Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors

被引:0
|
作者
Li, Xiangyu [1 ]
Wang, Pengjun [1 ]
Ye, Hao [1 ]
He, Haonan [2 ]
Zhang, Xiaowei [2 ]
机构
[1] Wenzhou Univ, Coll Elect & Elect Engn, Wenzhou 325035, Peoples R China
[2] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Peoples R China
基金
中国国家自然科学基金;
关键词
high precision; read-out circuits; sigma-delta modulator; digital filter; SIGMA-DELTA-MODULATOR; ACCELEROMETER; INTERFACE; QUANTIZER;
D O I
10.3390/mi14112013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bridge sensors are widely used in military and civilian fields, and their demand gradually increases each year. Digital sensors are widely used in the military and civilian fields. High-precision and low-power analog-to-digital converters (ADCs) as sensor read-out circuits are a research hotspot. Sigma-delta ADC circuits based on switched-capacitor topology have the advantages of high signal-to-noise ratio (SNR), good linearity, and better compatibility with CMOS processes. In this work, a fourth-order feed-forward sigma-delta modulator and a digital decimation filter are designed and implemented with a correlated double sampling technique (CDS) to suppress pre-integrator low-frequency noise. This work used an active pre-compensator circuit for deep phase compensation to improve the system's stability in the sigma-delta modulator. The modulator's local feedback factor is designed to be adjustable off-chip to eliminate the effect of process errors. A three-stage cascade structure was chosen for the post-stage digital filter, significantly reducing the number of operations and the required memory cells in the digital circuit. Finally, the layout design and engineering circuit were fabricated by a standard 0.35 mu m CMOS process from Shanghai Hua Hong with a chip area of 9 mm2. At a 5 V voltage supply and sampling frequency of 6.144 MHz, the modulator power consumption is 13 mW, the maximum input signal amplitude is -3 dBFs, the 1 Hz dynamic range is about 118 dB, the modulator signal-to-noise ratio can reach 110.5 dB when the signal bandwidth is 24 kHz, the practical bit is about 18.05 bits, and the harmonic distortion is about -113 dB, which meets the design requirements. The output bit stream is 24 bits.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A low power read-out integrated circuit for multiple sensors
    Huang, Gongxing
    Wei, Rongshan
    Wang, Wanjin
    Chen, Qunchao
    [J]. IEICE ELECTRONICS EXPRESS, 2020, 17 (17): : 1 - 6
  • [2] A Bidirectional Circuit for Actuation and Read-out of Resonating Sensors
    Azadmehr, Mehdi
    Khajeh, Belal K.
    Berg, Yngvar
    [J]. 2014 IEEE FAIBLE TENSION FAIBLE CONSOMMATION (FTFC), 2014,
  • [3] Methods of canceling noises in CMOS read-out integrated circuit
    Shen, Xiao-Yan
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2004, 33 (06): : 659 - 661
  • [4] Environmental sensors based on micromachined cantilevers with integrated read-out
    Boisen, A
    Thaysen, J
    Jensenius, H
    Hansen, O
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 11 - 16
  • [5] Novel Thermal Flow Sensors Based on a Wheatstone Bridge Read-out
    Talic, A.
    Cerimovic, S.
    Beigelbeck, R.
    Kohl, F.
    Jachimowicz, A.
    Keplinger, F.
    [J]. PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 136 - +
  • [6] A discrete implementation of a bidirectional circuit for actuation and read-out of resonating sensors
    Marchetti, Luca
    Romi, Amar
    Berg, Yngvar
    Mirmotahari, Omid
    Azadmehr, Mehdi
    [J]. 2016 11TH IEEE INTERNATIONAL CONFERENCE ON DESIGN & TECHNOLOGY OF INTEGRATED SYSTEMS IN NANOSCALE ERA (DTIS), 2016,
  • [7] A Tunable CMOS Read-out Integrated Circuit for Carbon Nanotube-based Bio-Sensors
    Lee, George Yu-Heng
    Ren, Saiyu
    Kim, Sang Nyon
    Naik, Rajesh R.
    [J]. 2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 1074 - 1077
  • [8] High-Accuracy Impedance Read-out Circuit for BIA-type Biomedical Sensors
    Chua-Chin Wang
    Pang-Yen Lou
    Tsung-Yi Tsai
    I-Yu Huang
    Yu-Cheng Lin
    Tzung-Je Lee
    Guan-Ru Chen
    [J]. Circuits, Systems, and Signal Processing, 2021, 40 : 4187 - 4195
  • [9] High-Accuracy Impedance Read-out Circuit for BIA-type Biomedical Sensors
    Wang, Chua-Chin
    Lou, Pang-Yen
    Tsai, Tsung-Yi
    Huang, I-Yu
    Lin, Yu-Cheng
    Lee, Tzung-Je
    Chen, Guan-Ru
    [J]. CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2021, 40 (09) : 4187 - 4195
  • [10] System-level simulation of microbolometer and read-out integrated circuit
    Chen Chao
    Jiang YaDong
    Zhang Long
    Zhou Yun
    Zheng Xing
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2015, 58 (05) : 907 - 915