Experimental Study on the Structural Performance of Reinforced Truss Concrete Composite Slabs during and after Fire

被引:2
|
作者
Li, Bing [1 ]
Li, Zhengshang [1 ]
Chen, Zhijun [2 ]
Yang, Zhoulin [1 ]
Zhang, Yang [1 ]
机构
[1] Hainan Univ, Coll Civil Engn & Architecture, Haikou 570228, Peoples R China
[2] Haikou Qiongshan Dist Fire & Rescue Brigade, Haikou 570228, Peoples R China
关键词
composite slab; separated seam; fire-resistant performance; residual bearing capacity; ultimate deformation; MODELING MEMBRANE ACTION; BUILDINGS; BEHAVIOR; AMBIENT;
D O I
10.3390/buildings13071615
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Standard fire resistance tests and post-fire tests on residual mechanical properties were carried out on two four-edge simply supported reinforced truss concrete two-way composite slabs with wide seam splicing ("integral seam") and close seam splicing ("separated seam"), and the effects of the different splicing forms on the mechanical properties of the reinforced truss concrete composite slabs during and after exposure to high temperatures were explored. The results indicate that there are significant differences in terms of crack developments, moisture loss times on the slab surface, spalling characteristics of the bottom of the slab and cross-section temperature gradients of concrete and steel reinforcement along the thickness direction between the wide seam spliced reinforced truss concrete composite two-way slab (referred to as "S1 composite slab") and the close seam spliced reinforced truss concrete composite two-way slab (referred to as "S2 composite slab") in the fire test. This is mainly due to differences in the splicing forms and structural measures of the prefabricated base slabs at joints, which led to changes in the heat transfer path at the joints. As the temperature at the close seam can be released quickly, the stiffness recovery of the S2 composite slab is significantly greater than the stiffness weakening due to the thermal hysteresis of the concrete, so the deflection of the S2 composite slab recovers immediately after the fire stops. Overall, both the S1 and S2 composite slabs exhibit two-way high temperature deformation characteristics. The post-fire residual static load tests show that the static load-carrying capacity of the S1 composite slab is 12.08% higher than that of the S2 composite slab and the ultimate displacement is 8.74% lower than that of the S2 composite slab. It is appropriate to calculate the residual load capacities of the S1 and S2 composite slabs after the fire as a one-way slab.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Experimental Study of In-Plane Shear Behavior of Fiber-Reinforced Concrete Composite Slabs
    Altoubat, Salah
    Ousmane, Hisseine
    Barakat, Samer
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [42] Experimental study on concrete spalling in prestressed slabs subjected to fire
    Zheng, W. Z.
    Hou, X. M.
    Shi, D. S.
    Xu, M. X.
    FIRE SAFETY JOURNAL, 2010, 45 (05) : 283 - 297
  • [43] Experimental study on fire resistance of steel truss-concrete composite bridge girder under HC fire conditions
    Tang C.
    Zhang G.
    Li X.
    Lu Z.
    Song C.
    Wang S.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (03): : 160 - 173
  • [44] Structural performance of self-compacting lightweight reinforced concrete slabs
    El-Ghandour, A.A.
    Zaher, A.A.
    Abdelrahman, A.A.
    Sultan, R.
    Journal of Engineering and Applied Science, 2010, 57 (06): : 491 - 509
  • [45] An experimental study on structural fire behavior of reinforced concrete wall after high velocity impact of hard projectile
    Morita, Takeshi
    Beppu, Masuhiro
    Suzuki, Makoto
    Journal of Structural and Construction Engineering, 2015, 80 (708): : 357 - 367
  • [46] Research on Structural Performance of Hybrid Ferro Fiber Reinforced Concrete Slabs
    Saeed, Hafiz Zain
    Saleem, Muhammad Zubair
    Chua, Yie Sue
    Vatin, Nikolai Ivanovich
    MATERIALS, 2022, 15 (19)
  • [47] An experimental study on the structural performance of the composite slabs with the new-type deckplate
    Yoon, MH
    Choi, CS
    Kim, DK
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 1049 - 1056
  • [48] Experimental and Numerical Investigation of the Structural, Thermal and Acoustic Performance of Reinforced Concrete Slabs with Balls for a Cleaner Environment
    Musa Hakan Arslan
    Yasin Onuralp Özkılıç
    H. Derya Arslan
    Ömer Sinan Şahin
    International Journal of Civil Engineering, 2023, 21 : 789 - 804
  • [49] Experimental Study on the Cyclic Performance of Reinforced Concrete Shear Walls Exposed to Fire
    Ryu, Eunmi
    Kim, Heesun
    Shin, Yeongsoo
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2020, 14 (01)
  • [50] Fire performance of earthquake-damaged reinforced concrete columns: an experimental study
    Chinthapalli, Hemanth Kumar
    Agarwal, Anil
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (01) : 67 - 87