A novel flow injection-chemiluminescence (FI-CL) approach is proposed for the assay of pioglitazone hydrochloride (PG-HCl) based on its enhancing influence on the tris(2,2 '-bipyridyl)ruthenium(II)-silver(III) complex (Ru(bipy)(3)(2+)-DPA) CL system in sulfuric acid medium. The possible CL reaction mechanism is discussed with CL and ultraviolet (UV) spectra. The optimum experimental conditions were found as: Ru(bipy)(3)(2+), 5.0 x 10(-5) M; sulfuric acid, 1.0 x 10(-3) M; diperiodatoargentate(III) (DPA), 1.0 x 10(-4) M; potassium hydroxide, 1.0 x 10(-3) M; flow rate 4.0 ml min(-1) for each flow stream and sample loop volume, 180 mu l. The CL intensity of PG-HCl was linear in the range of 1.0 x 10(-3) to 5.0 mg L-1 (R-2 = 0.9998, n = 10) with limit of detection [LOD, signal-to-noise ratio (S/N) = 3] of 2.2 x 10(-4) mg L-1, limit of quantification (LOQ, S/N = 10) of 6.7 x 10(-4) mg L-1, relative standard deviation (RSD) of 1.0 to 3.3% and sampling rate of 106 h(-1). The methodology was satisfactorily used to quantify PG-HCl in pharmaceutical tablets with recoveries ranging from 93.17 to 102.77 and RSD from 1.9 to 2.8%.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 50 条
  • [31] Tris (2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence in Analytical Science
    Lee, Won-Yong
    Mikrochimica Acta, 1997, 127 (01): : 19 - 39
  • [32] Tris (2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence in analytical science
    Lee, WY
    MIKROCHIMICA ACTA, 1997, 127 (1-2) : 19 - 39
  • [33] Tris (2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence in analytical science
    Won-Yong Lee
    Microchimica Acta, 1997, 127 : 19 - 39
  • [34] Flow-Injection Chemiluminescent Determination of Piroxicam Using Tris (2,2'-bipyridyl) Ruthenium(II)Potassium Permanganate System
    Yu, Fengshan
    Chen, Fang
    Zheng, Shishi
    Chen, Lanhua
    Cui, Man
    ANALYTICAL LETTERS, 2008, 41 (13) : 2412 - 2423
  • [35] Determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl) ruthenium(II) chemiluminescence detection respectively
    Anastos, N
    Barnett, NW
    Lewis, SW
    Gathergood, N
    Scammells, PJ
    Sims, DN
    TALANTA, 2005, 67 (02) : 354 - 359
  • [36] Selective determination of acenaphthylene by flow injection analysis with tris(2,2′-bipyridine)ruthenium(II) chemiluminescence detection
    Li, Ming
    Lee, Sang Hak
    TALANTA, 2007, 74 (02) : 265 - 270
  • [37] Flow injection chemiluminescent determination of arniodarone in pharmaceutical preparations using photogenerated tris(2,2′-bipyridyl)ruthenium(III)
    Perez-Ruiz, Tomas
    Martinez-Lozano, Carmen
    Martin, Jesus
    Ruiz, Encarna
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (01) : 143 - 147
  • [38] Flow injection chemiluminescent determination of N-nitrosodimethylamine using photogenerated tris(2,2′-bipyridyl) ruthenium (III)
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Tomás, V
    Martín, J
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 69 - 74
  • [39] Determination of total calcium in plasma by flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) electrochemiluminescent detection
    Shi, Lihong
    Liu, Xiaoqing
    Li, Haijuan
    Xu, Guobao
    ELECTROANALYSIS, 2006, 18 (16) : 1584 - 1589
  • [40] Chemiluminescence determination of sulfite in sugar and sulfur dioxide in air using tris(2,2′-bipyridyl)ruthenium(II)-permanganate system
    Meng, H
    Wu, FW
    He, ZK
    Zeng, YE
    TALANTA, 1999, 48 (03) : 571 - 577