Experimental Study on the Structural Performance of Reinforced Truss Concrete Composite Slabs during and after Fire

被引:2
|
作者
Li, Bing [1 ]
Li, Zhengshang [1 ]
Chen, Zhijun [2 ]
Yang, Zhoulin [1 ]
Zhang, Yang [1 ]
机构
[1] Hainan Univ, Coll Civil Engn & Architecture, Haikou 570228, Peoples R China
[2] Haikou Qiongshan Dist Fire & Rescue Brigade, Haikou 570228, Peoples R China
关键词
composite slab; separated seam; fire-resistant performance; residual bearing capacity; ultimate deformation; MODELING MEMBRANE ACTION; BUILDINGS; BEHAVIOR; AMBIENT;
D O I
10.3390/buildings13071615
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Standard fire resistance tests and post-fire tests on residual mechanical properties were carried out on two four-edge simply supported reinforced truss concrete two-way composite slabs with wide seam splicing ("integral seam") and close seam splicing ("separated seam"), and the effects of the different splicing forms on the mechanical properties of the reinforced truss concrete composite slabs during and after exposure to high temperatures were explored. The results indicate that there are significant differences in terms of crack developments, moisture loss times on the slab surface, spalling characteristics of the bottom of the slab and cross-section temperature gradients of concrete and steel reinforcement along the thickness direction between the wide seam spliced reinforced truss concrete composite two-way slab (referred to as "S1 composite slab") and the close seam spliced reinforced truss concrete composite two-way slab (referred to as "S2 composite slab") in the fire test. This is mainly due to differences in the splicing forms and structural measures of the prefabricated base slabs at joints, which led to changes in the heat transfer path at the joints. As the temperature at the close seam can be released quickly, the stiffness recovery of the S2 composite slab is significantly greater than the stiffness weakening due to the thermal hysteresis of the concrete, so the deflection of the S2 composite slab recovers immediately after the fire stops. Overall, both the S1 and S2 composite slabs exhibit two-way high temperature deformation characteristics. The post-fire residual static load tests show that the static load-carrying capacity of the S1 composite slab is 12.08% higher than that of the S2 composite slab and the ultimate displacement is 8.74% lower than that of the S2 composite slab. It is appropriate to calculate the residual load capacities of the S1 and S2 composite slabs after the fire as a one-way slab.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Experimental study on behaviors of reinforced concrete slabs after fire
    Wang, ZQ
    Yu, ZW
    Yu, F
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A AND B, 2004, 4 : 1252 - 1256
  • [2] The Fire Performance of Polymer Fibre Reinforced Composite Concrete Slabs
    Fox, D.
    Stratford, T.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 278 - 285
  • [3] Experimental study of fire damage to reinforced concrete tunnel slabs
    Hua, Nan
    Khorasani, Negar Elhami
    Tessari, Anthony
    Ranade, Ravi
    FIRE SAFETY JOURNAL, 2022, 127
  • [4] Finite element analysis of flexural performance of reinforced truss hollow composite concrete slabs
    Xudong Chen
    Yunlin Liu
    Qinyong Ma
    Peng Zhou
    Xuan Liu
    Jiajian Lin
    Scientific Reports, 15 (1)
  • [5] EXPERIMENTAL STUDY ON FIRE RESISTANCE OF REINFORCED CONCRETE SUPERIMPOSED SLABS WITH FOUR SIDES SIMPLY SUPPORTED BY STEEL BAR TRUSS
    Zhao K.-Z.
    Wei X.
    Ren X.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (06): : 122 - 130
  • [6] Experimental study on residual performance of reinforced concrete beams after fire
    Xu, Y. (yuyexu@hqu.edu.cn), 1600, Science Press (34):
  • [7] Study on the Method for Calculating the Flexural Rigidity of Reinforced Concrete Truss Hollow Composite Slabs
    Chen, Xudong
    Liu, Yunlin
    Ma, Qinyong
    Wu, Deyi
    Shi, Guodong
    BUILDINGS, 2025, 15 (04)
  • [8] Structural behaviour of FRP reinforced concrete slabs in fire
    Bilotta, Antonio
    Compagnone, Alberto
    Esposito, Laura
    Nigro, Emidio
    ENGINEERING STRUCTURES, 2020, 221 (221)
  • [9] Experimental research and FEA on fire resistance performance of precast concrete composite slabs
    Zhou, Xuhong
    Deng, Libin
    Wu, Fangbo
    Liu, Biao
    Li, Jun
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (12): : 82 - 90
  • [10] Experimental study of two-way reinforced concrete slabs under fire
    Wang, Bin
    Dong, Yuli
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (04): : 53 - 62