Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T*

被引:9
|
作者
Niess, Fabian [1 ,4 ]
Strasser, Bernhard [1 ,4 ]
Hingerl, Lukas [1 ,4 ]
Niess, Eva [1 ,2 ]
Motyka, Stanislav [1 ,2 ]
Hangel, Gilbert [1 ,3 ]
Krssak, Martin [4 ]
Gruber, Stephan [1 ,2 ]
Spurny-Dworak, Benjamin [4 ,5 ]
Trattnig, Siegfried [1 ,4 ,6 ]
Scherer, Thomas [4 ]
Lanzenberger, Rupert [4 ,5 ]
Bogner, Wolfgang [1 ,2 ]
机构
[1] Med Univ Vienna, High Field MR Ctr, Dept Biomed Imaging & Image Guided Therapy, Lazarettgasse 14, A-1090 Vienna, Austria
[2] Christian Doppler Lab MR Imaging Biomarkers BIOMAK, Vienna, Austria
[3] Med Univ Vienna, Dept Neurosurg, Vienna, Austria
[4] Med Univ Vienna, Dept Med 3, Div Endocrinol & Metab, Vienna, Austria
[5] Med Univ Vienna, Comprehens Ctr Clin Neurosci & Mental Hlth C3NMH, Dept Psychiat & Psychotherapy, Vienna, Austria
[6] Karl Landsteiner Soc, Inst Clin Mol MRI, 3100St, Polten, Austria
基金
奥地利科学基金会;
关键词
Deuterium metabolic imaging; Quantitative exchange label turnover; Deuterium labeled glucose Clinical 3T; MR spectroscopy; QUANTIFICATION; SPECTROSCOPY; SUPPRESSION; GLUTAMATE; WATER; 3T;
D O I
10.1016/j.neuroimage.2023.120250
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Deuterium metabolic imaging (DMI) and quantitative exchange label turnover (QELT) are novel MR spectroscopy techniques for non-invasive imaging of human brain glucose and neurotransmitter metabolism with high clinical potential. Following oral or intravenous administration of non-ionizing [6,6 & PRIME; -2H2]-glucose, its uptake and synthesis of downstream metabolites can be mapped via direct or indirect detection of deuterium resonances using 2 H MRSI (DMI) and 1 H MRSI (QELT), respectively. The purpose of this study was to compare the dynamics of spatially resolved brain glucose metabolism, i.e., estimated concentration enrichment of deuterium labeled Glx (glutamate +glutamine) and Glc (glucose) acquired repeatedly in the same cohort of subjects using DMI at 7T and QELT at clinical 3T. Methods: Five volunteers (4 m/1f) were scanned in repeated sessions for 60 min after overnight fasting and 0.8 g/kg oral [6,6 & PRIME; -2H2]-glucose administration using time-resolved 3D 2 H FID-MRSI with elliptical phase encod-ing at 7T and 3D 1 H FID-MRSI with a non-Cartesian concentric ring trajectory readout at clinical 3T. Results: One hour after oral tracer administration regionally averaged deuterium labeled Glx4 concentrations and the dynamics were not significantly different over all participants between 7T 2 H DMI and 3T 1 H QELT data for GM (1.29 & PLUSMN; 0.15 vs. 1.38 & PLUSMN; 0.26 mM, p = 0.65 & 21 & PLUSMN; 3 vs. 26 & PLUSMN; 3 & mu;M/min, p = 0.22) and WM (1.10 & PLUSMN; 0.13 vs. 0.91 & PLUSMN; 0.24 mM, p = 0.34 & 19 & PLUSMN; 2 vs. 17 & PLUSMN; 3 & mu;M/min, p = 0.48). Also, the observed time constants of dynamic Glc6 data in GM (24 & PLUSMN; 14 vs. 19 & PLUSMN; 7 min, p = 0.65) and WM (28 & PLUSMN; 19 vs. 18 & PLUSMN; 9 min, p = 0.43) dominated regions showed no significant differences. Between individual 2 H and 1 H data points a weak to moderate negative correlation was observed for Glx4 concentrations in GM ( r = -0.52, p < 0.001), and WM ( r = -0.3, p < 0.001) dominated regions, while a strong negative correlation was observed for Glc6 data GM ( r = -0.61, p < 0.001) and WM ( r = -0.70, p < 0.001). Conclusion: This study demonstrates that indirect detection of deuterium labeled compounds using 1 H QELT MRSI at widely available clinical 3T without additional hardware is able to reproduce absolute concentration estimates of downstream glucose metabolites and the dynamics of glucose uptake compared to 2 H DMI data acquired at 7T. This suggests significant potential for widespread application in clinical settings especially in environments with limited access to ultra-high field scanners and dedicated RF hardware.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Dynamic 1H-MRS for detection of 13C-labeled glucose metabolism in the human brain at 3T
    Dehghani, Masoumeh
    Zhang, Steven
    Kumaragamage, Chathura
    Rosa-Neto, Pedro
    Near, Jamie
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1140 - 1151
  • [2] Noninvasive 3-Dimensional 1H-Magnetic Resonance Spectroscopic Imaging of Human Brain Glucose and Neurotransmitter Metabolism Using Deuterium Labeling at 3T Feasibility and Interscanner Reproducibility
    Niess, Fabian
    Hingerl, Lukas
    Strasser, Bernhard
    Bednarik, Petr
    Goranovic, Dario
    Niess, Eva
    Hangel, Gilbert
    Krssak, Martin
    Spurny-Dworak, Benjamin
    Scherer, Thomas
    Lanzenberger, Rupert
    Bogner, Wolfgang
    INVESTIGATIVE RADIOLOGY, 2023, 58 (06) : 431 - 437
  • [3] Deuterium metabolic imaging for 3D mapping of glucose metabolism in humans with central nervous system lesions at 3T
    Adamson, Philip M.
