Improved reliability of perfusion estimation in dynamic susceptibility contrast MRI by using the arterial input function from dynamic contrast enhanced MRI

被引:0
|
作者
Tseng, Chih-Hsien [1 ,2 ,3 ,4 ,5 ,6 ]
Jaspers, Jaap [3 ,4 ,5 ,6 ,7 ]
Romero, Alejandra Mendez [3 ,4 ,5 ,6 ,7 ]
Wielopolski, Piotr [8 ]
Smits, Marion [2 ,8 ,9 ]
van Osch, Matthias J. P. [2 ,3 ,4 ,5 ,6 ,10 ]
Vos, Frans [1 ,2 ,3 ,4 ,5 ,6 ,8 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Med Delta, Delft, Netherlands
[3] Erasmus MC, Holland Proton Therapy Ctr Consortium, Rotterdam, Netherlands
[4] Holland Proton Therapy Ctr, Delft, Netherlands
[5] Leiden Univ, Med Ctr, Leiden, Netherlands
[6] Delft Univ Technol, Delft, Netherlands
[7] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Dept Radiotherapy, Rotterdam, Netherlands
[8] Univ Med Ctr Rotterdam, Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[9] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Brain Tumour Ctr, Rotterdam, Netherlands
[10] Leiden Univ, CJ Gorter MRI Ctr, Med Ctr, Dept Radiol, Leiden, Netherlands
关键词
arterial input function; cerebral blood flow; cerebral blood volume; dynamic contrast enhanced MRI; dynamic susceptibility contrast MRI; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; AUTOMATIC SELECTION; AGENT CONCENTRATION; HIGH-GRADE; VOLUME; QUANTIFICATION; OXYGEN;
D O I
10.1002/nbm.5038
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The arterial input function (AIF) plays a crucial role in estimating quantitative perfusion properties from dynamic susceptibility contrast (DSC) MRI. An important issue, however, is that measuring the AIF in absolute contrast-agent concentrations is challenging, due to uncertainty in relation to the measured R-2(*)-weighted signal, signal depletion at high concentration, and partial-volume effects. A potential solution could be to derive the AIF from separately acquired dynamic contrast enhanced (DCE) MRI data. We aim to compare the AIF determined from DCE MRI with the AIF from DSC MRI, and estimated perfusion coefficients derived from DSC data using a DCE-driven AIF with perfusion coefficients determined using a DSC-based AIF. AIFs were manually selected in branches of the middle cerebral artery (MCA) in both DCE and DSC data in each patient. In addition, a semi-automatic AIF-selection algorithm was applied to the DSC data. The amplitude and full width at half-maximum of the AIFs were compared statistically using the Wilcoxon rank-sum test, applying a 0.05 significance level. Cerebral blood flow (CBF) was derived with different AIF approaches and compared further. The results showed that the AIFs extracted from DSC scans yielded highly variable peaks across arteries within the same patient. The semi-automatic DSC-AIF had significantly narrower width compared with the manual AIFs, and a significantly larger peak than the manual DSC-AIF. Additionally, the DCE-based AIF provided a more stable measurement of relative CBF and absolute CBF values estimated with DCE-AIFs that were compatible with previously reported values. In conclusion, DCE-based AIFs were reproduced significantly better across vessels, showed more realistic profiles, and delivered more stable and reasonable CBF measurements. The DCE-AIF can, therefore, be considered as an alternative AIF source for quantitative perfusion estimations in DSC MRI. DCE-based AIFs are reproduced significantly better across vessels and provide more stable relative CBF measurements, and can therefore improve the reliability of perfusion parameter estimations from DSC MRI. In addition, absolute CBF maps estimated with DCE-AIFs are highly correlated with previously reported values. The DCE-driven AIF can, therefore, be considered as an alternative AIF source when deriving absolute CBF in DSC MRI. image
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Prognostication of anaplastic astrocytoma patients: application of contrast leakage information of dynamic susceptibility contrast-enhanced MRI and dynamic contrast-enhanced MRI
    Hee Soo Kim
    Se Lee Kwon
    Seung Hong Choi
    Inpyeong Hwang
    Tae Min Kim
    Chul-Kee Park
    Sung-Hye Park
    Jae-Kyung Won
    Il Han Kim
    Soon Tae Lee
    [J]. European Radiology, 2020, 30 : 2171 - 2181
  • [32] Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities
    Knutsson, Linda
    Stahlberg, Freddy
    Wirestam, Ronnie
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2010, 23 (01) : 1 - 21
  • [33] Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities
    Linda Knutsson
    Freddy Ståhlberg
    Ronnie Wirestam
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2010, 23 : 1 - 21
  • [34] Uncertainty estimation in dynamic contrast-enhanced MRI
    Garpebring, Anders
    Brynolfsson, Patrik
    Yu, Jun
    Wirestam, Ronnie
    Johansson, Adam
    Asklund, Thomas
    Karlsson, Mikael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 992 - 1002
  • [35] Repeatability of Cerebral Perfusion Using Dynamic Susceptibility Contrast MRI in Glioblastoma Patients
    Jafari-Khouzani, Kourosh
    Emblem, Kyrre E.
    Kalpathy-Cramer, Jayashree
    Bjornerud, Atle
    Vangel, Mark G.
    Gerstner, Elizabeth R.
    Schmainda, Kathleen M.
    Paynabar, Kamran
    Wu, Ona
    Wen, Patrick Y.
    Batchelor, Tracy
    Rosen, Bruce
    Stufflebeam, Steven M.
    [J]. TRANSLATIONAL ONCOLOGY, 2015, 8 (03): : 137 - 146
  • [36] Automated Determination of Arterial Input Function for Dynamic Susceptibility Contrast MRI from Regions around Arteries Using Independent Component Analysis
    Chen, Sharon
    Tyan, Yu-Chang
    Lai, Jui-Jen
    Chang, Chin-Ching
    [J]. RADIOLOGY RESEARCH AND PRACTICE, 2016, 2016
  • [37] Arterial input functions in dynamic susceptibility contrast MRI (DSC-MRI) in longitudinal evaluation of brain metastases
    Starck, Lea
    Skeie, Bente Sandvei
    Bartsch, Hauke
    Gruner, Renate
    [J]. ACTA RADIOLOGICA, 2023, 64 (03) : 1166 - 1174
  • [38] Dynamic Contrast-Enhanced MRI in Mice at High Field: Estimation of the Arterial Input Function Can be Achieved by Phase Imaging
    Fruytier, A. -C.
    Magat, J.
    Colliez, F.
    Jordan, B.
    Cron, G.
    Gallez, B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 544 - 550
  • [39] Dynamic susceptibility contrast MRI of gliomas
    Aronen, HJ
    Perkiö, J
    [J]. NEUROIMAGING CLINICS OF NORTH AMERICA, 2002, 12 (04) : 501 - +
  • [40] ARTERIAL SPIN LABELING PERFUSION AND DYNAMIC SUSCEPTIBILITY CONTRAST PERFUSION MRI IN POSTTREATMENT MALIGNANT GLIOMA EVALUATION
    Damek, Denise M.
    Ney, Douglas E.
    Borges, Manuel T.
    Colantoni, William
    Bert, Robert
    [J]. NEURO-ONCOLOGY, 2012, 14 : 126 - 127