Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study

被引:15
|
作者
Zhao, Yaoyu [1 ,2 ,3 ]
Liao, Yilin [1 ,2 ,3 ]
Wu, Xinyu [1 ,2 ]
Zhang, Yufeng [1 ,2 ,4 ]
Shi, Bin [3 ]
Yan, Qi [1 ,2 ,3 ,5 ]
机构
[1] Wuhan Univ, State Key Lab Breeding Base Basic Sci Stomatol Hub, Wuhan, Peoples R China
[2] Wuhan Univ, Hosp Stomatol, Sch, Key Lab Oral Biomed, Wuhan, Peoples R China
[3] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, Wuhan, Peoples R China
[4] Wuhan Univ, Med Res Inst, Sch Med, Wuhan, Peoples R China
[5] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 237 Luoyu Rd, Wuhan 430079, Peoples R China
关键词
Dental implant; Robot-guided surgery; Fiducial marker; In vitro study; Computer assisted implant surgery; Edentulous jaw; COMPUTER-AIDED SURGERY; REGISTRATION; NAVIGATION; PLACEMENT;
D O I
10.1016/j.jdent.2023.104529
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms.Methods: Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers.Results: Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 +/- 0.19 mm) and apex (0.59 +/- 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers.Conclusion: In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy.Clinical Significance: The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.
引用
收藏
页数:6
相关论文
共 48 条
  • [41] Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti-Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
    Puljic, Dario
    Celebic, Asja
    Kovacic, Ines
    Petricevic, Nikola
    APPLIED SCIENCES-BASEL, 2024, 14 (05):
  • [42] THE EFFECT OF NUMBER AND DISTRIBUTION OF TRANSFER IN IMPLANT-RETAINED MAXILLARY UNSPLINTED MAXILLARY IMPLANTS ON THE LOAD OVERDENTURES: AN IN VITRO STUDY
    Damghani, Sahar
    Masri, Radi
    Driscoll, Carl F.
    Romberg, Elaine
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (06): : 358 - 365
  • [43] Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study
    Song, Young Woo
    Yoo, Seung Ha
    Jung, Ui-Won
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (01): : 1 - 11
  • [44] Effect of artificial landmarks of the prefabricated auxiliary devices located at different arch positions on the accuracy of complete-arch edentulous digital implant scanning: An in-vitro study
    Wu, Hio Kuan
    Chen, Guanhui
    Zhang, Zhengchuan
    Lin, Xiaoxuan
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    JOURNAL OF DENTISTRY, 2024, 140
  • [45] The Effect of Different Socket Morphologies of a Maxillary Central Incisor on the Accuracy of Immediate Implants Placed With Freehand or Guided Surgery-An In Vitro Study
    Pruthi, Gunjan
    Judge, Roy
    Abduo, Jaafar
    Ngo, Luan
    Gergely, Attila
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [46] The Influence of Surgical Experience and Bone Density on the Accuracy of Static Computer-Assisted Implant Surgery in Edentulous Jaws Using a Mucosa-Supported Surgical Template with a Half-Guided Implant Placement Protocol-A Randomized Clinical Study
    Kivovics, Marton
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    MATERIALS, 2020, 13 (24) : 1 - 12
  • [47] Consumer vs. High-End 3D Printers for Guided Implant Surgery-An In Vitro Accuracy Assessment Study of Different 3D Printing Technologies
    Wegmueller, Lukas
    Halbeisen, Florian
    Sharma, Neha
    Kuehl, Sebastian
    Thieringer, Florian M.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (21)
  • [48] Effect of prefabricated immediate interim prosthesis design and insertion workflow on seating accuracy on implants placed via static computer-assisted implant surgery: A cross-sectional in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (03) : 571 - 580