Short-term percutaneous mechanical circulatory support: no promise without positioning!

被引:2
|
作者
Balthazar, Tim [1 ,2 ]
Van Mieghem, Nicolas M. [3 ]
Raes, Matthias [2 ]
Van Loo, Ines [1 ]
Verbrugge, Frederik H. [1 ,2 ,4 ]
机构
[1] Univ Hosp Brussels, Ctr Cardiovasc Dis, Laarbeeklaan 101, B-1090 Jette, Belgium
[2] Univ Hosp Brussels, Dept Intens Care, Laarbeeklaan 101, B-1090 Jette, Belgium
[3] Erasmus MC, Dept Cardiol, NL-3015 CN Rotterdam, Netherlands
[4] Vrije Univ Brussel, Fac Med & Pharm, Laarbeeklaan 101, B-1090 Jette, Belgium
关键词
Cardiogenic shock; Heart-assist devices; Haemolysis; VENTRICULAR ASSIST DEVICE; HEMOLYSIS;
D O I
10.1093/ehjacc/zuad097
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Short-term percutaneous mechanical circulatory support by a micro-axial flow pump is increasingly used to support the left ventricle in cardiogenic shock. After a correct indication and placement, appropriate device management in the cardiac intensive care unit is vital to ensure optimal pump function and adequate haemodynamic support. A key element hereby is a correct percutaneous ventricular assist device (pVAD) position. This review explains how an optimal left-sided pVAD position can be achieved and maintained, focusing on the correct insertion depth and rotational angle. Useful imaging techniques, placement and replacement manoeuvres, and monitoring options through the console are discussed. The frequently encountered problem of mal-rotation towards the mitral valve, which may cause suction alarms, haemolysis, aortic regurgitation, and inadequate haemodynamic support, is explained. Finally, a practical bedside approach to assess pVAD position and discern suction alarms due to mal-positioning from haemodynamic problems is proposed. Graphical Abstract Integrative approach to percutaneous ventricular assist device (pVAD) position monitoring in the cardiac intensive care unit. First, one must evaluate whether the motor current (green waveform) is pulsatile. Very poor native heart contractility may cause a non-pulsatile motor current. Otherwise, a lack of pulsatility indicates that the inlet and outlet of the micro-axial flow pump are within the same heart chamber. In case of an overly deep insertion, both the placement signal (red waveform) and the left ventricular pressure waveform (white waveform) show a ventricular signal. When the pVAD is dislocated towards the ascending aorta, both the placement signal and the left ventricular pressure waveform demonstrate an arterial waveform. If the motor current is pulsatile, the shape of the left ventricular pressure waveform and its relationship with the aortic waveform on the placement signal are evaluated. When the systolic part of the ventricular waveform is at or above the level of the placement signal, but a decrease in the left ventricular diastolic pressure is observed, the problem is ventricular preload. When preload decreases further, this may lead to diastolic suction alarms when the pressure drops below -40 mmHg. If, on the other hand, the ventricular systolic pressure is incongruent and beneath the level of the placement signal, it indicates a problematic positioning. Echocardiography is needed to evaluate the exact type of abnormality. When motor speed is increased in such cases, a continuous suction alarm is created. LV, left ventricle; pVAD, percutaneous ventricular assist device.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 50 条
  • [21] Hemolysis during short-term mechanical circulatory support: from pathophysiology to diagnosis and treatment
    Balthazar, Tim
    Bennett, Johan
    Adriaenssens, Tom
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 477 - 488
  • [22] Short-Term Mechanical Circulatory Support Over 65 Years. Is It Worth the Effort?
    Sandoval, E.
    Sbraga, F.
    Eixeres, A.
    Villar, S.
    Perez Guillen, M.
    Morales-Rey, I.
    Garcia Alcalde, L.
    Perez de la Sota, E.
    Sarralde, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S278 - S278
  • [23] Determination of Brain Death in Patients Undergoing Short-Term Mechanical Circulatory Support Devices
    Migdady, Ibrahim
    Shoskes, Aaron
    Amin, Moein
    Cho, Sung-Min
    Rae-Grant, Alexander
    George, Pravin
    HEART LUNG AND CIRCULATION, 2022, 31 (02): : 239 - 245
  • [24] Mobilization and Physiotherapy of Patients with a Levitronix CentriMag® Short-Term Mechanical Circulatory Support Device
    Bindoff, C.
    Dean, R.
    Bashford, A.
    Hards, R.
    Dreyfus, G.
    Khaghani, A.
    Birks, E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S280 - S281
  • [25] Short-term mechanical circulatory support in adults with congenital heart disease: indications and outcomes
    Abdulelah, Z.
    Constantine, A.
    Zuanetti, G.
    Frederiks, P.
    Guglielmi, G.
    Hoschtitzky, A.
    Shore, D.
    Aw, T. C.
    Dimopoulos, K.
    Bianchi, P.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [26] Short-term mechanical circulatory support in adults with congenital heart disease: indications and outcomes
    Abdulelah, Z.
    Constantine, A.
    Zuanetti, G.
    Frederiks, P.
    Guglielmi, G.
    Hoschtitzky, A.
    Shore, D.
    Aw, T. C.
    Dimopoulos, K.
    Bianchi, P.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [27] Managing Patients With Short-Term Mechanical Circulatory Support JACC Review Topic of the Week
    Balthazar, Tim
    Vandenbriele, Christophe
    Verbrugge, Frederik H.
    Den Uil, Corstiaan
    Engstroem, Annemarie
    Janssens, Stefan
    Rex, Steffen
    Meyns, Bart
    Van Mieghem, Nicolas
    Price, Susanna
    Adriaenssens, Tom
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (09) : 1243 - 1256
  • [28] Neurological Complications during Short-Term Circulatory Support
    Le Guennec, L.
    Schmidt, M.
    Brechot, N.
    Lebreton, G.
    Leprince, P.
    Combes, A.
    Luyt, C. -E.
    REANIMATION, 2016, 25 (04): : S150 - S160
  • [29] Minimally invasive apical cannulation and cannula design for short-term mechanical circulatory support devices
    Marcell Székely
    Tamás Ruttkay
    Ferenc Imre Suhai
    Áron Bóna
    Béla Merkely
    László Székely
    BMC Cardiovascular Disorders, 22
  • [30] National Trends in the Utilization of Short-Term Mechanical Circulatory Support Incidence, Outcomes, and Cost Analysis
    Stretch, Robert
    Sauer, Christopher M.
    Yuh, David D.
    Bonde, Pramod
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (14) : 1407 - 1415