Short-term percutaneous mechanical circulatory support: no promise without positioning!

被引:2
|
作者
Balthazar, Tim [1 ,2 ]
Van Mieghem, Nicolas M. [3 ]
Raes, Matthias [2 ]
Van Loo, Ines [1 ]
Verbrugge, Frederik H. [1 ,2 ,4 ]
机构
[1] Univ Hosp Brussels, Ctr Cardiovasc Dis, Laarbeeklaan 101, B-1090 Jette, Belgium
[2] Univ Hosp Brussels, Dept Intens Care, Laarbeeklaan 101, B-1090 Jette, Belgium
[3] Erasmus MC, Dept Cardiol, NL-3015 CN Rotterdam, Netherlands
[4] Vrije Univ Brussel, Fac Med & Pharm, Laarbeeklaan 101, B-1090 Jette, Belgium
关键词
Cardiogenic shock; Heart-assist devices; Haemolysis; VENTRICULAR ASSIST DEVICE; HEMOLYSIS;
D O I
10.1093/ehjacc/zuad097
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Short-term percutaneous mechanical circulatory support by a micro-axial flow pump is increasingly used to support the left ventricle in cardiogenic shock. After a correct indication and placement, appropriate device management in the cardiac intensive care unit is vital to ensure optimal pump function and adequate haemodynamic support. A key element hereby is a correct percutaneous ventricular assist device (pVAD) position. This review explains how an optimal left-sided pVAD position can be achieved and maintained, focusing on the correct insertion depth and rotational angle. Useful imaging techniques, placement and replacement manoeuvres, and monitoring options through the console are discussed. The frequently encountered problem of mal-rotation towards the mitral valve, which may cause suction alarms, haemolysis, aortic regurgitation, and inadequate haemodynamic support, is explained. Finally, a practical bedside approach to assess pVAD position and discern suction alarms due to mal-positioning from haemodynamic problems is proposed. Graphical Abstract Integrative approach to percutaneous ventricular assist device (pVAD) position monitoring in the cardiac intensive care unit. First, one must evaluate whether the motor current (green waveform) is pulsatile. Very poor native heart contractility may cause a non-pulsatile motor current. Otherwise, a lack of pulsatility indicates that the inlet and outlet of the micro-axial flow pump are within the same heart chamber. In case of an overly deep insertion, both the placement signal (red waveform) and the left ventricular pressure waveform (white waveform) show a ventricular signal. When the pVAD is dislocated towards the ascending aorta, both the placement signal and the left ventricular pressure waveform demonstrate an arterial waveform. If the motor current is pulsatile, the shape of the left ventricular pressure waveform and its relationship with the aortic waveform on the placement signal are evaluated. When the systolic part of the ventricular waveform is at or above the level of the placement signal, but a decrease in the left ventricular diastolic pressure is observed, the problem is ventricular preload. When preload decreases further, this may lead to diastolic suction alarms when the pressure drops below -40 mmHg. If, on the other hand, the ventricular systolic pressure is incongruent and beneath the level of the placement signal, it indicates a problematic positioning. Echocardiography is needed to evaluate the exact type of abnormality. When motor speed is increased in such cases, a continuous suction alarm is created. LV, left ventricle; pVAD, percutaneous ventricular assist device.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 50 条
  • [31] Ambulatory short-term mechanical circulatory support: facilitates recovery and prepares patients for definitive therapy
    Raman, Jaishankar
    Saxena, Pankaj
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 39 (SUPPL 1) : 73 - 79
  • [32] Has Short-Term Mechanical Circulatory Support an Impact on Post-Heart Transplant Vasoplegia?
    Sandoval, E.
    Perdomo, J.
    Pereda, D.
    Quintana, E.
    Navarro, R.
    Fernandez-Cisneros, A.
    Ascaso, M.
    Ibanez, C.
    Arguis, M.
    Castella, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S260 - S260
  • [33] Minimally invasive apical cannulation and cannula design for short-term mechanical circulatory support devices
    Szekely, Marcell
    Ruttkay, Tamas
    Suhai, Ferenc Imre
    Bona, Aron
    Merkely, Bela
    Szekely, Laszlo
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [34] Midterm Outcomes of Bridge-to-Recovery Patients After Short-Term Mechanical Circulatory Support
    Cheng, Yi-Tso
    Garan, Arthur R.
    Sanchez, Joseph
    Kurlansky, Paul
    Ando, Masahiko
    Cevasco, Marisa
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Naka, Yoshifumi
    Takayama, Hiroo
    Takeda, Koji
    ANNALS OF THORACIC SURGERY, 2019, 108 (02): : 524 - 530
  • [35] Perioperative Management of Patients Receiving Short-term Mechanical Circulatory Support with the Transvalvular Heart Pump
    Wu, Isaac Y.
    Wyrobek, Julie A.
    Naka, Yoshifumi
    Dickstein, Marc L.
    Glance, Laurent G.
    ANESTHESIOLOGY, 2022, 136 (05) : 829 - 842
  • [36] Challenges in optimal bridge to transplantation strategy using short-term mechanical circulatory support devices
    Giordanino, Elian F.
    CLINICAL TRANSPLANTATION, 2020, 34 (10)
  • [37] Ambulatory short-term mechanical circulatory support: facilitates recovery and prepares patients for definitive therapy
    Jaishankar Raman
    Pankaj Saxena
    Indian Journal of Thoracic and Cardiovascular Surgery, 2023, 39 : 73 - 79
  • [38] Infectious complications associated with short-term mechanical circulatory support in urgent heart transplant candidates
    Solla-Buceta, Miguel
    Gonzalez-Vilchez, Francisco
    Almenar-Bonet, Luis
    Luis Lambert-Rodriguez, Jose
    Segovia-Cubero, Javier
    Gonzalez-Costello, Jose
    Delgado, Juan F.
    Perez-Villa, Felix
    Crespo-Leiro, Maria G.
    Rangel-Sousa, Diego
    Martinez-Selles, Manuel
    Rabago-Juan-Aracil, Gregorio
    De-la-Fuente-Galan, Luis
    Blasco-Peiro, Teresa
    Hervas-Sotomayor, Daniela
    Garrido-Bravo, Iris P.
    Mirabet-Perez, Sonia
    Muniz, Javier
    Barge-Caballero, Eduardo
    REVISTA ESPANOLA DE CARDIOLOGIA, 2022, 75 (02): : 141 - 149
  • [39] National survey on short-term circulatory and/or respiratory support in 2009
    Baufreton, C.
    Brochet, A.
    Darrieutort, H.
    Chretien, J. -M.
    Schinkel, E. Parot
    Tanguy, M.
    Dalmayrac, E.
    Lehot, J. -J.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 (04): : 220 - 224
  • [40] Relief of the left ventricle during short-term circulatory support
    Schibilsky, David
    Beyersdorf, Friedhelm
    Siepe, Matthias
    Benk, Christoph
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2022, 36 (06): : 385 - 388