Experimental Study on the Structural Performance of Reinforced Truss Concrete Composite Slabs during and after Fire

被引:2
|
作者
Li, Bing [1 ]
Li, Zhengshang [1 ]
Chen, Zhijun [2 ]
Yang, Zhoulin [1 ]
Zhang, Yang [1 ]
机构
[1] Hainan Univ, Coll Civil Engn & Architecture, Haikou 570228, Peoples R China
[2] Haikou Qiongshan Dist Fire & Rescue Brigade, Haikou 570228, Peoples R China
关键词
composite slab; separated seam; fire-resistant performance; residual bearing capacity; ultimate deformation; MODELING MEMBRANE ACTION; BUILDINGS; BEHAVIOR; AMBIENT;
D O I
10.3390/buildings13071615
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Standard fire resistance tests and post-fire tests on residual mechanical properties were carried out on two four-edge simply supported reinforced truss concrete two-way composite slabs with wide seam splicing ("integral seam") and close seam splicing ("separated seam"), and the effects of the different splicing forms on the mechanical properties of the reinforced truss concrete composite slabs during and after exposure to high temperatures were explored. The results indicate that there are significant differences in terms of crack developments, moisture loss times on the slab surface, spalling characteristics of the bottom of the slab and cross-section temperature gradients of concrete and steel reinforcement along the thickness direction between the wide seam spliced reinforced truss concrete composite two-way slab (referred to as "S1 composite slab") and the close seam spliced reinforced truss concrete composite two-way slab (referred to as "S2 composite slab") in the fire test. This is mainly due to differences in the splicing forms and structural measures of the prefabricated base slabs at joints, which led to changes in the heat transfer path at the joints. As the temperature at the close seam can be released quickly, the stiffness recovery of the S2 composite slab is significantly greater than the stiffness weakening due to the thermal hysteresis of the concrete, so the deflection of the S2 composite slab recovers immediately after the fire stops. Overall, both the S1 and S2 composite slabs exhibit two-way high temperature deformation characteristics. The post-fire residual static load tests show that the static load-carrying capacity of the S1 composite slab is 12.08% higher than that of the S2 composite slab and the ultimate displacement is 8.74% lower than that of the S2 composite slab. It is appropriate to calculate the residual load capacities of the S1 and S2 composite slabs after the fire as a one-way slab.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Blast performance of reinforced concrete hollow core slabs in combination with fire: Numerical and experimental assessment
    Kakogiannis, Dimitrios
    Pascualena, Fermin
    Reymen, Bruno
    Pyl, Lincy
    Ndambi, Jean Marie
    Segers, Eric
    Lecompte, David
    Vantomme, John
    Krauthammer, Ted
    FIRE SAFETY JOURNAL, 2013, 57 : 69 - 82
  • [22] Experimental Study on Fire Performance of Loaded Reinforced Concrete Beams
    Singh, Dharmendra
    Singh, Suvir
    Bhattacharyya, S. K.
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 738 - 746
  • [23] Experimental study on shear behavior of interface of composite reinforced concrete walls with reinforcement truss
    Pi Z.
    Liao X.
    Wei Q.
    Wang Y.
    Chen H.
    Zhang H.
    Wang S.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (07): : 146 - 153
  • [24] Modeling the performance of reinforced concrete slabs cast with high-performance concrete under fire
    Ghazy, Mariam F.
    Abd Elaty, Metwally A.
    Zalhaf, Nagat M.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (02)
  • [25] Modeling the performance of reinforced concrete slabs cast with high-performance concrete under fire
    Mariam F. Ghazy
    Metwally A. Abd Elaty
    Nagat M. Zalhaf
    Innovative Infrastructure Solutions, 2022, 7
  • [26] Performance of reinforced concrete slabs subjected to simultaneous fire and blast loads
    Li, Huawei
    Chen, Wensu
    Hao, Hong
    ENGINEERING STRUCTURES, 2024, 311
  • [27] Strength and performance of fiber-reinforced concrete composite slabs
    Roberts-Wollmann, CL
    Guirola, M
    Easterling, WS
    JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (03) : 520 - 528
  • [28] An experimental study on strength and serviceability of reinforced and steel fibre reinforced concrete (SFRC) continuous composite slabs
    Gholamhoseini, Alireza
    Khanlou, Amir
    MacRae, Gregory
    Scott, Allan
    Hicks, Stephen
    Leon, Roberto
    ENGINEERING STRUCTURES, 2016, 114 : 171 - 180
  • [29] Experimental study on the mechanical behavior of composite beams with superposed slabs after fire
    Lü, Jun-Li
    Zhou, Sheng-Nan
    Lü, Jing-Jing
    Cai, Yong-Yuan
    Chen, Qi-Chao
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 (01): : 220 - 230
  • [30] Experimental research of fire performance on reinforced concrete slabs strengthened with CFRP sheets bonded with inorganic adhesive
    Zheng, Wenzhong
    Wan, Fuxiong
    Li, Shiguang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (10): : 89 - 97