On the Nature of Stationary and Time-Resolved Fluorescence Spectroscopy of Collagen Powder from Bovine Achilles Tendon

被引:1
|
作者
Saletnik, Lukasz [1 ]
Szczesny, Wojciech [2 ]
Szmytkowski, Jakub [2 ]
Fisz, Jacek J. J. [1 ]
机构
[1] Nicolaus Copernicus Univ, Coll Med, Fac Hlth Sci, PL-85067 Bydgoszcz, Poland
[2] Nicolaus Copernicus Univ, Coll Med, Fac Med, PL-85067 Bydgoszcz, Poland
关键词
collagen; collagen cross-links; fluorescence stationary spectroscopy; fluorescence time-resolved spectroscopy; fluorescence excitation energy transfer; SKIN; MARKERS;
D O I
10.3390/ijms24087631
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a more systematic study of steady-state and time-resolved autofluorescence spectroscopy of collagen isolated from bovine Achilles tendon. In steady-state fluorescence measurements, the excitation and emission spectra of collagen powder, recorded at different fluorescence excitation and detection wavelengths, were compared with the fluorescence excitation and emission spectra of the amino acids phenylalanine, tyrosine, and tryptophan, as well as with similar spectra for 13 autofluorescent collagen cross-links, which have been identified and described in the literature so far. In time-resolved studies, fluorescence was excited by the pulsed light of different wavelengths, and for each excitation wavelength, fluorescence decay was recorded for several detection wavelengths. Data analysis allowed recovery of the fluorescence decay times for each experimental excitation detection event. The obtained information on the decay times of the measured fluorescent signals was discussed, taking into account the available literature data from similar studies of isolated collagen and collagen-rich tissues. Based on the obtained results, it was found that the shape and position of the measured fluorescence excitation and emission spectra of collagen strongly depend on the emission and excitation wavelengths selected in the measurements. From the recorded excitation and emission bands of collagen, it can be concluded with high probability that there are additional, so far unidentified, collagen cross-links, which can be excited at longer excitation wavelengths. In addition, the collagen excitation spectra were measured at longer emission wavelengths at which the collagen cross-links emit fluorescent light. In addition to the emission spectra obtained for excitation in the deep-UV region, the results of time-resolved fluorescence studies with excitation in the deep-UV region and detection at longer wavelengths suggest that fluorescence excitation energy transfer processes occur from the amino acids to the collagen cross-links, and also between the cross-links themselves.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Time-resolved fluorescence spectroscopy of human brain tumors
    Marcu, L
    Thompson, RC
    Garde, S
    Sedrak, M
    Black, KL
    Yong, WH
    OPTICAL BIOPSY IV, 2002, 4613 : 183 - 187
  • [32] Time-resolved fluorescence spectroscopy meningiomas brain tumors
    Butte, P
    Pikul, B
    Yong, W
    Black, K
    Marcu, L
    LASERS IN SURGERY AND MEDICINE, 2003, : 52 - 52
  • [33] Time-resolved fluorescence spectroscopy for illuminating complex systems
    Bright, FV
    Munson, CA
    ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) : 71 - 104
  • [34] Fluorescence Dynamics of LicT Protein by Time-Resolved Spectroscopy
    Chang Meng-Fang
    Li Lei
    Cao Xiao-Dan
    Jia Meng-Hui
    Zhou Jia-Sheng
    Chen Jin-Quan
    Xu Jian-Hua
    ACTA PHYSICO-CHIMICA SINICA, 2017, 33 (05) : 1065 - 1070
  • [35] TIME-RESOLVED FLUORESCENCE SPECTROSCOPY OF CRUDE OILS AND CONDENSATES
    GANGOPADHYAY, S
    LANDIS, CR
    PLEIL, MW
    BORST, WL
    MUKHOPADHYAY, PK
    FUEL, 1988, 67 (12) : 1674 - 1679
  • [36] Pitfalls and Their Remedies in Time-Resolved Fluorescence Spectroscopy and Microscopy
    Martin vandeVen
    Marcel Ameloot
    Bernard Valeur
    Noël Boens
    Journal of Fluorescence, 2005, 15 : 377 - 413
  • [37] TIME-RESOLVED FLUORESCENCE SPECTROSCOPY USING PULSED LASERS
    GHIGGINO, KP
    ROBERTS, AJ
    PHILLIPS, D
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (04): : 446 - 450
  • [38] Time-resolved all fiber fluorescence spectroscopy system
    Chen, A. Y. H.
    Vanholsbeeck, F.
    Tai, D. C. S.
    Svrcek, M.
    Smaill, B. H.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [39] Time-resolved all fiber fluorescence spectroscopy system
    Chen, A. Y. H.
    Vanholsbeeck, F.
    Tai, D. C. S.
    Swift, S.
    Singhal, N.
    Harvey, J. D.
    Hooks, D. A.
    Smaill, B. H.
    19TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2008, 7004
  • [40] IMMUNOASSAYS WITH TIME-RESOLVED FLUORESCENCE SPECTROSCOPY - PRINCIPLES AND APPLICATIONS
    DIAMANDIS, EP
    CLINICAL BIOCHEMISTRY, 1988, 21 (03) : 139 - 150