Native myocardial T1 mapping: influence of spatial resolution on quantitative results and reproducibility

被引:1
|
作者
Dalmer, Antonia [1 ]
Meinel, Felix G. [1 ]
Boettcher, Benjamin [1 ]
Manzke, Mathias [1 ]
Lorbeer, Roberto [2 ]
Weber, Marc-Andre [1 ]
Baessler, Bettina [3 ]
Klemenz, Ann-Christin [1 ]
机构
[1] Univ Med Ctr Rostock, Inst Diagnost & Intervent Radiol Pediat Radiol & N, Schillingallee 36, D-18057 Rostock, Germany
[2] Ludwig Maximilian Univ Munich, Dept Radiol, Munich, Germany
[3] Univ Hosp Wuerzburg, Inst Diagnost & Intervent Radiol, Wurzburg, Germany
关键词
Cardiac magnetic resonance imaging; reproducibility; mapping; T1; spatial resolution; REFERENCE VALUES; 3T;
D O I
10.21037/qims-23-943
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Myocardial mapping techniques can be used to quantitatively assess alterations in myocardial tissue properties. This study aims to evaluate the influence of spatial resolution on quantitative results and reproducibility of native myocardial T1 mapping in cardiac MRI.Methods: In this cross-sectional study with prospective data collection between October 2019 and February 2020, 50 healthy adults underwent two identical cardiac MRI examinations in the radiology department on the same day. T1 mapping was performed using a MOLLI 5(3)3 sequence with higher (1.4 mm x 1.4 mm) and lower (1.9 mm x 1.9 mm) in-plane spatial resolution. Global quantitative results of T1 mapping were compared between high-resolution and low-resolution acquisitions using paired t-test. Intra-class correlation coefficient (ICC) and Bland-Altman statistics (absolute and percentage differences as means +/- SD) were used for assessing test-retest reproducibility.Results: There was no significant difference between global quantitative results acquired with high vs. low resolution T1 mapping. The reproducibility of global T1 values was good for high-resolution (ICC: 0.88) and excellent for low-resolution T1 mapping (ICC: 0.95, P=0.003). In subgroup analyses, inferior test-retest reproducibility was observed for high spatial resolution in women compared to low spatial resolution (ICC: 0.71 vs. 0.91, P=0.001) and heart rates >77 bpm (ICC: 0.53 vs. 0.88, P=0.004). Apical segments had higher T1 values and variability compared to other segments. Regional T1 values for basal (ICC: 0.81 vs. 0.89, P=0.023) and apical slices (ICC: 0.86 vs. 0.92, P=0.024) showed significantly higher reproducibility in low resolution compared to high-resolution acquisitions but without differences for midventricular slice (ICC: 0.91 vs. 0.92, P=0.402).Conclusions: Based on our data, we recommend a spatial resolution on the order of 1.9 mm x 1.9 mm for native myocardial T1 mapping using a MOLLI 5(3)3 sequence at 1.5 T particularly in individuals with higher heart rates and women.
引用
收藏
页码:20 / 30
页数:11
相关论文
共 50 条
  • [21] Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold
    Weingaertner, Sebastian
    Moeller, Steen
    Schmitter, Sebastian
    Auerbach, Edward
    Kellman, Peter
    Shenoy, Chetan
    Akcakaya, Mehmet
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) : 462 - 471
  • [22] Accurate quantitative myocardial perfusion using single cycle T1 mapping
    D Chen
    B Sharif
    R Dharmakumar
    D Li
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [23] Effect of spin-lock frequency on quantitative myocardial T1ρ mapping
    Han, Caiyun
    Xu, Huimin
    Gao, Hui
    Liu, Fang
    Wu, Jian
    Liu, Yan
    Cheng, Yong
    Deng, Wei
    Yue, Xiuzheng
    Wu, Zhigang
    Yu, Yongqiang
    Zhao, Ren
    Han, Yuchi
    Li, Xiaohu
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [24] Native T1 Mapping Adding a New Dimension to the Characterization of Acute Myocardial Infarction
    Garg, Pankaj
    Plein, Sven
    CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (08)
  • [25] Native myocardial T1 mapping in pulmonary hypertension: correlations with cardiac function and hemodynamics
    Ursula Reiter
    Gert Reiter
    Gabor Kovacs
    Gabriel Adelsmayr
    Andreas Greiser
    Horst Olschewski
    Michael Fuchsjäger
    European Radiology, 2017, 27 : 157 - 166
  • [26] Native T1 Mapping and Extracellular Volume Mapping for the Assessment of Diffuse Myocardial Fibrosis in Dilated Cardiomyopathy
    Nakamori, Shiro
    Dohi, Kaoru
    Ishida, Masaki
    Goto, Yoshitaka
    Imanaka-Yoshida, Kyoko
    Omori, Taku
    Goto, Itaru
    Kumagai, Naoto
    Fujimoto, Naoki
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Yamada, Norikazu
    Sakuma, Hajime
    Ito, Masaaki
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) : 48 - 59
  • [27] Native T1 mapping for the diagnosis of Anderson-Fabry disease with myocardial hypertrophy
    Chan, Victor S. H.
    Zhou, W.
    Cheung, Stephen C. W.
    Ng, M. Y.
    HONG KONG MEDICAL JOURNAL, 2019, 25 (03)
  • [28] Clinical impact of native T1 mapping for detecting myocardial impairment in takotsubo cardiomyopathy
    Aikawa, Yukio
    Noguchi, Teruo
    Morita, Yoshiaki
    Tateishi, Emi
    Kono, Atsushi
    Miura, Hiroyuki
    Komori, Yoshiaki
    Asaumi, Yasuhide
    Fukuda, Tetsuya
    Yasuda, Satoshi
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (10) : 1147 - 1155
  • [29] Native T1 mapping to assess myocardial fibrosis in adult polycystic kidney disease
    Ng, M. Y.
    Tong, X.
    Wan, E. Y. F.
    Wang, A. Y. M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 132 - 132
  • [30] Native myocardial T1 mapping in pulmonary hypertension: correlations with cardiac function and hemodynamics
    Reiter, Ursula
    Reiter, Gert
    Kovacs, Gabor
    Adelsmayr, Gabriel
    Greiser, Andreas
    Olschewski, Horst
    Fuchsjaeger, Michael
    EUROPEAN RADIOLOGY, 2017, 27 (01) : 157 - 166