All-Suture Anchor Repair of the Flexor Digitorum Profundus Insertion: A Biomechanical Comparison of 2 Suturing Techniques

被引:0
|
作者
Belyea, Christopher M. [2 ,3 ]
Abbasi, Pooyan [2 ]
Sanghavi, Kavya K. [2 ]
Giladi, Aviram M. [2 ]
Means Jr, Kenneth R. [1 ,2 ,4 ]
机构
[1] MedStar Union Mem Hosp, Curtis Natl Hand Ctr, Baltimore, MD USA
[2] Walter Reed Natl Mil Med Ctr, Dept Orthopaed Surg, Bethesda, MD USA
[3] Uniformed Serv Univ Hlth Sci, Dept Surg, Bethesda, MD USA
[4] MedStar Union Mem Hosp, Curtis Natl Hand Ctr, 3333 North Calvert St,Suite 200, Baltimore, MD 21218 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2023年 / 48卷 / 12期
关键词
All-suture anchor; flexor digitorum profundus; jersey finger; Krackow; tendon avulsion; TENDON INJURIES; AVULSION; STRENGTH; REATTACHMENT; DIVISION; FAILURE;
D O I
10.1016/j.jhsa.2022.05.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose We compared 2 suturing techniques for reattachment of the flexor digitorum pro-fundus (FDP) via all-suture anchor.Methods We used fresh, matched-pair, cadaveric hands. We disarticulated the fingers at the proximal interphalangeal joints, preserving the proximal FDP. We released the FDPs at their distal insertion and placed an all-suture, 1.0-mm anchor at the center of each FDP footprint. Each anchor's sutures were used to reattach each FDP using 1 of 2 techniques: group H (n = 14) via horizontal mattress; group H + K (n = 12) via horizontal mattress with knots thrown and, with each suture tail, 3 proximal, running-locking, Krackow-type passes on the radial and ulnar FDP sides with the suture ends tied together. We excluded 2 specimens from the H + K group because of improper anchor placement. All other fingers in both groups were individually mounted in an MTS machine for FDP loading in the following sequence for 500 cycles each: (1) to 15 N to simulate passive motion forces; (2) to 19 N for short-arc active motion forces; and (3) to 28 N for full active motion forces. Specimens that had not failed during cyclic testing were then loaded to failure. We measured FDP-to-bone gapping via a digital transducer. We defined failure as >3-mm gapping.Results The H + K group had significantly less gapping during cyclic loading up to 19 N and significantly higher load to failure. The H + K group failed exclusively at the anchor-bone level; the H group failed mostly by suture-tendon pullout.Conclusions The H + K group performed significantly better regarding cyclic and load-to-failure testing after FDP reattachment. Clinical relevance The H + K technique combines the benefits of horizontal-mattress tendon-to-bone apposition and Krackow-tendon locking. It converts the point of failure to the bone level rather than the suture-tendon level. Copyright (c) 2023 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1276e1 / 1276e7
页数:7
相关论文
共 50 条
  • [31] Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley
    Pike, Jeffrey M.
    Gelberman, Richard H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (09): : 1523 - 1527
  • [32] Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors
    Otto, Alexander
    Mehl, Julian
    Obopilwe, Elifho
    Cote, Mark
    Lacheta, Lucca
    Scheiderer, Bastian
    Imhoff, Andreas B.
    Mazzocca, Augustus D.
    Siebenlist, Sebastian
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (10): : 2478 - 2483
  • [33] Zone I flexor digitorum profundus repair:: An ex vivo biomechanical analysis of tendon to bone repair in cadavera
    Dovan, TT
    Gelberman, RH
    Kusano, N
    Calcaterra, M
    Silva, MJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (02): : 258 - 266
  • [34] Flexor digitorum profundus with or without flexor digitorum superficialis tendon repair in acute Zone 2B injuries
    Sadek, Ahmed F.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (10) : 1034 - 1044
  • [35] Comparison of Clinical Outcomes and Computed Tomography Analysis for Tunnel Diameter After Arthroscopic Bankart Repair With the All-Suture Anchor and the Biodegradable Suture Anchor
    Lee, Jae-Hoo
    Park, In
    Hyun, Hwan-Sub
    Kim, Sang-Woo
    Shin, Sang-Jin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (05): : 1351 - 1358
  • [36] Rotator cuff repair with all-suture anchor enhances biomechanical properties and tendon-bone integration in a rabbit model
    Yu, Chengxuan
    Sun, Luyi
    Gao, Han
    Sheng, Huaixuan
    Feng, Xinting
    Yang, Xing
    Li, Jianbo
    Kong, Qingjun
    Hao, Yuefeng
    Feng, Sijia
    Chen, Jun
    HELIYON, 2024, 10 (18)
  • [37] Biomechanical Comparison of All-Suture, All-Inside Meniscus Repair Devices in a Human Cadaveric Meniscus Model
    Massey, Patrick A.
    Scalisi, Wayne
    Montgomery, Carver
    Daily, Drayton
    Robinson, James
    Solitro, Giovanni F.
    CARTILAGE, 2024,
  • [38] Biomechanical Comparison of Knotless All-Suture Anchors and Knotted All-Suture Anchors in Type II SLAP Lesions: A Cadaveric Study
    Nolte, Philip-C.
    Midtgaard, Kaare S.
    Ciccotti, Michael
    Miles, Jon W.
    Tanghe, Kira K.
    Lacheta, Lucca
    Millett, Peter J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (08): : 2094 - 2102
  • [39] Arthroscopic Repair of Posterior Root Tears of the Lateral Meniscus with All-Suture Anchor
    Familiari, Filippo
    Palco, Michelangelo
    Russo, Raffaella
    Moatshe, Gilbert
    Simonetta, Roberto
    ARTHROSCOPY TECHNIQUES, 2022, 11 (05): : E781 - E787
  • [40] A BIOMECHANICAL COMPARISON OF TECHNIQUES OF FLEXOR TENDON REPAIR
    WAGNER, WF
    CARROLL, C
    STRICKLAND, JW
    HECK, DA
    TOOMBS, JP
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (06): : 979 - 983