Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T*

被引:9
|
作者
Niess, Fabian [1 ,4 ]
Strasser, Bernhard [1 ,4 ]
Hingerl, Lukas [1 ,4 ]
Niess, Eva [1 ,2 ]
Motyka, Stanislav [1 ,2 ]
Hangel, Gilbert [1 ,3 ]
Krssak, Martin [4 ]
Gruber, Stephan [1 ,2 ]
Spurny-Dworak, Benjamin [4 ,5 ]
Trattnig, Siegfried [1 ,4 ,6 ]
Scherer, Thomas [4 ]
Lanzenberger, Rupert [4 ,5 ]
Bogner, Wolfgang [1 ,2 ]
机构
[1] Med Univ Vienna, High Field MR Ctr, Dept Biomed Imaging & Image Guided Therapy, Lazarettgasse 14, A-1090 Vienna, Austria
[2] Christian Doppler Lab MR Imaging Biomarkers BIOMAK, Vienna, Austria
[3] Med Univ Vienna, Dept Neurosurg, Vienna, Austria
[4] Med Univ Vienna, Dept Med 3, Div Endocrinol & Metab, Vienna, Austria
[5] Med Univ Vienna, Comprehens Ctr Clin Neurosci & Mental Hlth C3NMH, Dept Psychiat & Psychotherapy, Vienna, Austria
[6] Karl Landsteiner Soc, Inst Clin Mol MRI, 3100St, Polten, Austria
基金
奥地利科学基金会;
关键词
Deuterium metabolic imaging; Quantitative exchange label turnover; Deuterium labeled glucose Clinical 3T; MR spectroscopy; QUANTIFICATION; SPECTROSCOPY; SUPPRESSION; GLUTAMATE; WATER; 3T;
D O I
10.1016/j.neuroimage.2023.120250
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Deuterium metabolic imaging (DMI) and quantitative exchange label turnover (QELT) are novel MR spectroscopy techniques for non-invasive imaging of human brain glucose and neurotransmitter metabolism with high clinical potential. Following oral or intravenous administration of non-ionizing [6,6 & PRIME; -2H2]-glucose, its uptake and synthesis of downstream metabolites can be mapped via direct or indirect detection of deuterium resonances using 2 H MRSI (DMI) and 1 H MRSI (QELT), respectively. The purpose of this study was to compare the dynamics of spatially resolved brain glucose metabolism, i.e., estimated concentration enrichment of deuterium labeled Glx (glutamate +glutamine) and Glc (glucose) acquired repeatedly in the same cohort of subjects using DMI at 7T and QELT at clinical 3T. Methods: Five volunteers (4 m/1f) were scanned in repeated sessions for 60 min after overnight fasting and 0.8 g/kg oral [6,6 & PRIME; -2H2]-glucose administration using time-resolved 3D 2 H FID-MRSI with elliptical phase encod-ing at 7T and 3D 1 H FID-MRSI with a non-Cartesian concentric ring trajectory readout at clinical 3T. Results: One hour after oral tracer administration regionally averaged deuterium labeled Glx4 concentrations and the dynamics were not significantly different over all participants between 7T 2 H DMI and 3T 1 H QELT data for GM (1.29 & PLUSMN; 0.15 vs. 1.38 & PLUSMN; 0.26 mM, p = 0.65 & 21 & PLUSMN; 3 vs. 26 & PLUSMN; 3 & mu;M/min, p = 0.22) and WM (1.10 & PLUSMN; 0.13 vs. 0.91 & PLUSMN; 0.24 mM, p = 0.34 & 19 & PLUSMN; 2 vs. 17 & PLUSMN; 3 & mu;M/min, p = 0.48). Also, the observed time constants of dynamic Glc6 data in GM (24 & PLUSMN; 14 vs. 19 & PLUSMN; 7 min, p = 0.65) and WM (28 & PLUSMN; 19 vs. 18 & PLUSMN; 9 min, p = 0.43) dominated regions showed no significant differences. Between individual 2 H and 1 H data points a weak to moderate negative correlation was observed for Glx4 concentrations in GM ( r = -0.52, p < 0.001), and WM ( r = -0.3, p < 0.001) dominated regions, while a strong negative correlation was observed for Glc6 data GM ( r = -0.61, p < 0.001) and WM ( r = -0.70, p < 0.001). Conclusion: This study demonstrates that indirect detection of deuterium labeled compounds using 1 H QELT MRSI at widely available clinical 3T without additional hardware is able to reproduce absolute concentration estimates of downstream glucose metabolites and the dynamics of glucose uptake compared to 2 H DMI data acquired at 7T. This suggests significant potential for widespread application in clinical settings especially in environments with limited access to ultra-high field scanners and dedicated RF hardware.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Vitamin C estimation with standard 1H spectroscopy using a clinical 3T MR system:: Detectability and reliability within the human brain
    Shih, Yi-Yu
    Buechert, Martin
    Chung, Hsiao-Wen
    Hennig, Juergen
    von Elverfeldt, Dominik
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (02) : 351 - 358
  • [22] Repeatability of simultaneous 3D 1H MRF/23Na MRI in brain at 7 T
    Gonzalo G. Rodriguez
    Zidan Yu
    Lauren F. O′Donnell
    Liz Calderon
    Martijn A. Cloos
    Guillaume Madelin
    Scientific Reports, 12
  • [23] Repeatability of simultaneous 3D 1H MRF/23Na MRI in brain at 7 T
    Rodriguez, Gonzalo G.
    Yu, Zidan
    Calderon, Liz
    Cloos, Martijn A.
    Madelin, Guillaume
    Lauren, F. O.
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [24] Fast high-resolution brain metabolite mapping on a clinical 3T MRI by accelerated 1H-FID-MRSI and low-rank constrained reconstruction
    Klauser, Antoine
    Courvoisier, Sebastien
    Kasten, Jeffrey
    Kocher, Michel
    Guerquin-Kern, Matthieu
    Van De Ville, Dimitri
    Lazeyras, Francois
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 2841 - 2857
  • [25] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Seginer, Amir
    Schmidt, Rita
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Amir Seginer
    Rita Schmidt
    Scientific Reports, 12
  • [27] A comparative study of myo-inositol quantification using LCmodel at 1.5 T and 3.0 T with 3 D 1H proton spectroscopic imaging of the human brain
    Srinivasan, R
    Vigneron, D
    Sailasuta, N
    Hurd, R
    Nelson, S
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 523 - 528
  • [28] Assessment of metabolite quantitation reproducibility in serial 3D-1H-MR spectroscopic Imaging of human brain using sterelotactic repositioning
    Langer, Deanna L.
    Rakaric, Peter
    Kirilova, Anna
    Jaffray, David A.
    Damyanovich, Andrei Z.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) : 666 - 673
  • [29] Editorial for "2D 1H sLASER Long-TE and 3D 31P Chemical Shift Imaging at 3T for Monitoring Fasting-Induced Changes in Brain Tumor Tissue"
    Barker, Peter B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 439 - 440
  • [30] 3D deuterium metabolic imaging (DMI) of the human liver at 7 T using low-rank and subspace model-based reconstruction
    Nam, Kyung Min
    Gursan, Ayhan
    Lee, Nam G.
    Klomp, Dennis W. J.
    Wijnen, Jannie P.
    Prompers, Jeanine J.
    Hendriks, Arjan D.
    Bhogal, Alex A.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) : 1860 - 1873