Simultaneous series and shunt earth fault detection and classification using the Clarke transform for power transmission systems under different fault scenarios

被引:2
|
作者
Esmail, Ehab M. [1 ]
Alsaif, Faisal [2 ]
Abdel Aleem, Shady H. E. [3 ]
Abdelaziz, Almoataz Y. [4 ]
Yadav, Anamika [5 ]
El-Shahat, Adel [6 ]
机构
[1] Sci Valley Acad, Valley High Inst Engn & Technol, Dept Elect Engn, Qalyubia, Egypt
[2] King Saud Univ, Coll Engn, Dept Elect Engn, Riyadh, Saudi Arabia
[3] Inst Aviat Engn & Technol, Dept Elect Engn, Giza, Egypt
[4] Future Univ Egypt, Fac Engn & Technol, Cairo, Egypt
[5] Natl Inst Technol, Dept Elect Engn, Raipur, India
[6] Purdue Univ, Sch Engn Technol, Energy Technol Program, W Lafayette, IN 47907 USA
关键词
Clarke transform; simultaneous faults; open conductor; down conductor; earth faults; high-voltage transmission lines; LOCATION;
D O I
10.3389/fenrg.2023.1208296
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For high-voltage (symmetric and non-symmetric) transmission networks, detecting simultaneous faults utilizing a single-end-based scheme is complex. In this regard, this paper suggests novel schemes for detecting simultaneous faults. The proposed schemes comprise two different stages: fault detection and identification and fault classification. The first proposed scheme needs communication links among both ends (sending and receiving) to detect and identify the fault. This communication link between both ends is used to send and receive three-phase current magnitudes for sending and receiving ends in the proposed fault detection (PFD) unit at both ends. The second proposed scheme starts with proposed fault classification (PFC) units at both ends. The proposed classification technique applies the Clarke transform on local current signals to classify the open conductor and simultaneous faults. The sign of all current Clarke components is the primary key for distinguishing between all types of simultaneous low-impedance and high-impedance faults. The fault detection time of the proposed schemes reaches 20 ms. The alternative transient program (ATP) package simulates a 500 kV-150-mile transmission line. The simulation studies are carried out to assess the suggested fault detection and identification and fault classification scheme performance under various OCFs and simultaneous earth faults in un-transposed and transposed TLs. The behavior of the proposed schemes is tested and validated by considering different fault scenarios with varying locations of fault, inception angles, fault resistance, and noise. A comparative study of the proposed schemes and other techniques is presented. Furthermore, the proposed schemes are extended to another transmission line, such as the 400 kV-144 km line. The obtained results demonstrated the effectiveness and reliability of the proposed scheme in correctly detecting simultaneous faults, low-impedance faults, and high-impedance faults.
引用
收藏
页数:24
相关论文
共 50 条
  • [11] Power System Fault Detection and Classification Using Wavelet Transform and Artificial Neural Networks
    Malla, Paul
    Coburn, Will
    Keegan, Kevin
    Yu, Xiao-Hua
    ADVANCES IN NEURAL NETWORKS - ISNN 2019, PT II, 2019, 11555 : 266 - 272
  • [12] Incipient fault detection in mechanical power transmission systems
    Bhatnagar, S
    Rajagopalan, V
    Ray, A
    ACC: Proceedings of the 2005 American Control Conference, Vols 1-7, 2005, : 472 - 477
  • [13] k-NN based fault detection and classification methods for power transmission systems
    Aida Asadi Majd
    Haidar Samet
    Teymoor Ghanbari
    Protection and Control of Modern Power Systems, 2017, 2 (1)
  • [14] Fault detection and classification in transmission lines using ANFIS
    Minia University, Faculty of Engineering, Egypt, 61517, United States
    不详
    IEEJ Trans. Ind Appl., 7 (705-713): : 705 - 713
  • [15] Detection of Fault in Series Capacitor Compensated Double Circuit Transmission Line using Wavelet Transform
    Gautam, Neha
    Ali, Shoyab
    Kapoor, Gaurav
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 760 - 764
  • [16] Fault Classification of a Transmission Line using Wavelet Transform & Fuzzy Logic
    Ray, Papia
    Mishra, Debani Prasad
    Mohaptra, Spandan
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [17] Fault detection and classification in electrical power transmission system using artificial neural network
    Jamil, Majid
    Sharma, Sanjeev Kumar
    Singh, Rajveer
    SPRINGERPLUS, 2015, 4
  • [18] Transmission lines fault detection, classification and location using an intelligent Power System Stabiliser
    Othman, MF
    Mahfouf, M
    Linkens, DA
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 360 - 365
  • [19] REALTIME FAULT-DETECTION AND CLASSIFICATION IN POWER-SYSTEMS USING MICROPROCESSORS
    BARROS, J
    DRAKE, JM
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1994, 141 (04) : 315 - 322
  • [20] Fault detection and classification in transmission lines-based on wavelet transform and ANN
    Silva, K. M.
    Souza, B. A.
    Brito, N. S. D.