Concentration-Temporal Multilevel Calibration of Low-Cost PM2.5 Sensors
    Day, Rong-Fuh
    Yin, Peng-Yeng
    Huang, Yuh-Chin T.
    Wang, Cheng-Yi
    Tsai, Chih-Chun
    Yu, Cheng-Hsien
    [J]. SUSTAINABILITY, 2022, 14 (16)
  • [9] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Hone-Jay Chu
    Muhammad Zeeshan Ali
    Yu-Chen He
    [J]. Scientific Reports, 10
  • [10] Exposure to PM2.5 on Public Transport: Guidance for Field Measurements with Low-Cost Sensors
    Fameli, Kyriaki-Maria
    Moustris, Konstantinos
    Spyropoulos, Georgios
    Rodanas, Dimitrios-Michael
    [J]. ATMOSPHERE, 2024, 15 (03)