Picometer measurements of strain coefficients by quadrature interferometry and lock-in amplification

被引:1
|
作者
Nilson, Alec [1 ]
Wick, Kurt [1 ]
机构
[1] Univ Minnesota, Sch Phys & Astron, Minneapolis, MN 55455 USA
关键词
LASER INTERFEROMETER;
D O I
10.1119/5.0102091
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Modulated strain displacements were measured with a quadrature Michelson-Morley interferometer employing polarization optics and two lock-in amplifiers to filter noise and thermal drift. The advantages of the technique, its limitations, and estimates on the accuracy are discussed, including an algorithm to correct for non-ideal components and non-linear effects. Instructions for the construction and setup of the quadrature interferometer are provided. To test the interferometer, the dynamic converse piezoelectric effect was used, and by modulating the electric field across the sample, the |d(14)| strain coefficient for x-cut quartz was determined to be 0.66 6 0.04 pC/N, which is within 1.5 standard deviations of the accepted standard. The measurements had a standard deviation of 4.1 pm, resulting in standard errors as low as 5 fm/V after fitting. (c) 2023 Published under an exclusive license by American Association of Physics Teachers.
引用
收藏
页码:142 / 152
页数:11
相关论文
共 50 条
  • [1] Quadrature demodulation based on lock-in amplifier technique for self-mixing interferometry displacement sensor
    Zhang, Zihua
    Li, Chengwei
    Huang, Zhen
    APPLIED OPTICS, 2019, 58 (22) : 6098 - 6104
  • [2] AC Atom Interferometry with Quantum Lock-in Sensing
    Coslovsky, Jonathan
    Afek, Gadi
    Davidson, Nir
    SLOW LIGHT, FAST LIGHT, AND OPTO- ATOMIC PRECISION METROLOGY X, 2017, 10119
  • [3] Signal measurements with lock-in amplifiers
    Lake Shore Cryotronics, United States
    Electron World, 2022, 2014 (26-29):
  • [4] Imaging through fog using quadrature lock-in discrimination
    Kumar, Shashank
    Debnath, Bapan
    Meena, M. S.
    Fade, Julien
    Dhar, Sankar
    Alouini, Mehdi
    Bretenaker, Fabien
    Ramachandran, Hema
    OSA CONTINUUM, 2021, 4 (05): : 1649 - 1657
  • [5] Sampling, Quantization and Computational Aspects of the Quadrature Lock-In Amplifier
    Leis, John
    Kelly, Christopher
    Buttsworth, David
    6TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATION SYSTEMS (ICSPCS'2012), 2012,
  • [6] Photoacoustic Remote Sensing Microscopy with Lock-In Amplification
    Shi, Wei
    Hajireza, Parsin
    Bell, Kevan
    Zemp, Roger
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [7] Lock-in Amplification for Implantable Multiwavelength Pulse Oximeters
    Theodor, Michael
    Karakas, Utku
    Ruh, Dominic
    Zappe, Hans
    Seifert, Andreas
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 495 - 498
  • [8] Lock-in detector for telecommunication cable measurements
    Owczarek, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11A): : 204 - 206
  • [9] CMOS integrator based lock-in pixel for heterodyne interferometry
    Soloviev, O
    Vdovin, G
    VLSI CIRCUITS AND SYSTEMS II, PTS 1 AND 2, 2005, 5837 : 945 - 952
  • [10] Pulsed laser interferometry with sub-picometer resolution using quadrature detection
    Shao, Lei
    Gorman, Jason J.
    OPTICS EXPRESS, 2016, 24 (15): : 17459 - 17469