Simultaneous series and shunt earth fault detection and classification using the Clarke transform for power transmission systems under different fault scenarios

被引:2
|
作者
Esmail, Ehab M. [1 ]
Alsaif, Faisal [2 ]
Abdel Aleem, Shady H. E. [3 ]
Abdelaziz, Almoataz Y. [4 ]
Yadav, Anamika [5 ]
El-Shahat, Adel [6 ]
机构
[1] Sci Valley Acad, Valley High Inst Engn & Technol, Dept Elect Engn, Qalyubia, Egypt
[2] King Saud Univ, Coll Engn, Dept Elect Engn, Riyadh, Saudi Arabia
[3] Inst Aviat Engn & Technol, Dept Elect Engn, Giza, Egypt
[4] Future Univ Egypt, Fac Engn & Technol, Cairo, Egypt
[5] Natl Inst Technol, Dept Elect Engn, Raipur, India
[6] Purdue Univ, Sch Engn Technol, Energy Technol Program, W Lafayette, IN 47907 USA
关键词
Clarke transform; simultaneous faults; open conductor; down conductor; earth faults; high-voltage transmission lines; LOCATION;
D O I
10.3389/fenrg.2023.1208296
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For high-voltage (symmetric and non-symmetric) transmission networks, detecting simultaneous faults utilizing a single-end-based scheme is complex. In this regard, this paper suggests novel schemes for detecting simultaneous faults. The proposed schemes comprise two different stages: fault detection and identification and fault classification. The first proposed scheme needs communication links among both ends (sending and receiving) to detect and identify the fault. This communication link between both ends is used to send and receive three-phase current magnitudes for sending and receiving ends in the proposed fault detection (PFD) unit at both ends. The second proposed scheme starts with proposed fault classification (PFC) units at both ends. The proposed classification technique applies the Clarke transform on local current signals to classify the open conductor and simultaneous faults. The sign of all current Clarke components is the primary key for distinguishing between all types of simultaneous low-impedance and high-impedance faults. The fault detection time of the proposed schemes reaches 20 ms. The alternative transient program (ATP) package simulates a 500 kV-150-mile transmission line. The simulation studies are carried out to assess the suggested fault detection and identification and fault classification scheme performance under various OCFs and simultaneous earth faults in un-transposed and transposed TLs. The behavior of the proposed schemes is tested and validated by considering different fault scenarios with varying locations of fault, inception angles, fault resistance, and noise. A comparative study of the proposed schemes and other techniques is presented. Furthermore, the proposed schemes are extended to another transmission line, such as the 400 kV-144 km line. The obtained results demonstrated the effectiveness and reliability of the proposed scheme in correctly detecting simultaneous faults, low-impedance faults, and high-impedance faults.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Fault Classification in Transmission Systems using Wavelet Transform
    Avagaddi, Prasad
    Edward, Belwin J.
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2019, 32 (03): : 884 - 893
  • [2] FAULT DETECTION, CLASSIFICATION AND LOCATION ON TRANSMISSION LINES USING WAVELET TRANSFORM
    Reddy, B. Ravindranath
    Kumar, M. Vijaya
    Suryakalavathi, M.
    Babu, Ch. Prasanth
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 381 - 383
  • [3] Fault Detection and Classification of Shunt Compensated Transmission Line Using Discrete Wavelet Transform and Naive Bayes Classifier
    Aker, Elhadi
    Othman, Mohammad Lutfi
    Veerasamy, Veerapandiyan
    Aris, Ishak bin
    Wahab, Noor Izzri Abdul
    Hizam, Hashim
    ENERGIES, 2020, 13 (01)
  • [4] Unified fault matrix method for the calculation of shunt and series faults in power systems with complete duality of shunt and series fault matrices
    Hofmann, Lutz
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 189
  • [5] Fault detection in transmission networks of power systems
    Saha, S.
    Aldeen, M.
    Tan, C. P.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (04) : 887 - 900
  • [6] Advanced techniques for fault detection and classification in electrical power transmission systems: An overview
    Tirnovan, Radu-Adrian
    Cristea, Maria
    PROCEEDINGS OF 2019 8TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS), 2019,
  • [7] Fault detection on radial and meshed transmission systems using fast Hilbert transform
    Sharaf, AM
    ElSharkawy, RM
    Talaat, HEA
    Badr, MAL
    ELECTRIC POWER SYSTEMS RESEARCH, 1997, 41 (03) : 185 - 190
  • [8] Fault Detection on Series Capacitor Compensated Transmission Line using Walsh Hadamard Transform
    Sharma, Prachi
    Kapoor, Gaurav
    Ali, Shoyab
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 754 - 759
  • [9] Transmission Line Fault Classification Using Discrete Wavelet Transform
    Choudhury, Mousam
    Ganguly, Amrita
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [10] Comparison of Different Classification Algorithms for Fault Detection and Fault Isolation in Complex Systems
    Jung, Marcel
    Niculita, Octavian
    Skaf, Zakwan
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE IN THROUGH-LIFE ENGINEERING SERVICES, 2018, 19 : 111 - 118