Comparison of the accuracy of dental implant placement using dynamic and augmented reality-based dynamic navigation: An in vitro study

被引:9
|
作者
Tao, Baoxin [1 ,2 ]
Fan, Xingqi [3 ]
Wang, Feng [1 ,2 ]
Chen, Xiaojun [3 ,5 ]
Shen, Yihan [1 ,2 ,4 ]
Wu, Yiqun [1 ,2 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Dent Ctr 2, Sch Med,Coll Stomatol, Shanghai, Peoples R China
[2] Shanghai Res Inst Stomatol, Natl Clin Res Ctr Oral Dis, Natl Ctr Stomatol, Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Biomed Mfg & Life Qual Engn, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Shanghai, Peoples R China
[4] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Coll Stomatol,Dept Dent Ctr 2, 280 Mohe Rd, Shanghai 201999, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Mech Engn, Dongchuan Rd 800, Shanghai 200240, Peoples R China
关键词
Surgery; Computer-assisted; Augmented reality; Dental implants; SURGERY;
D O I
10.1016/j.jds.2023.05.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Augmented reality has been gradually applied in dental implant surgery. However, whether the dynamic navigation system integrated with augmented reality technology will further improve the accuracy is still unknown. The purpose of this study is to investigate the accuracy of dental implant placement using dynamic navigation and augmented reality-based dynamic navigation systems. Materials and methods: Thirty-two cone-beam CT (CBCT) scans from clinical patients were collected and used to generate 64 phantoms that were allocated to the augmented reality based dynamic navigation (ARDN) group or the conventional dynamic navigation (DN) group. The primary outcomes were global coronal, apical and angular deviations, and they were measured after image fusion. A linear mixed model with a random intercept was used. A P value < 0.05 was considered to indicate statistical significance. Results: A total of 242 dental implants were placed in two groups. The global coronal, apical and angular deviations of the ARDN and DN groups were 1.31 +/- 0.67 mm vs. 1.18 +/- 0.59 mm, 1.36 +/- 0.67 mm vs. 1.39 +/- 0.55 mm, and 3.72 +/- 2.13(degrees) vs. 3.1 +/- 1.56(degrees), respectively. No significant differences were found with regard to coronal and apical deviations (P = 0.16 and 0.6, respectively), but the DN group had a significantly lower angular deviation than the ARDN group (P = 0.02). Conclusion: The augmented reality-based dynamic navigation system yielded a similar accuracy to the conventional dynamic navigation system for dental implant placement in coronal and apical points, but the augmented reality-based dynamic navigation system yielded a higher angular deviation. 2023 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [41] Accuracy of Dynamic Navigation for Dental Implant Placement Model-Based Evaluation (vol 42, pg 399, 2016)
    Emery, Robert W.
    Merritt, Scott A.
    Lank, Kathryn
    Gibbs, Jason D.
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (02) : 129 - 129
  • [42] The accuracy and learning curve of active and passive dynamic navigation-guided dental implant surgery: An in vitro study
    Wang, Xiao-yu
    Liu, Lin
    Guan, Miao-sheng
    Liu, Qian
    Zhao, Tong
    Li, Hong-bo
    JOURNAL OF DENTISTRY, 2022, 124
  • [43] The accuracy and learning curve of active and passive dynamic navigation-guided dental implant surgery: An in vitro study
    Wang, Xiao-Yu
    Liu, Lin
    Guan, Miao-Sheng
    Liu, Qian
    Zhao, Tong
    Li, Hong-Bo
    JOURNAL OF DENTISTRY, 2022, 124
  • [44] The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation
    Yang, Miaomiao
    Ma, Yongqing
    Han, Wenli
    Qu, Zhe
    PLOS ONE, 2024, 19 (05):
  • [45] Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: A randomized clinical trial
    Jorba-Garcia, Adria
    Bara-Casaus, Jose Javier
    Camps-Font, Octavi
    Sanchez-Garces, Maria angeles
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (05) : 438 - 449
  • [46] Implant Placement Is More Accurate Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Cullum, Daniel R.
    Sheikh, Ali
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (07) : 1377 - 1386
  • [47] Evaluation of a dynamic navigation system for training students in dental implant placement
    Zhan, Yalin
    Wang, Miaozhen
    Cheng, Xueyuan
    Li, Yi
    Shi, Xiaorui
    Liu, Feng
    JOURNAL OF DENTAL EDUCATION, 2021, 85 (02) : 120 - 127
  • [48] Dynamic navigation: a prospective clinical trial to evaluate the accuracy of implant placement
    Pellegrino, Gerardo
    Taraschi, Valerio
    Zacchino, Andrea
    Ferri, Agnese
    Marchetti, Claudio
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (02) : 139 - 147
  • [49] Augmented reality surgical navigation with accurate CBCT-patient registration for dental implant placement
    Ma, Longfei
    Jiang, Weipeng
    Zhang, Boyu
    Qu, Xiaofeng
    Ning, Guochen
    Zhang, Xinran
    Liao, Hongen
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (01) : 47 - 57
  • [50] Augmented reality surgical navigation with accurate CBCT-patient registration for dental implant placement
    Longfei Ma
    Weipeng Jiang
    Boyu Zhang
    Xiaofeng Qu
    Guochen Ning
    Xinran Zhang
    Hongen Liao
    Medical & Biological Engineering & Computing, 2019, 57 : 47 - 57