Simultaneous series and shunt earth fault detection and classification using the Clarke transform for power transmission systems under different fault scenarios

被引:2
|
作者
Esmail, Ehab M. [1 ]
Alsaif, Faisal [2 ]
Abdel Aleem, Shady H. E. [3 ]
Abdelaziz, Almoataz Y. [4 ]
Yadav, Anamika [5 ]
El-Shahat, Adel [6 ]
机构
[1] Sci Valley Acad, Valley High Inst Engn & Technol, Dept Elect Engn, Qalyubia, Egypt
[2] King Saud Univ, Coll Engn, Dept Elect Engn, Riyadh, Saudi Arabia
[3] Inst Aviat Engn & Technol, Dept Elect Engn, Giza, Egypt
[4] Future Univ Egypt, Fac Engn & Technol, Cairo, Egypt
[5] Natl Inst Technol, Dept Elect Engn, Raipur, India
[6] Purdue Univ, Sch Engn Technol, Energy Technol Program, W Lafayette, IN 47907 USA
关键词
Clarke transform; simultaneous faults; open conductor; down conductor; earth faults; high-voltage transmission lines; LOCATION;
D O I
10.3389/fenrg.2023.1208296
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For high-voltage (symmetric and non-symmetric) transmission networks, detecting simultaneous faults utilizing a single-end-based scheme is complex. In this regard, this paper suggests novel schemes for detecting simultaneous faults. The proposed schemes comprise two different stages: fault detection and identification and fault classification. The first proposed scheme needs communication links among both ends (sending and receiving) to detect and identify the fault. This communication link between both ends is used to send and receive three-phase current magnitudes for sending and receiving ends in the proposed fault detection (PFD) unit at both ends. The second proposed scheme starts with proposed fault classification (PFC) units at both ends. The proposed classification technique applies the Clarke transform on local current signals to classify the open conductor and simultaneous faults. The sign of all current Clarke components is the primary key for distinguishing between all types of simultaneous low-impedance and high-impedance faults. The fault detection time of the proposed schemes reaches 20 ms. The alternative transient program (ATP) package simulates a 500 kV-150-mile transmission line. The simulation studies are carried out to assess the suggested fault detection and identification and fault classification scheme performance under various OCFs and simultaneous earth faults in un-transposed and transposed TLs. The behavior of the proposed schemes is tested and validated by considering different fault scenarios with varying locations of fault, inception angles, fault resistance, and noise. A comparative study of the proposed schemes and other techniques is presented. Furthermore, the proposed schemes are extended to another transmission line, such as the 400 kV-144 km line. The obtained results demonstrated the effectiveness and reliability of the proposed scheme in correctly detecting simultaneous faults, low-impedance faults, and high-impedance faults.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] A modular methodology for fast fault detection and classification in power systems
    Chowdhury, FN
    Aravena, JL
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 1998, 6 (05) : 623 - 634
  • [32] Fault Detection in Transmission Lines using Instantaneous Power with ED based Fault Index
    Prasad, Ch Durga
    Srinivasu, N.
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 132 - 138
  • [33] Improved Fault Classification in Series Compensated EHV Transmission Line using Wavelet Transform and Artificial Neural Network
    Raval, Pranav D.
    Pandya, Asit S.
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [34] Effective transmission line fault detection during power swing with wavelet transform
    Lin, XN
    Liu, P
    Cheng, SJ
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1950 - 1955
  • [35] Fault detection through discrete wavelet transform in overhead power transmission lines
    Ahmed, Nadeem
    Hashmani, Ashfaq Ahmed
    Khokhar, Sohail
    Tunio, Mohsin Ali
    Faheem, Muhammad
    ENERGY SCIENCE & ENGINEERING, 2023, 11 (11) : 4181 - 4197
  • [36] A Fault Detection Technique in Transmission Line By using Discrete Wavelet Transform
    Patel, Tapas Kumar
    Panda, Prafulla Chandra
    Swain, Sarat Chandra
    Mohanty, Subodh Kumar
    PROCEEDINGS OF THE 2017 IEEE SECOND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES (ICECCT), 2017,
  • [37] A Novel Nonintrusive Fault Identification for Power Transmission Networks using Power-Spectrum-Based Hyperbolic S-transform-Part I: Fault Classification
    Chang, Hsueh-Hsien
    Nguyen Vite Linh
    Lee, Wei-Jen
    2018 IEEE/IAS 54TH INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2018,
  • [38] A Novel Nonintrusive Fault Identification for Power Transmission Networks Using Power-Spectrum-Based Hyperbolic S-Transform-Part I: Fault Classification
    Chang, Hsueh-Hsien
    Nguyen Viet Linh
    Lee, Wei-Jen
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (06) : 5700 - 5710
  • [39] Transient Inrush and Fault Current Signal Extraction Using Discrete Wavelet Transform for Detection and Classification in Shunt Capacitor Banks
    Patcharoen, Theerasak
    Ngaopitakkul, Atthapol
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (02) : 1226 - 1239
  • [40] Determination of the Earth Fault Factor in Power Systems for Different Earthed Neutrals
    Calado, M. R. A.
    Mariano, S. J. P. S.
    IEEE LATIN AMERICA TRANSACTIONS, 2010, 8 (06) : 637 - 645