Determination of pioglitazone hydrochloride by flow injection chemiluminescence tris(2,2′-bipyridyl)ruthenium(II)-silver(III) complex system

被引:1
|
作者
Rehman, Habib Ur [1 ,2 ]
Kakar, Attiq Ur Rehman [2 ]
Yaqoob, Mohammed [2 ,3 ]
Asghar, Muhammad [2 ]
Ahmed, Syed Saeed [2 ]
Nisa, Khair Un [2 ]
机构
[1] Baluchistan Residential Coll Turbat, Kech, Pakistan
[2] Univ Balochistan, Dept Chem, Quetta, Pakistan
[3] Univ Balochistan, Dept Chem, Sariab Rd, Quetta 87300, Pakistan
关键词
chemiluminescence; DPA; flow injection analysis; pharmaceutical formulations; pioglitazone hydrochloride; Ru(bipy)(3)(2+); MECHANISM; DIPERIODATOARGENTATE(III); CHROMATOGRAPHY; FORMULATIONS; GLIMEPIRIDE; OXIDATION; METFORMIN; BULK; HPLC;
D O I
10.1002/bio.4420
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flow injection-chemiluminescence (FI-CL) approach is proposed for the assay of pioglitazone hydrochloride (PG-HCl) based on its enhancing influence on the tris(2,2 '-bipyridyl)ruthenium(II)-silver(III) complex (Ru(bipy)(3)(2+)-DPA) CL system in sulfuric acid medium. The possible CL reaction mechanism is discussed with CL and ultraviolet (UV) spectra. The optimum experimental conditions were found as: Ru(bipy)(3)(2+), 5.0 x 10(-5) M; sulfuric acid, 1.0 x 10(-3) M; diperiodatoargentate(III) (DPA), 1.0 x 10(-4) M; potassium hydroxide, 1.0 x 10(-3) M; flow rate 4.0 ml min(-1) for each flow stream and sample loop volume, 180 mu l. The CL intensity of PG-HCl was linear in the range of 1.0 x 10(-3) to 5.0 mg L-1 (R-2 = 0.9998, n = 10) with limit of detection [LOD, signal-to-noise ratio (S/N) = 3] of 2.2 x 10(-4) mg L-1, limit of quantification (LOQ, S/N = 10) of 6.7 x 10(-4) mg L-1, relative standard deviation (RSD) of 1.0 to 3.3% and sampling rate of 106 h(-1). The methodology was satisfactorily used to quantify PG-HCl in pharmaceutical tablets with recoveries ranging from 93.17 to 102.77 and RSD from 1.9 to 2.8%.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 50 条
  • [41] Determination of trimethylamine in fish by capillary electrophoresis with electrogenerated tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection
    Li, Ming
    Lee, Sang Hak
    LUMINESCENCE, 2007, 22 (06) : 588 - 593
  • [42] Electrochemiluminescence of tris(2,2′-bipyridyl)ruthenium(II)/pyruvate system in the absence of cerium(III)
    Han, Shuang
    Li, Haijuan
    Hu, Lianzhe
    Yuan, Yali
    Xu, Guobao
    ANALYTICAL METHODS, 2010, 2 (05) : 479 - 483
  • [43] Determination of glyphosate mono-isopropylamine salt in process samples using flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection
    Adcock, JL
    Barnett, NW
    Gerardi, RD
    Lenehan, CE
    Lewis, SW
    TALANTA, 2004, 64 (02) : 534 - 537
  • [44] Flow injection fluorimetric determination of chromium(VI) in electroplating baths by luminescence quenching of tris(2,2′-bipyridyl) ruthenium(II)
    Hassan, SSM
    Abdel-Shafi, AA
    Mohammed, AHK
    TALANTA, 2005, 67 (04) : 696 - 702
  • [45] Tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescent determination of ethyl formate
    Tadesse Haile Fereja
    Shimeles Addisu Kitte
    Dmytro Snizhko
    Liming Qi
    Anaclet Nsabimana
    Zhongyuan Liu
    Guobao Xu
    Analytical and Bioanalytical Chemistry, 2018, 410 : 6779 - 6785
  • [46] Tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescent determination of ethyl formate
    Fereja, Tadesse Haile
    Kitte, Shimeles Addisu
    Snizhko, Dmytro
    Qi, Liming
    Nsabimana, Anaclet
    Liu, Zhongyuan
    Xu, Guobao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (26) : 6779 - 6785
  • [47] Solid-supported chemiluminescence and electrogenerated chemiluminescence based on a tris(2,2′-bipyridyl)ruthenium(II) derivative
    Greenway, GM
    Greenwood, A
    Watts, P
    Wiles, C
    CHEMICAL COMMUNICATIONS, 2006, (01) : 85 - 87
  • [48] CHEMILUMINESCENCE DETECTION USING REGENERABLE TRIS(2,2'-BIPYRIDYL)RUTHENIUM(II) IMMOBILIZED IN NAFION
    DOWNEY, TM
    NIEMAN, TA
    ANALYTICAL CHEMISTRY, 1992, 64 (03) : 261 - 268
  • [49] Electrogenerated chemiluminescence based on tris(2,2′-bipyridyl) ruthenium(II) with hydroxyl carboxylic acid
    Chen, X
    Chen, W
    Jiang, YQ
    Jia, L
    Wang, XR
    MICROCHEMICAL JOURNAL, 1998, 59 (03) : 427 - 436
  • [50] Solid-state Electrogenerated Chemiluminescence Based on Semiconductor Nanocrystals and Tris(2,2′-bipyridyl) Ruthenium(II) Complex
    Kargbo, Osman
    Ding, Shou-Nian
    Li, Qi-Le