Commandable areas of a Two-input three-level buck converter

被引:0
|
作者
Mansouri, Amirhosein [1 ]
Alenabi, Seyed Ali [1 ]
Afkar, Mohammad [1 ]
Gavagsaz-Ghoachani, Roghayeh [1 ]
Phattanasak, Matheepot [2 ]
Pierfederici, Serge [3 ]
机构
[1] Shahid Beheshti Univ, Fac Mech & Energy Engn, Tehran, Iran
[2] King Mongkuts Univ Technol North Bangkok Bangkok, Dept Teacher Training Elect Engn, Bangkok, Thailand
[3] Univ Lorraine, CNRS, LEMTA, Nancy, France
关键词
Two-modular buck; three level converter; commandability; electrolyzer;
D O I
10.1109/ONCON60463.2023.10430738
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An electrolyzer is a device which is used to produce hydrogen. This device requires a low voltage to operate. One way to reduce DC voltage is utilizing a two-input three-level buck converter. The challenge in controlling this type of converter is that sometimes the generated duty cycle located outside the interval between zero and one. Therefore, identifying the commandable areas for proper use of these converters is essential. In this article, by using the rules governing this converter and state equations, the commandable areas of the converter and its four switches have been identified by simulations results.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Three-Level Driving Method for GaN Power Transistor in Synchronous Buck Converter
    Ren, Xiaoyong
    Reusch, David
    Ji, Shu
    Zhang, Zhiliang
    Mu, Mingkai
    Lee, Fred C.
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 2949 - 2953
  • [22] Multiloop interleaved control for three-level buck converter in solar charging applications
    Zhang, Zhi
    Zhou, Hao
    Deng, Chengliang
    Song, Qinghua
    IEICE ELECTRONICS EXPRESS, 2018, 15 (11):
  • [23] Low temperature operation of a three-level Buck DC-DC converter
    Perez-Guerrero, FF
    Ray, B
    Patterson, RL
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 1415 - 1420
  • [24] A Novel Asymmetrical Three-Level BUCK (ATL BUCK) Converter for Point-of-Load (POL) Application
    Liu, Tianshu
    Wang, Hongliang
    Liu, Wenbo
    Liu, Yan-Fei
    Wang, Laili
    Danesh, Hamid
    Malcolm, Doug
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 5096 - 5101
  • [25] A New Interleaved Double-Input Three-Level Boost Converter
    Chen, Jianfei
    Hou, Shiying
    Sun, Tao
    Deng, Fujin
    Chen, Zhe
    JOURNAL OF POWER ELECTRONICS, 2016, 16 (03) : 925 - 935
  • [26] Analysis, Design and Control of an Integrated Three-Level Buck Converter under DCM Operation
    Zheng, Wen-Ming
    Zeng, Wen-Liang
    U, Chi-Wa
    Lam, Chi-Seng
    Lu, Yan
    Sin, Sai-Weng
    Wong, Man-Chung
    Martins, Rui Paulo
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2020, 29 (01)
  • [27] Buck-Boost Single-stage Three-level AC/AC Converter
    Yang, Jundong
    Li, Lei
    Yang, Kaiming
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 545 - 549
  • [28] Three-Level ZVS Active Clamping PWM for the DC-DC Buck Converter
    Rodrigues, Jean Paulo
    Mussa, Samir Ahmad
    Heldwein, Marcelo Lobo
    Perin, Arnaldo Jose
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (10) : 2249 - 2258
  • [29] Research on the magnetic integration in three-level ZCS quasi-resonant Buck converter
    Ying, Jiang
    Xiang Hui-jie
    Yang Yu-gang
    Nan, Liu
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 1948 - +
  • [30] Zero-Voltage Switching Three-Level Buck-Boost Bidirectional Converter
    Sun X.
    Yuan Y.
    Wang B.
    Li X.
    Pan Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (02): : 293 - 300