Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study

被引:15
|
作者
Zhao, Yaoyu [1 ,2 ,3 ]
Liao, Yilin [1 ,2 ,3 ]
Wu, Xinyu [1 ,2 ]
Zhang, Yufeng [1 ,2 ,4 ]
Shi, Bin [3 ]
Yan, Qi [1 ,2 ,3 ,5 ]
机构
[1] Wuhan Univ, State Key Lab Breeding Base Basic Sci Stomatol Hub, Wuhan, Peoples R China
[2] Wuhan Univ, Hosp Stomatol, Sch, Key Lab Oral Biomed, Wuhan, Peoples R China
[3] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, Wuhan, Peoples R China
[4] Wuhan Univ, Med Res Inst, Sch Med, Wuhan, Peoples R China
[5] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 237 Luoyu Rd, Wuhan 430079, Peoples R China
关键词
Dental implant; Robot-guided surgery; Fiducial marker; In vitro study; Computer assisted implant surgery; Edentulous jaw; COMPUTER-AIDED SURGERY; REGISTRATION; NAVIGATION; PLACEMENT;
D O I
10.1016/j.jdent.2023.104529
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms.Methods: Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers.Results: Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 +/- 0.19 mm) and apex (0.59 +/- 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers.Conclusion: In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy.Clinical Significance: The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.
引用
收藏
页数:6
相关论文
共 48 条
  • [31] Effect of the level of alveolar atrophy on implant placement accuracy in guided surgery for full-arch restorations supported by four implants: an in vitro study
    Gocmen, Gokhan
    Bayrakcioglu, Ahmet
    Bayram, Ferit
    HEAD & FACE MEDICINE, 2023, 19 (01)
  • [32] Effect of the level of alveolar atrophy on implant placement accuracy in guided surgery for full-arch restorations supported by four implants: an in vitro study
    Gökhan Göçmen
    Ahmet Bayrakçıoğlu
    Ferit Bayram
    Head & Face Medicine, 19
  • [33] Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study
    Wang, Wenxue
    Xu, Hao
    Mei, Dongmei
    Zhou, Chen
    Li, Xiaojing
    Han, Ze'yu
    Zhou, Xiaobin
    Li, Xin
    Zhao, Baodong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 309 - 316
  • [34] Accuracy evaluation of 3D-printed noninvasive adhesive marker for dynamic navigation implant surgery in a maxillary edentulous model: An in vitro study
    Lan, Kengliang
    Tao, Baoxin
    Wang, Feng
    Wu, Yiqun
    MEDICAL ENGINEERING & PHYSICS, 2022, 103
  • [35] Accuracy of a Template-Guided Implant Surgery System with a CAD/CAM-Based Measurement Method: An In Vitro Study
    Brandt, Jan
    Brenner, Martin
    Lauer, Hans-Christoph
    Brandt, Silvia
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 328 - 334
  • [36] Effect of Bone Microstructure Derived From CBCT on the Accuracy of Robot-Assisted Implant Surgery: A Retrospective Study
    Dong, Wenxi
    Wang, Linhong
    Zheng, Yuanna
    Yang, Xulan
    Shen, Liheng
    Yang, Fan
    Zheng, Yuchen
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [37] Accuracy of static computer-assisted implant placement in long span edentulous area by novice implant clinicians: A cross-sectional in vitro study comparing fully-guided, pilot-guided, and freehand implant placement protocols
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (03) : 361 - 372
  • [38] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [39] Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (05) : 608 - 618
  • [40] Influence of guide support on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous cases using a keyless guiding system: an in vitro study
    David Kasradze
    Ricardas Kubilius
    BMC Oral Health, 25 (1)