Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors

被引:0
|
作者
Li, Xiangyu [1 ]
Wang, Pengjun [1 ]
Ye, Hao [1 ]
He, Haonan [2 ]
Zhang, Xiaowei [2 ]
机构
[1] Wenzhou Univ, Coll Elect & Elect Engn, Wenzhou 325035, Peoples R China
[2] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Peoples R China
基金
中国国家自然科学基金;
关键词
high precision; read-out circuits; sigma-delta modulator; digital filter; SIGMA-DELTA-MODULATOR; ACCELEROMETER; INTERFACE; QUANTIZER;
D O I
10.3390/mi14112013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bridge sensors are widely used in military and civilian fields, and their demand gradually increases each year. Digital sensors are widely used in the military and civilian fields. High-precision and low-power analog-to-digital converters (ADCs) as sensor read-out circuits are a research hotspot. Sigma-delta ADC circuits based on switched-capacitor topology have the advantages of high signal-to-noise ratio (SNR), good linearity, and better compatibility with CMOS processes. In this work, a fourth-order feed-forward sigma-delta modulator and a digital decimation filter are designed and implemented with a correlated double sampling technique (CDS) to suppress pre-integrator low-frequency noise. This work used an active pre-compensator circuit for deep phase compensation to improve the system's stability in the sigma-delta modulator. The modulator's local feedback factor is designed to be adjustable off-chip to eliminate the effect of process errors. A three-stage cascade structure was chosen for the post-stage digital filter, significantly reducing the number of operations and the required memory cells in the digital circuit. Finally, the layout design and engineering circuit were fabricated by a standard 0.35 mu m CMOS process from Shanghai Hua Hong with a chip area of 9 mm2. At a 5 V voltage supply and sampling frequency of 6.144 MHz, the modulator power consumption is 13 mW, the maximum input signal amplitude is -3 dBFs, the 1 Hz dynamic range is about 118 dB, the modulator signal-to-noise ratio can reach 110.5 dB when the signal bandwidth is 24 kHz, the practical bit is about 18.05 bits, and the harmonic distortion is about -113 dB, which meets the design requirements. The output bit stream is 24 bits.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [41] An Ultra-Low-Power Read-Out Circuit for Interfacing Novel Gas Sensors Matrices
    Puyol, Rafael
    Petre, Sylvain
    Danlee, Yann
    Walewyns, Thomas
    Francis, Laurent A.
    Flandre, Denis
    IEEE SENSORS JOURNAL, 2022, 22 (10) : 9521 - 9533
  • [42] Energy-Efficient Read-Out IC for High-Precision DC Measurement System with Instrumentation Amplifier Power Reduction Technique
    Shin, Sangmin
    Kim, Minsung
    Park, Junyoung
    Lee, Hyunjoong
    Kim, Suhwan
    2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2021,
  • [43] Experiments and simulations on a few-electron quantum dot circuit with integrated charge read-out
    Hanson, R
    Elzerman, JM
    van Beveren, LHW
    Vandersypen, LMK
    Zhang, LX
    Matagne, P
    Leburton, JP
    Kouwenhoven, LP
    PHYSICS OF SEMICONDUCTORS, PTS A AND B, 2005, 772 : 44 - 49
  • [44] MEMS with integrated CMOS read-out circuit based on submicrometric cantilevers array for multiple sensing
    Villarroya, M
    Verd, J
    Teva, J
    Abadal, G
    Figueras, E
    Pérez-Murano, F
    Esteve, J
    Barniol, N
    Smart Sensors, Actuators, and MEMS II, 2005, 5836 : 78 - 85
  • [45] Efficient Implementation of High Performance Read out Integrated Circuit
    Gupta, Hari Shanker
    Chakrabarti, Subhananda
    Baghini, Maryam Shojaei
    Sharma, D. K.
    Kumar, A. S. Kiran
    Mehta, Sanjeev
    Paul, Sandip
    Chaurasia, Ravi Shankar
    Roychowdhury, A.
    2014 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2014,
  • [46] The read-out driver for the ATLAS MDT muon precision chambers
    Boterenbrood, H.
    Jansweijer, P.
    Kieft, G.
    Konig, A.
    Vermeulen, J.
    Wijnen, T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 741 - 748
  • [47] A Power-Efficient Capacitive Read-Out Circuit With Parasitic-Cancellation for MEMS Cochlea Sensors
    Wang, Shiwei
    Koickal, Thomas Jacob
    Hamilton, Alister
    Mastropaolo, Enrico
    Cheung, Rebecca
    Abel, Andrew
    Smith, Leslie S.
    Wang, Lei
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (01) : 25 - 37
  • [48] A low power, low voltage current read-out circuit for implantable electro-chemical sensors
    Huque, M. A.
    Haider, M. R.
    Zhang, Mo
    Oh, Taeho
    Islam, Syed K.
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 64 - 67
  • [49] ISFET sensor coupled with CMOS read-out circuit microsystem
    Ravezzi, L
    Conci, P
    ELECTRONICS LETTERS, 1998, 34 (23) : 2234 - 2235
  • [50] High resolution read-out circuit for DNA label-free detection system
    De Venuto, Daniela
    Ricco, Bruno
    ISQED 2008: PROCEEDINGS OF THE NINTH INTERNATIONAL SYMPOSIUM ON QUALITY ELECTRONIC DESIGN, 2008, : 708 - +