AC Atom Interferometry with Quantum Lock-in Sensing

被引:1
|
作者
Coslovsky, Jonathan [1 ]
Afek, Gadi [1 ]
Davidson, Nir [1 ]
机构
[1] Weizmann Inst Sci, Dept Phys Complex Syst, IL-76100 Rehovot, Israel
关键词
Cold atoms; Atom interferometry; Quantum lock-in;
D O I
10.1117/12.2257344
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes a technique that allows measurement of very small alternating accelerations. It is based on a quantum version of a lock-in amplifier, 1 which filters out spectral components far from the frequency of the measured signal, improving the signal-to-noise ratio of the measurement. As a proof-of-principle, a controlled experiment using microwave radiation is performed, modulating the phase of the control pulses at a given frequency. A strong response at twice the modulation frequency is observed as expected. Preliminary results of measurements taken with Raman control are also presented, in which a controlled modulation of the phase was obtained by modulating a piezoelectric actuator, causing one of the Raman mirrors to vibrate.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Quantum lock-in force sensing using optical clock Doppler velocimetry
    Ravid Shaniv
    Roee Ozeri
    Nature Communications, 8
  • [2] Quantum lock-in force sensing using optical clock Doppler velocimetry
    Shaniv, Ravid
    Ozeri, Roee
    NATURE COMMUNICATIONS, 2017, 8
  • [3] Quantum double lock-in amplifier
    Chen, Sijie
    Zhuang, Min
    Fang, Ruihuang
    Chen, Yun
    Han, Chengyin
    Lu, Bo
    Huang, Jiahao
    Lee, Chaohong
    COMMUNICATIONS PHYSICS, 2024, 7 (01):
  • [4] Lock-in amplifier for portable sensing systems
    Aguirre, J.
    Medrano, N.
    Calvo, B.
    Celma, S.
    ELECTRONICS LETTERS, 2011, 47 (21) : 1172 - U27
  • [5] CMOS integrator based lock-in pixel for heterodyne interferometry
    Soloviev, O
    Vdovin, G
    VLSI CIRCUITS AND SYSTEMS II, PTS 1 AND 2, 2005, 5837 : 945 - 952
  • [6] Dual Open Atom Interferometry for Compact and Mobile Quantum Sensing
    Ben-Aïcha, Yosri
    Mehdi, Zain
    Freier, Christian
    Szigeti, Stuart S.
    Wigley, Paul B.
    Conlon, Lorcán O.
    Husband, Ryan
    Legge, Samuel
    Eagle, Rhys H.
    Hope, Joseph J.
    Robins, Nicholas P.
    Close, John D.
    Hardman, Kyle S.
    Haine, Simon A.
    Thomas, Ryan J.
    Physical Review Letters, 2024, 133 (26)
  • [7] A LOW-COST LOCK-IN AMPLIFIER FOR AC POLAROGRAPHY
    UTHMAN, AP
    WOODWARD, WS
    REILLEY, CN
    CHEMICAL BIOMEDICAL AND ENVIRONMENTAL INSTRUMENTATION, 1982, 12 (03): : 151 - 169
  • [8] The role of lock-in phase setting in ac susceptibility measurement
    Drobac, D.
    Marohnic, Z.
    Zivkovic, I.
    Prester, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (05):
  • [9] Photoacoustic Remote Sensing Microscopy with Lock-In Amplification
    Shi, Wei
    Hajireza, Parsin
    Bell, Kevan
    Zemp, Roger
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [10] INSTRUMENTATION FOR AC VOLTAMMETRY BASED ON A DIGITAL LOCK-IN AMPLIFIER
    CURRAN, DJ
    KINGSLEY, ED
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 183 (MAR): : 14 - ANYL