摘要
A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a qualitative comparison of the results of the simulation with an experiment. Experimental data were measured from a plastic phantom with a set of lungs containing 241Am activity. For comparison, simulations in which 241Am activity was uniformly distributed inside the lungs of the ICRP adult reference computational phantom were made. The attenuation of photons by the chest wall was simulated and from this photopeak ef-ficiency and photon transmission were calculated as a function of photon energy. The transmission of 59.5 keV gamma rays, characteristic of the decay of 241Am, was determined from the computational phantom as a function of the angular position of the detector. It was found that the simulated detector response corresponds well with that from an experiment. The simulated count rate below 100 keV was 10.0(7) % greater compared to the experimental measurement. It was observed that 58.3(4) % of photons are attenuated for energies below 100 keV by the chest wall. In the simulation, the transmission of 59.5 keV gamma rays varied from 13.8(2) % to 38.0(4) % as a function of the angular position of the detector. The results obtained from the simulations show a satisfactory agreement with experimental data and the package can be used in the development of future body counting applications and enables optimization of the detection geometry.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [31] Three Dimensional Simulation of ITER Machine by Using Geant4
    Mohammad Mehdi Nasseri
    Journal of Fusion Energy, 2016, 35 : 621 - 625
  • [32] ARGO-YBJ detector simulation using GEANT4
    Guo Yi-Qing
    Zhang Xue-Yao
    Zhang Jian-Li
    Hu Hong-Bo
    Zha Min
    He Hui-Hai
    Feng Zhao-Yang
    Wu Chao-Yong
    Wang Bo
    Zhang Yi
    Surdo, A.
    Lu Hong
    CHINESE PHYSICS C, 2010, 34 (05) : 555 - 559
  • [33] Simulation of the response of a PIPS detector using GEANT4 code
    Diaz-Frances, J. A.
    Cortes-Giraldo, M. A.
    Jimenez-Ramos, M. C.
    Hurtado-Bermudez, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 875 : 21 - 26
  • [34] Three Dimensional Simulation of ITER Machine by Using Geant4
    Nasseri, Mohammad Mehdi
    JOURNAL OF FUSION ENERGY, 2016, 35 (04) : 621 - 625
  • [35] Technical Note: GATE-RTion: a GATE/Geant4 release for clinical applications in scanned ion beam therapy
    Grevillot, L.
    Boersma, D. J.
    Fuchs, H.
    Aitkenhead, A.
    Elia, A.
    Bolsa, M.
    Winterhalter, C.
    Vidal, M.
    Jan, S.
    Pietrzyk, U.
    Maigne, L.
    Sarrut, D.
    MEDICAL PHYSICS, 2020, 47 (08) : 3675 - 3681
  • [36] ARGO-YBJ detector simulation using GEANT4
    郭义庆
    张学尧
    张建立
    胡红波
    查敏
    何会海
    冯朝阳
    吴超勇
    王博
    张毅
    A. Surdo
    卢红
    Chinese Physics C, 2010, 34 (05) : 555 - 559
  • [37] NORTH AMERICAN MEDICAL PHYSICS APPLICATIONS OF THE GEANT4 SIMULATION TOOLKIT
    Perl, Joseph
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 807 - 814
  • [38] Simulation study for a single TOF scintillator using GEANT4
    Zhang, LM
    Peng, HP
    Zhang, ZP
    Chen, HF
    Shao, M
    Wu, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (07) : N54 - N57
  • [39] Distributed Geant4 Simulation in Medical and Space Science Applications using DIANE framework and the GRID
    Moscicki, JT
    Guatelli, S
    Mantero, A
    Pia, MG
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 327 - 331
  • [40] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12