    Datta, Keshav
    Watkins, Ron
    Recht, Lawrence D.
    Hurd, Ralph E.
    Spielman, Daniel M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (01) : 39 - 50
  • [4] Whole-brain 3D FLAIR at 7T using direct signal control
    Beqiri, Arian
    Hoogduin, Hans
    Sbrizzi, Alessandro
    Hajnal, Joseph V.
    Malik, Shaihan J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1533 - 1545
  • [5] 3D-1H-MRSI metabolite quantitation reproducibility in human brain using a stereotactic immobilizationfrepositioning device
    Langer, D.
    Jaywant, S.
    Rakaric, P.
    Kirilova, A.
    Damyanovich, A.
    EJC SUPPLEMENTS, 2005, 3 (02): : 411 - 412
  • [6] Synthesized 7T MPRAGE From 3T MPRAGE Using Generative Adversarial Network and Validation in Clinical Brain Imaging: A Feasibility Study
    Duan, Caohui
    Bian, Xiangbing
    Cheng, Kun
    Lyu, Jinhao
    Xiong, Yongqin
    Xiao, Sa
    Wang, Xueyang
    Duan, Qi
    Li, Chenxi
    Huang, Jiayu
    Hu, Jianxing
    Wang, Z. Jane
    Zhou, Xin
    Lou, Xin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (05) : 1620 - 1629
  • [7] Reproducibility of 3D 1H MR spectroscopic imaging of the prostate at 1.5T
    Lagemaat, Miriam W.
    Zechmann, Christian M.
    Futterer, Jurgen J.
    Weiland, Elisabeth
    Lu, Jianping
    Villeirs, Geert M.
    Holshouser, Barbara A.
    van Hecke, Paul
    Lemort, Marc
    Schlemmer, Heinz-Peter
    Barentsz, Jelle O.
    Roell, Stefan O.
    Heerschap, Arend
    Scheenen, Tom W. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (01) : 166 - 173
  • [8] Short Echo Time 1H MRSI of the Human Brain at 3T With Adiabatic Slice-Selective Refocusing Pulses; Reproducibility and Variance in a Dual Center Setting
    Wijnen, Jannie R.
    van Asten, Jack J. A.
    Klomp, Dennis W. J.
    Sjobakk, Torill E.
    Gribbestad, Ingrid S.
    Scheenen, Tom W. J.
    Heerschap, Arend
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 61 - 70
  • [9] 1H magnetic resonance spectroscopic imaging of deuterated glucose and of neurotransmitter metabolism at 7 T in the human brain
    Petr Bednarik
    Dario Goranovic
    Alena Svatkova
    Fabian Niess
    Lukas Hingerl
    Bernhard Strasser
    Dinesh K. Deelchand
    Benjamin Spurny-Dworak
    Martin Krssak
    Siegfried Trattnig
    Gilbert Hangel
    Thomas Scherer
    Rupert Lanzenberger
    Wolfgang Bogner
    Nature Biomedical Engineering, 2023, 7 : 1001 - 1013
  • [10] 1H magnetic resonance spectroscopic imaging of deuterated glucose and of neurotransmitter metabolism at 7 T in the human brain
    Bednarik, Petr
    Goranovic, Dario
    Svatkova, Alena
    Niess, Fabian
    Hingerl, Lukas
    Strasser, Bernhard
    Deelchand, Dinesh K. K.
    Spurny-Dworak, Benjamin
    Krssak, Martin
    Trattnig, Siegfried
    Hangel, Gilbert
    Scherer, Thomas
    Lanzenberger, Rupert
    Bogner, Wolfgang
    NATURE BIOMEDICAL ENGINEERING, 2023, 7 (08) : 1001 - 1013