Technical note: Simulation of lung counting applications using Geant4

被引:1
|
作者
Jutila, Henri [1 ,2 ]
Greenlees, Paul [1 ,2 ]
Torvela, Tiina [3 ]
Muikku, Maarit [3 ]
机构
[1] Univ Jyvaskyla, Dept Phys, Accelerator Lab, FI-40014 Jyvaskyla, Finland
[2] Univ Helsinki, Helsinki Inst Phys, POB 64, FI-00014 Helsinki, Finland
[3] STUK Radiat & Nucl Safety Author, Jokiniemenkuja 1, Vantaa 01370, Finland
关键词
Lung counting; Voxel phantom; Geant4; simulation; Low-energy gamma-ray spectra;
D O I
10.1016/j.ejmp.2023.102573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a qualitative comparison of the results of the simulation with an experiment. Experimental data were measured from a plastic phantom with a set of lungs containing 241Am activity. For comparison, simulations in which 241Am activity was uniformly distributed inside the lungs of the ICRP adult reference computational phantom were made. The attenuation of photons by the chest wall was simulated and from this photopeak ef-ficiency and photon transmission were calculated as a function of photon energy. The transmission of 59.5 keV gamma rays, characteristic of the decay of 241Am, was determined from the computational phantom as a function of the angular position of the detector. It was found that the simulated detector response corresponds well with that from an experiment. The simulated count rate below 100 keV was 10.0(7) % greater compared to the experimental measurement. It was observed that 58.3(4) % of photons are attenuated for energies below 100 keV by the chest wall. In the simulation, the transmission of 59.5 keV gamma rays varied from 13.8(2) % to 38.0(4) % as a function of the angular position of the detector. The results obtained from the simulations show a satisfactory agreement with experimental data and the package can be used in the development of future body counting applications and enables optimization of the detection geometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
    Arce, P.
    Bolst, D.
    Bordage, M-c
    Brown, J. M. C.
    Cirrone, P.
    Cortes-Giraldo, M. A.
    Cutajar, D.
    Cuttone, G.
    Desorgher, L.
    Dondero, P.
    Dotti, A.
    Faddegon, B.
    Fedon, C.
    Guatelli, S.
    Incerti, S.
    Ivanchenko, V
    Konstantinov, D.
    Kyriakou, I
    Latyshev, G.
    Le, A.
    Mancini-Terracciano, C.
    Maire, M.
    Mantero, A.
    Novak, M.
    Omachi, C.
    Pandola, L.
    Perales, A.
    Perrot, Y.
    Petringa, G.
    Quesada, J. M.
    Ramos-Mendez, J.
    Romano, F.
    Rosenfeld, A. B.
    Sarmiento, L. G.
    Sakata, D.
    Sasaki, T.
    Sechopoulos, I
    Simpson, E. C.
    Toshito, T.
    Wright, D. H.
    MEDICAL PHYSICS, 2021, 48 (01) : 19 - 56
  • [42] Application of the Geant4 PIXE implementation for space missions New models for PIXE simulation with Geant4
    Weidenspointner, Georg
    Pia, Maria Grazia
    Zoglauer, Andreas
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2152 - +
  • [43] Recent Developments on PIXE Simulation with Geant4
    Pia, M. G.
    Weidenspointner, G.
    Angelli, M.
    Quintieri, L.
    Saracco, P.
    Sudhakar, M.
    Zoglauer, A.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2066 - +
  • [44] Geant4 Simulation for LHC Radiation Monitoring
    Glaser, M.
    Guatelli, S.
    Mascialino, B.
    Moll, M.
    Pia, M. G.
    Ravotti, F.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1470 - 1472
  • [45] Simulation of nuclear resonance fluorescence in Geant4
    Jordan, David V.
    Warren, Glen A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1185 - 1190
  • [46] The Geant4 object oriented simulation toolkit
    Pia, MG
    HIGH ENERGY PHYSICS 99, PROCEEDINGS, 2000, : 1024 - 1026
  • [47] The CLAS12 Geant4 simulation
    Ungaro, M.
    Angelini, G.
    Battaglieri, M.
    Burkert, V. D.
    Carman, D. S.
    Chatagnon, P.
    Contalbrigo, M.
    Defurne, M.
    De Vita, R.
    Duran, B.
    Fair, R.
    Garcon, M.
    Ghoshal, P.
    Rajput-Ghoshal, R.
    Gotra, Y.
    Joosten, S.
    Kim, A.
    Lersch, D.
    Markov, N.
    Mestayer, M. D.
    Miller, R.
    Mirazita, M.
    Newton, J.
    Niccolai, S.
    Phelps, W.
    Procureur, S.
    Prok, Y.
    Puckett, A.
    Sokhan, D.
    Stepanyan, S.
    Vlassov, A.
    Wang, R.
    Wiggins, C.
    Ziegler, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 959
  • [48] Geant4 Simulation for Education in Medical Application
    Murakami, K.
    Amako, K.
    Jacquemier, J.
    Maire, M.
    Yoshida, H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2444 - +
  • [49] FullSimLight: ATLAS standalone Geant4 simulation
    Bandieramonte, Marilena
    Bianchi, Riccardo Maria
    Boudreau, Joseph
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [50] Investigation of Geant4 Simulation of Electron Backscattering
    Basaglia, Tullio
    Han, Min Cheol
    Hoff, Gabriela
    Kim, Chan Hyeong
    Kim, Sung Hun
    Pia, Maria Grazia
    Saracco, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (04) : 1805 - 1812