Commissioning and clinical evaluation of the IDENTIFYTM surface imaging system for frameless stereotactic radiosurgery

被引:0
|
作者
Covington, Elizabeth L. [1 ,2 ]
Stanley, Dennis N. [1 ]
Sullivan, Rodney J. [1 ]
Riley, Kristen O. [3 ]
Fiveash, John B. [1 ]
Popple, Richard A. [1 ,4 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL USA
[2] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI USA
[3] Univ Alabama Birmingham, Dept Neurosurg, Birmingham, AL USA
[4] Univ Alabama Birmingham, Dept Radiat Oncol, 1719 6th Ave S, Birmingham, AL 35294 USA
来源
关键词
optical surface imaging; SGRT; SRS; stereotactic radiosurgery; surface guided radiation therapy;
D O I
10.1002/acm2.14058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To commission and assess the clinical performance of a new commercial surface imaging (SI) system by analyzing intra-fraction motion from the initial cohort of patients treated with frameless stereotactic radiosurgery (fSRS). Methods: The IDENTIFYTM SI system was commissioned for clinical use on an Edge (VarianMedical Systems, Palo Alto, CA) linear accelerator. All patients who received intracranial radiotherapy with HyperArcTM (Varian Medical Systems, Palo Alto, CA) were immobilized with the EncompassTM (Qfix, Avondale, PA) thermoplastic mask and monitored for intra-fraction motion with SI. IDENTIFYTM log files were correlated with trajectory log files to correlate treatment parameters with SI-reported offsets. IDENTIFYTM reported offsets were correlated with gantry and couch angles to assess system performance for obstructed and clear camera field of view. Data were stratified by race to evaluate performance differences due to skin tone. Results: All commissioning data were found to meet recommended tolerances. IDENTIFYTM was used to monitor intra-fraction motion on 1164 fractions from 386 patients. The median magnitude of translational SI reported offsets at the end of treatment was 0.27 mm. SI reported offsets were shown to increase when camera pods are blocked by the gantry with larger increases seen at nonzero couch angles. With camera obstruction, the median magnitude of the SI reported offset was 0.50 and 0.80 mm forWhite and Black patients, respectively. Conclusions: IDENTIFYTM performance during fSRS is comparable to other commercially available SI systems where offsets are shown to increase at nonzero couch angles and during camera pod blockage.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] The Impact of Imaging Frequency on Intrafraction Setup Corrections in Frameless Image Guided Stereotactic Radiosurgery
    Westerly, D.
    Stuhr, K.
    Altunbas, C.
    Diot, Q.
    Kavanagh, B.
    Miften, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [32] Evaluation of technical performance of optical surface imaging system using conventional and novel stereotactic radiosurgery algorithms
    Kojima, Hironori
    Takemura, Akihiro
    Kurokawa, Shogo
    Ueda, Shinichi
    Noto, Kimiya
    Yokoyama, Haruna
    Takamatsu, Shigeyuki
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 58 - 68
  • [33] A Large Scale Clinical Evaluation of the Effectiveness of Calibration to Reduce Couch-Angle Dependency for Frameless Stereotactic Radiosurgery
    Zhang, L.
    Vijayan, S.
    Song, Y.
    Hipp, E.
    Kuo, H.
    Chan, M.
    Hunt, M.
    Tang, X.
    Li, G.
    MEDICAL PHYSICS, 2019, 46 (06) : E660 - E660
  • [34] The feasibility of frameless stereotactic radiosurgery in the management of pediatric central nervous system tumors
    Ronica Nanda
    Anees Dhabbaan
    Anna Janss
    Hui-Kuo Shu
    Natia Esiashvili
    Journal of Neuro-Oncology, 2014, 117 : 329 - 335
  • [35] Frameless Volumetric Intracranial Stereotactic Radiosurgery with Non-coplanar Arcs: Clinical Experience, Accuracy, and Dosimetric Evaluation
    Garcia, B.
    Sarria, G.
    Martinez, D. A.
    Chumbimuni, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E719 - E719
  • [36] Clinical accuracy of ExacTrac intracranial frameless stereotactic system
    Ackerly, T.
    Lancaster, C. M.
    Geso, M.
    Roxby, K. J.
    MEDICAL PHYSICS, 2011, 38 (09) : 5040 - 5048
  • [37] FRAMELESS IMAGE-GUIDED INTRACRANIAL STEREOTACTIC RADIOSURGERY: CLINICAL OUTCOMES FOR BRAIN METASTASES
    Breneman, John C.
    Steinmetz, Ryan
    Smith, Aaron
    Lamba, Michael
    Warnick, Ronald E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 702 - 706
  • [38] Initial clinical experience with frameless optically guided stereotactic radiosurgery/radiotherapy in pediatric patients
    Keshavarzi, Sassan
    Meltzer, Hal
    Ben-Haim, Sharona
    Newman, Charles Benjamin
    Lawson, Joshua D.
    Levy, Michael L.
    Murphy, Kevin
    CHILDS NERVOUS SYSTEM, 2009, 25 (07) : 837 - 844
  • [39] New findings on clinical experience on surface-guided radiotherapy for frameless non-coplanar stereotactic radiosurgery treatments
    Sanchez-Rubio, Patricia
    Rodriguez-Romero, Ruth
    Pinto-Monedero, Maria
    Alejo-Luque, Luis
    Martinez-Ortega, Jaime
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (12):
  • [40] Initial clinical experience with frameless optically guided stereotactic radiosurgery/radiotherapy in pediatric patients
    Sassan Keshavarzi
    Hal Meltzer
    Sharona Ben-Haim
    Charles Benjamin Newman
    Joshua D Lawson
    Michael L. Levy
    Kevin Murphy
    Child's Nervous System, 2009, 25 : 837 - 844