Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities

被引:86
|
作者
Knutsson, Linda [1 ]
Stahlberg, Freddy [1 ,2 ]
Wirestam, Ronnie [1 ]
机构
[1] Lund Univ, Univ Lund Hosp, Dept Med Radiat Phys, S-22185 Lund, Sweden
[2] Lund Univ, Univ Lund Hosp, Dept Diagnost Radiol, S-22185 Lund, Sweden
基金
瑞典研究理事会;
关键词
Perfusion; Cerebral blood flow; Dynamic susceptibility contrast MRI; Arterial input function; Quantification; CEREBRAL-BLOOD-FLOW; ARTERIAL INPUT FUNCTION; BOLUS-TRACKING MRI; SINGULAR-VALUE DECOMPOSITION; INDEPENDENT COMPONENT ANALYSIS; SIGNAL-TO-NOISE; POSITRON-EMISSION-TOMOGRAPHY; HIGH-RESOLUTION MEASUREMENT; MEAN TRANSIT-TIME; ENHANCED MRI;
D O I
10.1007/s10334-009-0190-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Absolute quantification of cerebral blood flow, cerebral blood volume and mean transit time is desirable in the determination of tissue viability thresholds and tissue at risk in acute ischaemic stroke, as well as in cases where a global reduction in cerebral blood flow is expected, for example, in patients with dementia or depressive disorders. Absolute values are also useful when comparing sequential examinations of tissue perfusion parameters, for example, in the monitoring and follow-up of various kinds of therapy. Regardless of the method employed, a number of assumptions and approximations must be made to obtain absolute measures of perfusion. Furthermore, the different stages of data acquisition and processing are associated with various degrees of uncertainty. In this review, the problems of particular relevance to absolute quantification of cerebral perfusion parameters using dynamic susceptibility contrast magnetic resonance imaging are discussed, and possible solutions are outlined.
引用
收藏
页码:1 / 21
页数:21
相关论文
共 50 条
  • [1] Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities
    Linda Knutsson
    Freddy Ståhlberg
    Ronnie Wirestam
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2010, 23 : 1 - 21
  • [2] Dynamic Susceptibility Contrast MRI with a Prebolus Contrast Agent Administration Design for Improved Absolute Quantification of Perfusion
    Knutsson, Linda
    Lindgren, Emelie
    Ahlgren, Andre
    van Osch, Matthias J. P.
    Bloch, Karin Markenroth
    Surova, Yulia
    Stahlberg, Freddy
    van Westen, Danielle
    Wirestam, Ronnie
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 996 - 1006
  • [3] Pitfalls and Artifacts in Dynamic Susceptibility Contrast MR Perfusion of Brain
    Mangla, R.
    Ekholm, S.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [4] Non-parametric deconvolution using Bezier curves for quantification of cerebral perfusion in dynamic susceptibility contrast MRI
    Chakwizira, Arthur
    Ahlgren, Andre
    Knutsson, Linda
    Wirestam, Ronnie
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (05) : 791 - 804
  • [5] Comparison of dynamic susceptibility contrast-MRI perfusion quantification methods in the presence of delay and dispersion
    Maan, Bianca
    Simoes, Rita Lopes
    Meijer, Frederick J. A.
    Renema, W. Klaas Jan
    Slump, Cornelis H.
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [6] Absolute quantification of perfusion by dynamic susceptibility contrast MRI using Bookend and VASO steady-state CBV calibration: a comparison with pseudo-continuous ASL
    Lindgren, Emelie
    Wirestam, Ronnie
    Bloch, Karin Markenroth
    Ahlgren, Andre
    van Osch, Matthias J. P.
    van Westen, Danielle
    Surova, Yulia
    Stahlberg, Freddy
    Knutsson, Linda
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (06) : 487 - 499
  • [7] Absolute quantification of perfusion by dynamic susceptibility contrast MRI using Bookend and VASO steady-state CBV calibration: a comparison with pseudo-continuous ASL
    Emelie Lindgren
    Ronnie Wirestam
    Karin Markenroth Bloch
    André Ahlgren
    Matthias J. P. van Osch
    Danielle van Westen
    Yulia Surova
    Freddy Ståhlberg
    Linda Knutsson
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 487 - 499
  • [8] Diffusion-weighted MRI, dynamic susceptibility contrast MRI and ultrasound perfusion quantification of denervated muscle in rabbits
    G. Goyault
    G. Bierry
    N. Holl
    B. Lhermitte
    J. L. Dietemann
    J. P. Beregi
    S. Kremer
    [J]. Skeletal Radiology, 2012, 41 : 33 - 40
  • [9] Diffusion-weighted MRI, dynamic susceptibility contrast MRI and ultrasound perfusion quantification of denervated muscle in rabbits
    Goyault, G.
    Bierry, G.
    Holl, N.
    Lhermitte, B.
    Dietemann, J. L.
    Beregi, J. P.
    Kremer, S.
    [J]. SKELETAL RADIOLOGY, 2012, 41 (01) : 33 - 40
  • [10] Absolute Quantification of Cerebral Blood Flow in Neurologically Normal Volunteers: Dynamic-Susceptibility Contrast MRI-Perfusion Compared With Computed Tomography (CT)-Perfusion
    Ziegelitz, Doerthe
    Starck, Goran
    Mikkelsen, Irene K.
    Tullberg, Mats
    Edsbagge, Mikael
    Wikkelso, Carsten
    Forssell-Aronson, Eva
    Holtas, Stig
    Knutsson, Linda
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 56 - 65